Cecilware GB5MV-10-LD manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cecilware GB5MV-10-LD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cecilware GB5MV-10-LD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cecilware GB5MV-10-LD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cecilware GB5MV-10-LD should contain:
- informations concerning technical data of Cecilware GB5MV-10-LD
- name of the manufacturer and a year of construction of the Cecilware GB5MV-10-LD item
- rules of operation, control and maintenance of the Cecilware GB5MV-10-LD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cecilware GB5MV-10-LD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cecilware GB5MV-10-LD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cecilware service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cecilware GB5MV-10-LD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cecilware GB5MV-10-LD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    GB5MV-10-LD Operation Manual NL48P July 2005 GB6MP-10-LD-U GB8MP-10-LD-U[...]

  • Page 2

    CONTENTS Important Owner Information _____________________________________1 Introduction ____________________________________________________1 Important Safety Instructions ___________________________________2 Model Description _________________________ ______________________3 Specifications __________________________________________________3 Plug [...]

  • Page 3

    IMPORTANT OWNER INFORMATION Record the model number, serial number (identification plate is located behind front door), voltage and purchase date of your Cecilware Cappuccino Dispenser in the spaces below. Please have the information available when calling Cecilware for assistance. Model #: Serial #: Voltage: Date of Purchase: Business 8:30 a.m. to[...]

  • Page 4

    IMPORTANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property. IMPORTANT SAFETY INSTRUCTIONS WARNINGS The GB8MP - 10 - LD - U ( only ) is equipped with two (2) power switches and two (2) 120 volt grounded power cords. To avoid any injury, turn both power switches OFF.[...]

  • Page 5

    PLUG CONFIGURATION NEMA 5-15P NEMA 5-15R NEMA 5-15P NEMA 5-15R (2) DEDICATED OUTLETS 120 V 15 A Figure # 1 FOR GB8 MODELS ONLY MODEL DESCRIPTION GB8M P - 10 - LD - U (shown) GB5 - LD - U & GB6M P - 10 - LD - U (typical) These High Volume Cappu ccino Dispensers will hold double the amount of your most popular flavor along with up to seven other [...]

  • Page 6

    UNPACKING INSTRUCTIONS Carefully unpack the Cappucci no Dispenser Unit and inspect immediately for shipping damage. Your Cappuccino Dispenser Unit was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory. In case of damage, c ontact the shipper . DESCRIPTION AND LOCATI[...]

  • Page 7

    START - UP PROCEDURE Caution: Make sure that the Heater Switches, are in the OFF position. 1. Co nnect the ¼ inch copper waterlines to the ¼ inch flare water inlet fittings of the valves. 2. Plug the power cords into dedicated receptacles. 3. Activate the Power Switch (Toggle Up). The door display panel, the red power indicator lights and the gre[...]

  • Page 8

    TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock, DISCONNECT POWER CORDS before repairing or replacing any internal components of the unit. Before any attempt to replace a component be sure to check all electrical connections for proper connection. PROBLEM PROBABLE CAUSE REMEDY A Dispensing unit unplugged. Reconnect dispensing [...]

  • Page 9

    Model L690A (Rev. B) Dual Probe Liquid Level Controller Overview - The L690A is a Dual Probe Liquid Level Co ntroller designed to maintain a specific level of water in the tank. This device utilizes two level probes for increased reliability. Independent maximum fill timers are incorporated in the controller for overflow protection. Operation - Whe[...]

  • Page 10

    - MOVE RINSE SWITCH TO "RINSE". 2. EMPTY DRIP TRAY WASH, RINSE, AND SANITIZE* - MOVE RINSE SWITCH TO "SERVE". - PUSH AND HOLD EACH DISPENSE BUTTON 3 TO 5 SEC. - POSITION PAN UNDER DISPENSE TUBES. 1. RINSE WHIPPER CHAMBERS 4. SANITIZE* ALL EXTERIOR SURFACES. 3. EMPTY DRIP TRAY. 2. REPLACE HOPPERS, ROTATE PRODUCT GUIDES DOWN. REFI[...]

  • Page 11

    [...]

  • Page 12

    GB5MV-10-LD (VISTA) 5 Flavor Cappuccino Dispenser Door not shown PRODUCT GUIDE DRIP TRAY PAN POWER SWITCH RINSE SWITCH GRILL HOPPER (4) (CD185) 5 Lbs 5 Lbs 5 Lbs HEATER SWITCH WHIPPER CHAMBER HOPPER (1) (CD179) HEATER LIGHT 5 Lbs 10 Lbs[...]

  • Page 13

    10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD185) 10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD180) 27.0" 21.5" DRIP TRAY PAN GRILL DRIP TRAY PAN (2) GRILL SLANTED WHIPPER CHAMBER PRODUCT GUIDE HEATER LIGHT RINSE SWITCH WHIPPER CHAMBER POWER SWITCH PRODUCT GUIDE HEATER LIGHT POWER SWITCH RINSE SWITCH RIGHT SIDE HOT WATER ([...]

  • Page 14

    11 5 7 1 12 8 6 4 3 10 2 9 WHIPPER CHAMBER 13 IMPORTANT: SLANTED WHIPPER CHAMBERS (SEE BELOW) ARE NOT INTERCHANGEABLE WITH STANDARD STRAIGHT WHIPPER CHAMBERS. BE SURE TO ORDER USING THE CORRECT PART NUMBERS. SLANTED WHIPPER CHAMBER MARKING 1 2 2 1 1 4 1 2 1 1 1 1 11 2 12 1 ITEM IMPELLER (1 FLAT) USE W/ CD75A) 1 7 1 S L A N T E D 2 1 IMPELLER (2 FLA[...]

  • Page 15

    PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 HOPPER COVER AUGER MOTOR #CD175 (90 RPM)[...]

  • Page 16

    PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER[...]

  • Page 17

    BODY ASS'Y GB5MV-10-LD (Vista) DESCRIPTION ITEM QTY P/N[...]

  • Page 18

    DOOR ASS'Y GB5MV-10-LD (Vista) DESCRIPTION ITEM QTY P/N[...]

  • Page 19

    [...]

  • Page 20

    1 2 3 4 5 6 7 8 9 10 11 ITEM GB6MP GB8MP DESCRIPTION OF COMPONENTS FOR MACHINES NO. P/N QTY P/N QTY WITH MOLDED FRONT GB6MP AND GB8MP 1 SK61A 1 SK43A 1 INSIDE DOOR PANEL, UPPER DOOR 2 SK65A 1 SK45A 1 INSIDE DOOR PANEL, LOWER DOOR 3 SK60A 1 SK42A 1 DOOR HOUSING, UPPER 4 SK50A 1 SK44A 1 DOOR HOUSING, LOWER 5 M903A 1 M915A 1 MOLDED UPPER DOOR PANEL 6 [...]

  • Page 21

    DESCRIPTION ITEM QTY P/N 21[...]

  • Page 22

    DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 12" WIDE, 4.8" DEEP, 16.5" HIGH. APPROX. 3.7 GAL.[...]

  • Page 23

    DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 15" WIDE, 6" DEEP, 18" HIGH. APPROX. 6 GAL.[...]

  • Page 24

    WATER INLET VALVE AUGER DOOR UNIT WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH MAIN UNIT DISPENSE VALVE HI-LIMIT THERMOSTAT HEATER SWITCH RINSE SWITCH A2 44 NO 32 NC 22 NC 14 NO A1 43 NO 31 NC 21 NC 13 NO GND 5-15P 15A-1.7KW 5-15R POWER SWITCH L1 GND GND TANK HEATER 1.7KW L1 N RELAY L1 L1[...]

  • Page 25

    GB6M-10-LD-U[...]

  • Page 26

    GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - LEFT SIDE - 120V NE195 SHEET 1 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHTS REV A[...]

  • Page 27