Cecilware GB1CP manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cecilware GB1CP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cecilware GB1CP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cecilware GB1CP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cecilware GB1CP should contain:
- informations concerning technical data of Cecilware GB1CP
- name of the manufacturer and a year of construction of the Cecilware GB1CP item
- rules of operation, control and maintenance of the Cecilware GB1CP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cecilware GB1CP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cecilware GB1CP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cecilware service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cecilware GB1CP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cecilware GB1CP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Compact Cappuccino & Hot Chocolate Dispensers Models : •GB1CP •GB2CP •GB3CP •GB1HC-CP •GB2HC-CP •GB1HC-CP-PC* •GB2HC-CP-PC* GB 1HC-CP (shown) GB2 -CP (shown) Cecilware sells value... Worldwide 45 -05 20th Avenue, Long Island City, NY 11105 • 718-932-1414 FAX 718-932-7860 OPERATIONAL MANUAL NL05A-A 10/2006[...]

  • Page 2

    2 Mechanical Specifications Model # Label No. of Hoppers Hopper Capacity (lb.) Width (in.) Dept (in.) Hight (in.) Tank (gal.) GB1CP Cappuccino 1 8 lb. 7.75 18.625 26 1.5 GB2CP Cappuccino 2 4 lb. 7.75 18.625 26 1.5 GB3CP Cappuccino 3 4 lb. 10.5 18.625 26 1.5 GB1HC-CP Hot Chocolate 1 8 lb. 7.75 18.625 26 1.5 GB2HC-CP Hot Chocolate 2 4 lb. 7.75 18.625[...]

  • Page 3

    3 I. INSTALLATION INSTRUCTIONS This equipment is to be installed to com ply with the applicab le Federal, State, or l ocal plumbing cod es having jurisdictio n. In addition: 1. A quick disconnect wat er connection or en ough extra coiled tubing (at le ast 2x the depth of the unit) so that the machine can be moved for cleaning under ne ath. 2. An ap[...]

  • Page 4

    4 ADJUSTMENTS A. WATER FLOW ADJUSTMENTS, FLOW RATE The Unit Is Factory Adjusted To Dispen se Water At The Rate of 4 oz/sec. To increase or decrease fl ow, proceed as follows: 1. Remove Left side panel and loc ate Dispense Valv e mounted on tank , with Flow Adjuster facing up, underneath cold w at er reservoir. 2. Locate Flow Adjustm e nt Screw (whi[...]

  • Page 5

    5 COMPONENTS TEST A) Thermostat Adjustments: The Thermostat is factory set for proper dispense temperature of 190° F with the control shaft set to the maximum clockwise position. If field adjustments are needed proceed as follows: To DECREASE temperature, turn t he control shaft slightly in the COUNTERCLOCKWISE direction. For qualified technicians[...]

  • Page 6

    6 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electr ical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact. PROBLEM PROBABLE CAUSE REMEDY A Dispensing unit unplugged Reconnect dis[...]

  • Page 7

    7 CLEANING AND SANITIZING Sanitizing: All sanitizing agents in the food zone must comply with 21 CFR 178.1010. All food dispensing units should be sani tized periodically. All parts to be sanitized must be clean ed first. To prepare a sanitizing solution: Add 2 Tsp. Of Liquid Clorox Bleach (5.25% Concentration) To 1 gallon Of Water At Room Temperat[...]

  • Page 8

    8 INTERNAL COMPONENTS IDENTIFICATION TANK ASSEMBLY SK89Q ITEM P/N QTY DESCRIPTION 1 SK88A 1 Tank Top 2 L681A M008A 1 1 Thermostat & Probe Thermostat Knob 3 G267A MO18A 1 1 Heater 120v 1700w Gasket, Tank Heater 4 P446A 4 1/4-20x5/8 SS SL Hex Washer Hd Scr 5 M461A 6 Silicone Seal (.466 Id) 6 K525A 3 Elbow 90° Ss 7 M326A 23” Hose - Overflow 8 K[...]

  • Page 9

    9 EXTERNAL COMPONENTS IDENTIFICATION ITEM P/N QTY DESCRIPTION 10 CD65A CD66A 1 2 Chamber Mount Chamber Mount Grommet 11 CD63A CD353 1 1 Whipping Chamber Whip Blade W/2flats 12 M884A 1 Extension Tube 13 C002A 1 Pilot Light Amber, for heater 14 M172S 1 Legs 4"Adj (Set Of 4) 15 75014 75015 1 1 Molded Drip Tra y Grill 16 RE73A 1 Drip Tray Platform[...]

  • Page 10

    10[...]