Carrier 50PG03-07 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 50PG03-07, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 50PG03-07 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier 50PG03-07. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier 50PG03-07 should contain:
- informations concerning technical data of Carrier 50PG03-07
- name of the manufacturer and a year of construction of the Carrier 50PG03-07 item
- rules of operation, control and maintenance of the Carrier 50PG03-07 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 50PG03-07 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 50PG03-07, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 50PG03-07.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 50PG03-07 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    50PG03 - - - 07 Single P ackage Rooftop Units Electric Co o ling with P URON R (R - - - 410A) Refr igeran t and COMFO RT Link t Control s Installation Instructions IMPOR T ANT : Thi s i nst a ll a ti on ins tr uc ti on cont ai ns ba s ic unit installatio n in form ation in clud ing installatio n of field co ntro l devi c e s. For i nf orm at i on o[...]

  • Page 2

    2 C07269 Fig. 1 - - Roof Cur b Detai ls 50PG03 - - 07[...]

  • Page 3

    3 C07271 Fig. 2 - - Base Uni t Dime nsi ons 50PG03 - - 07[...]

  • Page 4

    4 INST ALLA TION Ste p 1 — Pr ovide U nit Support Roof Curb Assem ble o r install accessory roof curb in accord ance with instru ction s ship ped with this accesso ry . (See F ig. 1.) In stall ins ula ti on, cant s tr ips , roofi ng, and count er f la shi ng as s hown. Du ctwo rk can be installed to roo f cu rb befo re un it is set in place. Du c[...]

  • Page 5

    5 T able 1 – Physic al Dat a BASE U NIT 50PG 03 04 05 06 07 NOMI NAL C AP A CI TY (T o ns) 2 3 4 5 6 OPERA TING WEIGHT (lb) Unit* 704 704 775 829 874 Econ omizer Ve rt i ca l 40 40 40 40 40 Horizon tal 50 50 50 50 50 Hum idi-Mi Zer ™ Adap tive Dehumidi fication Sys tem 22 22 31 27 26 Roof Cur b 14-i n. 122 122 122 122 122 24-i n. 184 184 184 18[...]

  • Page 6

    6 T able 1 — Physi cal Dat a (cont ) BASE U NIT 50PG ( cont) 03 04 05 06 07 EV APORA TOR F AN Centri fu g al T ype, B elt Driv e Quantity … Size ( in.) Low 1...12 x 9 1...12 x 9 1...12 x 9 1...12 x 9 1...12 x 9 High 1...12 x 9 1...12 x 9 1...12 x 9 1...12 x 9 1...12 x 9 Ty p e D r i v e Low Bel t Belt Belt Bel t Belt High Belt Be lt Be lt Bel t[...]

  • Page 7

    7 Ste p 3 — Field Fabr icate D uct wor k On v ertical u nits, secure all du cts to roof curb an d b uild ing structu re. Do not conne ct duc twor k to unit . For hor izont al appl ic at ions, f iel d - - suppl ied f lange s shoul d be at tac hed t o hori zonta l disc har ge ope nings a nd al l ductwor k se cure d to t he fl ange s. I nsula te a n[...]

  • Page 8

    8 INSERT SIDE DRAIN PLUG FOR DOWN DRAIN USE. DRILL 5/8” DIA. (0.625 mm) HOLE THRU FOR DOWN DRAIN USE. C10321 Fig. 5 - - Condens ate Drai n Pan OPTIONAL UNIONS TO ALLOW FOR CONDENSA TE P AN REMOVAL 4" (102mm) CONDENSA TE P AN ACCES S P ANEL C06234 Fig. 6 - - Exte rnal T rap for Conde nsat e Drai n NOTE: T rap should be deep enough to offset m[...]

  • Page 9

    9 UNIT DAMAGE HAZARD Failu re to fo llow t his cau tion m ay result in eq uip men t dam age . The c orr ec t powe r phas ing is cri tic al to t he oper at ion of the scroll co mp ressors. A n in correct p hasin g will resu lt in an al ar m be ing ge nera te d and com pre ss or ope rat ion l ockout . Should thi s occur , power pha se c orr ec tion m[...]

  • Page 10

    10 T em p e r a tu re C o n t ro l The uni t can be c ontr oll ed wit h ei the r a Ca rr ier- - a pproved s pac e temp erature sen sor, a Carrier accesso ry T herm idistat t devic e, or a Carrier - - ap pro ved accesso ry therm ostat. Install the temp erature con trol d evice acco rdin g to the in stallation in structio ns in clud ed with the acces[...]

  • Page 11

    11 C07191 Fig. 13 - - Thir d Party Smoke De te ctor on Humi di- - Mi Zer t 50PG03 - - 07[...]

  • Page 12

    12 T ab le 2 – Electrica l Da ta - - U nits Witho ut O ptio na l Con ven ience O utlet UNIT 50PG NOMI NAL POWE R SUPPL Y Vo lt s - Ph- H z VOL TAGE RANGE CO MP RESSOR OF M FLA POWE R EXHAUS T FLA IFM TYPE IFM FLA ELECTRIC HEAT PO WER SUPPL Y D ISC ONNEC T SIZE Min Max RLA LRA FL A Nomi nal kW* MCA MOC P† FLA LRA 03 208/230-1-60 187 253 12.8 60 [...]

  • Page 13

    13 T ab le 2 - - Electrica l Da ta - - U nits Witho ut Optio na l Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RLA LRA FLA Nominal kW* MCA MOC P† FLA LRA 04 (cont) 208/230-3-60 187 253 1[...]

  • Page 14

    14 T ab le 2 - - Electrica l Da ta - - U nits Witho ut Optio na l Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RLA LRA FLA Nominal kW* MCA MOC P† FLA LRA 05 (cont) 460-3-60 414 506 7.1 4[...]

  • Page 15

    15 T ab le 2 - - Electrica l Da ta - - U nits Witho ut Optio na l Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RL A LRA FLA Nominal kW* MCA MOCP† FLA LR A 06 (cont) 208/230-3- 60 187 253[...]

  • Page 16

    16 T ab le 2 - - Electrica l Da ta - - U nits Witho ut Optio na l Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RL A LRA FLA Nominal kW* MCA MOCP† FLA LR A 07 (cont) 208/230-3- 60 187 253[...]

  • Page 17

    17 T ab le 3 – E lectrical Da ta - - U nits With O ptio na l Po wered Co nv enien ce Outlet UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RL A LRA FLA Nominal kW* MCA MOCP † FLA LRA 03 208/230-1- 60 187 253 12.8 60 1[...]

  • Page 18

    18 T ab le 3 - - Electrica l Da ta - - Units With O ptio na l Po wered Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RLA LRA FLA Nominal kW* MCA MOC P† FLA LRA 04 (cont) 208/230-3- 60 187[...]

  • Page 19

    19 T ab le 3 - - Electrica l Da ta - - Units With O ptio na l Po wered Co nv enien ce Ou tlet (con t) UNIT 50PG NOM INAL POWE R SUPPL Y Vo lt s -P h - Hz VOL T AGE RANG E CO MPR ESSOR OFM FLA POWE R EXHAUST FLA IFM TYPE IFM FLA ELECTRIC HEA T POWE R SUPPL Y DISCONNEC T SIZ E Min Max RLA LRA FLA Nomina l kW* MCA MOCP† FL A LRA 05 (cont ) 460-3-60 [...]

  • Page 20

    20 T ab le 3 - - Electrica l Da ta - - Units With O ptio na l Po wered Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RL A LRA FLA Nominal kW* MCA MOCP† FLA LR A 06 (cont) 208/230-3- 60 18[...]

  • Page 21

    21 T ab le 3 - - Electrica l Da ta - - Units With O ptio na l Po wered Co nv enien ce Ou tlet (con t) UNIT 50PG NOMINAL POWER SUPPL Y Volt s -P h- Hz VOL T AGE RANG E COMPRES SOR OFM FLA POWER EXHAU ST FLA IFM TYPE IFM FLA ELECTR IC HEA T POWER SUPPL Y DISCONNECT SIZE Min Ma x RL A LRA FLA Nominal kW* MCA MOCP† FLA LR A 07 (cont) 208/230-3- 60 18[...]

  • Page 22

    22 Ste p 7 — Install Outdoor Air Hoods (Units wit h Eco nomi zer) Per for m the fol lowing proc edur e to ins tal l the outdoor- - a ir hoods: 1. Economi zer a nd ba rome tr ic r eli ef hoods a re l ocat ed in the conde nse r sec tion unde r the s lant ed coi l for s hipping. ( See Fig. 14. ) Barom etr ic r el ie f/pow er e xhaus t hood is s hipp[...]