A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 90MA/MF/MU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 90MA/MF/MU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier 90MA/MF/MU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier 90MA/MF/MU should contain:
- informations concerning technical data of Carrier 90MA/MF/MU
- name of the manufacturer and a year of construction of the Carrier 90MA/MF/MU item
- rules of operation, control and maintenance of the Carrier 90MA/MF/MU item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 90MA/MF/MU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 90MA/MF/MU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 90MA/MF/MU.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 90MA/MF/MU item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    62 - - 10458 - - 00 Models 90MA/MF/MU, Design Series T wo Beginning Serial Number C00400 INST ALLA TION OPERA T ION & SER VICE Marine /Industria l Sing le Packag e Cooling Unit[...]

  • Page 2

    Carr ier C orporation 2000 D Printed in U . S. A. 0700 OPERA TION AND SER VICE MANUAL MARINE/INDUSTRIAL S INGLE P ACKAGE COOLING UNIT MODELS 90MA/ MF/M U, Design Series T wo Beginning Serial Number C00400 Carr ier Transic old, Car rier C orporat ion, P .O . Box 4805, Sy rac us e, N.Y . 13221 U. S. A . Carr ier Refriger ation Operations , A member o[...]

  • Page 3

    Safe ty- 1 62 - - 10458- - 00 SA FETY S UMMA R Y GENE RAL SAF ET Y NOT I CES The following ge nera l safe ty notices supplement the specific war nings and c autions appear ing elsew here in this manual. They are recomm ended precautions t hat mu st be understood and applied during operation and maintenance of the e quipment cover ed he rein. The ge[...]

  • Page 4

    Safe ty-2 62- - 10458 - - 00 CAUTIO N Sharp edges of coil fins ar e exposed. T o pr event injury , cover top of evaporator with cardboard or a few layers of heavy tape. CAUTIO N T o avoid coil d amage, cover e vaporator fac e with plywood or other rigid sh eet mat erial. If an y coil fins are ma sh ed or ben t, stra igh ten wi th a coil fin co mb o[...]

  • Page 5

    i 62- - 10458 - - 00 T ABLE O F CONT ENTS P ARAGRAPH NUM BER Page GENERAL S AFETY NOTIC ES Safety -1 ..................................................... FIRST A ID Safet y-1 ...................................................................... OPER A TING P RE CAUTIONS Safety -1 ...................................................... MAINTENANCE [...]

  • Page 6

    ii 62- - 10458 - - 00 LIS T OF ILLU STR A TIONS FI GURE NUM BER Page Figure 1 Base Un it Interior D eta ils (T ypical) 1 ................................................ Figure 2 Unit Dimensions 5 ............................................................... Fi gur e 3 Horizont al Wheel C ent ering 5 ..............................................[...]

  • Page 7

    1 62- - 10458 - - 00 1. INT RODUCT I ON The 90M series single- - pac kage cooling units (See Figure 1) are de signed to provide air conditioning aboar d mar ine vesse ls and in industrial applica tions. The 90MA units are fitted with se a wate r c ooled conde nsers while the 90MF units are fitte d with fr esh water cooled c ondense rs. Both units a[...]

  • Page 8

    2 62- - 10458 - - 00 T abl e 1 90MA/ MF / MU Ph ysi cal Dat a - - Refri geran t 22 R - - 22 - - English U nits R- -2 2 - - Me t r i c U ni t s BASE UNIT 90MA/MF/M U UNITS Englis h ( Metr ic ) 204 206 208 212 204 206 208 212 NOMI NAL CAP ACITY T ons (k W) 3 5 7.5 10 10.5 17.6 26.4 35.1 OPERA TING WEIGHT Base Unit - - 90MA/M F Pounds (k g) 390 427 89[...]

  • Page 9

    3 62- - 10458 - - 00 T abl e 2 90MA/ MF / MU Ph ysi cal Dat a - - Refri geran t 407C R - - 407C - - Eng l ish Un i ts R - - 407C - - Met ric Un i ts BASE UNIT 90MA/MF/M U UNITS Englis h ( Metr ic ) 404 406 408 412 404 406 408 412 NOMI NAL CAP ACITY T ons (k W) 3 5 7.5 10 10.5 17.6 26.4 35.1 OPERA TING WEIGHT Base Unit - - 90MA/M F Pounds (k g) 390 [...]

  • Page 10

    4 62- - 10458 - - 00 T abl e 3 90MA/ MF Physi cal Data - - Ref rig eran t 134a R - - 134a - - Eng l ish Un i ts R - - 134a - - Metri c Uni ts BASE UNIT 90MA/M F UNITS Englis h ( Metr ic ) 308 312 308 312 NOMI NAL CAP ACITY T ons (k W) 5.5 8 19.3 28. 1 OPERA TING WEIGHT Base Unit Pounds (k g) 895 950 406 431 Dis c harge Plenum Pounds (k g) 50 50 22.[...]

  • Page 11

    5 62- - 10458 - - 00 UNIT 004 006 008,012 A B C 36.19( 919) 21.88( 556) 59.12( 1501) 48(1219) 29.62( 752) 69.50( 1765) D SEE NOTE 2 E 24(610) F G H J 13.81( 351) 13.13( 333) 0.75( 19) 12.5( 318) 16.44( 418) 15(381) 0.75( 19) 10.62( 270) 19.38( 492) 17.25( 438) 1.31( 33) 1 1.44(291) K L M N P Q R 17.06( 433) 20.50( 521) 17(432) 31.88( 810) 2.06( 52)[...]

  • Page 12

    6 62- - 10458 - - 00 90MA/M F004/ 006 UNI TS 90MU004/006 UNI T S 90MA/M U008/012 UNI T S 90MU008/012 UNI T S UNIT A* B* C* D* E F G 90MA/MF004 1/ 2 1/2 -- -- ¾ FPT -- -- -- -- 1.75 90MA/MF006 3/ 4 -- -- 3/4 -- -- -- -- (45) 90MA/MF008/012 1” 1” -- -- -- -- -- -- 90MU004 -- -- -- -- -- -- 1/2 flare 1/ 2 flare 90MU006 -- -- -- -- -- -- 1/2 flare[...]

  • Page 13

    7 62- - 10458 - - 00 T able 4 Re com me nded Line Size s, Re mote Conde nse r UNIT L ENG TH O F RUN (90MU) 0- -2 5 26 - - 50 51 - - 75 76 - - 100 ( ) DISCH LIQUID DIS CH LIQUID DISCH LIQUID DISCH LIQUID 004 1/2 (1.3) 1/2( 1.3) 5/8(1.6) 1/2(1.3) 5/8(1.6) 1/2(1.3) 7/8(2. 2) 1/2(1. 3) 006 5/8(1.6) 1/2(1.3) 7/8(2.2) 1/2(1.3) 7/8(2.2) 1/2(1.3) 7/8(2.2) [...]

  • Page 14

    8 62- - 10458 - - 00 CONTROL WIRI NG - - On extende d voltage (208/230- - v) units, the control t ransf ormer is factor y wired for 208 - - v usage . If unit is to be used on 230- - v system, reconne ct primar y wiring on transfor mer . See F igure 13 (004/006 size) or Figure 15 (008/012 siz e). On a ll units, the thermosta t is fa ctory installe d[...]

  • Page 15

    9 62- - 10458 - - 00 switch T - - HIGH to ener gize liquid line solenoid (LLS) [to acti vat e the fu ll ev apor ator coi l and all co mp resso r cylinde rs]. If thermosta t switch T- - HIG H is not calling for cooling, power flows to e ner gize compressor unloader sole noid (US) [to unloa d compr essor cyli nd ers]. Whe n room temper ature fa lls t[...]

  • Page 16

    10 62- - 10458 - - 00 BEL T TENSION ADJUSTMENT - - S hut off unit power supply . Loosen fan motor from mounting bracke t. Do not loosen motor mounting bra cke t from unit. Move f an motor up or down until proper belt ten sion is a chieve d (appr oximate ly 3/4- - in. deflec tion with 8- - pound tension a t midpoint of belt spa n). Lubri cati on - -[...]

  • Page 17

    11 62- - 10458 - - 00 c. Re gulate flow to condense r with a supply line valve. If pump is a non - - overloading type , the valve may be fully close d while pump is running. For aver age scale deposit, allow solution to remain in condenser over- night. For heavy sca le de posit, allow 24 hours. d. Drain conde nser a nd flush with clea n water . Fig[...]

  • Page 18

    12 62- - 10458 - - 00 5.1 0 Eva porator Fa n Motor Re mov al a. S hut of f unit main powe r supply . W ARNI NG Lo ck op en an d tag u ni t d is con n ect before work in g o n fan mo tor . Remov e fu ses an d tak e them wi th you after n oti n g th is on tag. CAUTIO N Before attempti n g to remove fan motors or motor mounts, pl ace a p iece of p lyw[...]

  • Page 19

    13 62- - 10458 - - 00 BASED ON DRA WI NG 50BW 400093 USED ON A 004/006 SI ZE 40.25 52.00 B 22.00 27.31 C 38.25 50.00 D 36.25 48.00 E -- 1.25 F -- 45.50 G 18.005 23.31 H -- 0.75 J -- 25.81 K 3.18 -- L 2.56 -- M 8.75 -- N 2.00 -- P 1.00 -- R 5.00 9.00 S 7.50 6.00 T 15.00 16.50 V 10.00 15.38 W 0.70 -- 008/012 SI ZE A Figure 1 2 Mounting Ba se[...]

  • Page 20

    14 62- - 10458 - - 00 TB1- - 1 R B W FOR HO T WA TER /STEAM HEA T S EE NOTE 2 ORN (SEE NOTE 3) SUPPL Y POWER T- -LOW RED X2 X1 F RED RED TB1- - 5 TB1- - 4 YEL DPS BLU ORN SW SPS CL VIO GROUND L3 L2 G BLK 24VOLT TRAN IFC BLK 11 BLK BLU YEL 13 12 13 12 23 22 BLK 21 23 22 BLU YEL BRN CHR BRN BRN BRN BRN TB1- - 3 RED IFC BRN BRN GRN 3 2 T3 T1 T2 YEL IF[...]

  • Page 21

    15 62- - 10458 - - 00 H1 CONTROLLING HEA T CONT ACTOR TRANSFORMER SUCTION PRESSURE SWI TCH INTERNAL PROTECT OR- - COMPRESSOR INDOOR F AN MOTOR INDOOR F AN CONT ACTOR BACKUP HEA T CONT ACTOR TB H2 IPC IFM IFC SPS TRAN SW TERMINAL BOARD SWITCH COMPRESSOR CONT A CTOR COMPRESSOR LOCKOUT AUTOMA TIC CUT OUT DISCHARGE PRESSURE SWI TCH AC CC CL C F DPS FUS[...]

  • Page 22

    16 62- - 10458 - - 00 TB1- - 1 T- -HIG H R R 8 BLU BLK 90MA012 UN ITS ON L Y B W ORN B W 9 IPC CD T 2 BLK US BLK BLU CD T 1 2 OLA 1 BLU 2 OLB 1 FOR HO T WA TER /STEAM HEA T S EE NOTE 2 ORN (SEE NOTE 3) SUPPL Y POWER T- -LOW RED X2 X1 F RED RED TB1- - 5 YEL DPS BLU ORN SW CHR RED SPS 1 3 RED CL RED VIO GROUND L3 L2 G SEE NOTE 1 BLK 24VOLT TRAN BLU B[...]

  • Page 23

    17 62- - 10458 - - 00 OL OVER LOAD US UNLOADER SOLENOID H1 CONTROLLI NG HEA T CONT ACTOR TRANSFORMER SUCTION PRESSURE SWI TCH INTERNAL PROTECT OR- - COMPRESSOR INDOOR F AN MOTOR INDOOR F AN CONT ACTOR BACKUP HEA T CONT ACTOR TB H2 IPC IFM IFC SPS TRAN SW TERMINAL BOARD SWITCH COMPRESSOR CONT A CTOR COMPRESSOR LOCKOUT AUTOMA TIC CUT OUT DISCHARGE PR[...]

  • Page 24

    Index - - 1 62- - 10458 - - 00 A Access P anel , 9 Accesso ry Pl enu m, 1 Air Filte r , 5, 10 C Component Arr angeme nt, 15, 17 Condensate Drain, 7, 10 Condenser , 10 Condenser Connec tions, 6 Cran kcas e Heater , 12 Cycle- - Loc, 12 E Elect ri cal Co nnect io ns , 7 Evapora tor Coil, 10 F Fan Adjustme nt, 9 Fan Motor , 12 Fan Sh af t, 5 H Hea ting[...]