A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC 750, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC 750 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC 750. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC 750 should contain:
- informations concerning technical data of APC 750
- name of the manufacturer and a year of construction of the APC 750 item
- rules of operation, control and maintenance of the APC 750 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC 750 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC 750, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC 750.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC 750 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-1194C 07/2008 User Manual English APC Smart-UPS ® 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply[...]

  • Page 2

    [...]

  • Page 3

    1 Introduction The APC Uninterruptible Power Supply (UPS) is de signed to prev ent blackouts, brownou ts, sags, and surges from reaching y our computer an d othe r valuable electronic equipm ent. The UPS filters small utility line fluctuations an d isolates your equipment from large disturbances by internally d is- connecting from the utility line.[...]

  • Page 4

    2 Positioning the UPS Place the UPS where it will be use d. The UPS is heavy. Select a location sturd y enough to handle the weight. Do not operate the UPS where there is excessive dus t or the temperature and humidity are outside the specified limits. P LACEMENT Mounting the UPS in a Rack The UPS is h eavy. To lighten it, you may remove the batter[...]

  • Page 5

    3 Installing and Connecti ng the Battery and Attaching the Front Bezel Step 1 Step 2 Ste p 3 Ste p 4 Connect battery p lug to UPS. Tuck white battery cord into space above connect or. Connecting Equipment and Power to the UPS S MART -UPS R EAR P ANEL 100/120V Models 120V Model Only: Site wiring fault indicator 230V Models[...]

  • Page 6

    4 1. Connect equipment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer draws signific antly mo re power than other types of equipment and may overload the UPS . 2. Add any optional accessories to the Smart-Slot. 3. Using a power cord, plug the UPS into a two- pole, three-wire, grounded receptacle only. Avoid usi ng exte[...]

  • Page 7

    5 2: O PERA TION S MART -UPS F RONT P ANEL Power On Power Off Online The online LED illuminates when the UPS is supplying utilit y power to the connected equipm ent. If the LED is not lit, the UPS is either not turned ON, or is supplyin g battery power. AVR Tr im This LED illuminates to indicate th e UPS is compensating for a high utility voltage. [...]

  • Page 8

    6 Replace Battery Failure of a battery self-test ca uses the UPS to emit short beeps for one minute and t he replace batt ery LED illuminates. Refer to Trou ble- shooting in this manu al. Battery Disconnected The replace ba ttery LED flashes and short beep is emitted every two seconds to indi cate the battery is disconnect ed. Automatic Self-Test T[...]

  • Page 9

    7 3: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE OR OP TIONAL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), On Startup Only, No Self-Test This function sets the interval at [...]

  • Page 10

    8 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE OR OP TIONAL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning. PowerChute interface software provides auto- matic, unattended shut- down when approximately two minutes (by default) of battery operated run time [...]

  • Page 11

    9 4: S TOR AG E , M AINTENANCE , AND T RANSPORTING Storage Store the UP S covered a n d positi oned as for pr oper functio ning, in a c ool, dry l ocation, with t he bat- teries fully charged. At -15 to +3 0 ° C (+5 to +86 ° F), charge the UPS batt ery every si x months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three m [...]

  • Page 12

    10 5: T ROUBLESHOOTING Use the chart below to solve minor Smart-UPS installation and operation problems. Refer to the APC web site, www.apc.com , for a ssistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Battery not connected prop- erly. Check that the b attery connec tor is fully eng aged. button not [...]

  • Page 13

    11 P ROBLEM AND P OSSIBLE C AUS E S OLUTION T HE OVERLOAD LED IS LIT AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The conne cted equipment ex ceeds the spec ified “maximum load” as de- fined in Specifications at the APC web site, www.apc.com . The alarm remains on unt il the overlo ad is removed. Disconnect nonessen- tial equ[...]

  • Page 14

    12 P ROBLEM AND P OSSIBLE C AUS E S OLUTION T HERE IS NO U TILITY POWER AND THE UPS HAS BEEN TURNED OFF 120V/230V Models: When the UPS is off and there is no util ity power, use the cold star t feature t o apply power to the connected equipment from the UPS battery. Cold start is not a normal condi- tion. Press and hold the button, (for about 3 sec[...]

  • Page 15

    13 Service If the UPS requires service do not return it to the dealer. Instead, follow t hese steps: 1. Review t he problem s discussed in t he Troubl eshooting section of this manual to eliminate com- mon pro blems. 2. If the pr oblem persists, contact APC Customer Se rvice through the APC w eb site, www.apc.com / support . ! Note the m odel num b[...]

  • Page 16

    14 6: R EGULA TOR Y AND W ARRANTY I NFORMA TION Regulatory Agency Approvals a nd Radio Frequency Warnings 230V MODELS This is a Cl ass A product . In a dom estic environm ent this product may cause radio interference, in which case the user m ay be required to take corrective actions. 120V MODELS This equipment has been tested and fou nd to comply [...]

  • Page 17

    15 Declaration of Conformity Limited Warranty American Power Conversion (APC) warrants its products to be fr ee from defects in ma terials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is lim ited to repairing or replacing, at its own sole o p- tion, any such defective products. To obtain se[...]