APC 66123 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC 66123, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC 66123 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC 66123. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC 66123 should contain:
- informations concerning technical data of APC 66123
- name of the manufacturer and a year of construction of the APC 66123 item
- rules of operation, control and maintenance of the APC 66123 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC 66123 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC 66123, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC 66123.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC 66123 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Network Mana geme nt Card & Mod bus/ Jbus (66123) Installation manu al[...]

  • Page 2

    2 - 3402230800/ AC[...]

  • Page 3

    3402230800/A C - 3 The Ne twork Manage ment Card & Modbus/Jbus (66123) is reco mmended for c entral UPSs protecting entire networks or for UPS units backing up critical loads. With the car d installed, the UPS ha s its own IP address and uses the local computer capabilities to: ◗ Supply web pages (http or https (SSL)) with information on stat[...]

  • Page 4

    4 - 3402230800/ AC . ETHERNET port Servi ce port (Settings/Senso r) OVERVIEW INDICATIONS LED Colour Status Description ACT Green ◗ OF F ◗ ON ◗ Flash ing ◗ Card not conne cted to network ◗ Card connected to net work, bu t no ac tivity ◗ Port is sending/receiving 100M Orange ◗ OFF ◗ ON ◗ Port ope rating at 10 Mbits/ s ◗ Port ope r[...]

  • Page 5

    3402230800/A C - 5 The Network Management Card & Modbus/Jbus (66123) can be hot-plugged in MGE TM Galax y TM 7000 equipped with a Minislot. It is not necessary to s hutdown the UP S, disconnect the load or restart the UPS. ◗ Note the M AC address of the card before inserting it. ◗ Insert and secure the c ard with the s crews. ◗ Connect th[...]

  • Page 6

    6 - 3402230800/ AC The card is co nfig ured by defau lt wit h t his se rvice e nabled. No manual confi gurati on is requ ired.Th e IP paramet ers are aut omatical ly colle cted by the car d. From the main configuration menu: (see above) ◗ Pr ess the 2 k ey ( Net work conf igura tio n). ◗ Press t he 1 key(Read N etwork set tings). The settings s[...]

  • Page 7

    3402230800/A C - 7 To check whether the Network Management Card & Modbus/Jbus (66123) is oper ationa l after insta llation and conf igurat ion, proceed as fol lows. ◗ Run a brows er ◗ Enter in the address bar: http://IP address/ (e.g. http://172.16.1.82/) ◗ The hom e page is displayed ◗ Se t the ti me by click ing th e Time c omm and. ?[...]

  • Page 8

    8 - 3402230800/ AC The Environment sensor is a Network Mana gement Card & Modbus/ Jbus option. The sensor remotely monitors the UP S environment by regularly measuring the temperature and humidity, and checking the states of two external conta cts. It can al so send alarms (e-mail, SNMP trap) trip ped by pre-set thresholds. Connection is made v[...]

  • Page 9

    3402230800/A C - 9 RS232 link con figuration and conn ection RS485 link con figuration and conn ection For proper operation, the polarity of EIA RS485 2-wire and 4-wire lines must be set at only one point and the lines terminated at the end. Polar ity Normally, the ma ster of the network s ets the polarity of the line. The rec eiver inputs have a t[...]

  • Page 10

    10 - 3402230800 /AC 2 wires con nect ion Card settings of an interme diate cabin et Ot hers set ting s SA1 SA2 SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5 L + 43 2 1 L - 5V Rp Ra Rp 0V Ra 0V Ra 0V L- L- L+ L+ L- L- L+ L+ 3 7 24 13 24 13 polarity connection if end of the line polarity transmit/receive data transmit/receive data transmit/[...]

  • Page 11

    3402230800/A C - 11 4 wires con nect ion Card settings of an interme diate cabin et Ot hers set ting s SA1 SA2 5 R- 43 2 1 R + T - T + SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5V Rp Rp 0V Ra Ra T- R - T+ R+ R- R- R+ R+ 2 1 2 1 5V Rp Ra Rp 0V R- T - R+ T+ T- T- T+ T+ 4 3 4 3 master transmitt slav e receiver sla ve receiver termination t[...]

  • Page 12

    12 - 3402230800 /AC Configuration of the JBUS/MO DBUS commun ication p aram eters ◗ Use the cord supplied wit h the card ◗ Connect the card to a computer ◗ Use a terminal emulator such as HyperTerm inal TM with these settings "Echo typed characters locally" option: disabled ◗ Check t hat UPS power is on. ◗ Type MGEUPS (or mgeu p[...]

  • Page 13

    3402230800/A C - 13 ◗ Press the 2 key (Modifiy Jbus settings) ◗ Pr ess «R etur n» k ey to modi fy the Jbu s set tings * Hex for ma t. ◗ Press t he 0 key (Exit). ◗ Press t he 0 key (Exit). ◗ Run a brows er ◗ Enter in the address bar: http://IP address/ (e.g. http://172.16.1.82/) ◗ The hom e page is displayed ◗ Select the setting me[...]

  • Page 14

    14 - 3402230800 /AC ◗ Set the par ameters. ◗ Select the «Save» button to save the new parameters.[...]

  • Page 15

    3402230800/A C - 15 TECHNICAL CHARACT ERISTICS Physical characteristics Dimensions (W x D x H) 132 x 66 x 42 mm Weight 70 g RoHS 100% compatible Storage Storage tempera ture ra nge -10°C to 70°C Ambient c onditions Oper atin g t emp erat ure ran ge 0°C to 40° C Relative humidity 90% RH max. with out condensation Card performance Supply vol tage[...]

  • Page 16

    3402230800/AC 990-3402230800 AC When cor rectly installed and used in accordance with manufacturer instruc tions, the card complies with the following standards: ◗ ITE (Information Technology Equipment) safety: IEC/EN 60950-1 2005 ◗ EMC: EN 61000-6-2 (2005), EN 61000-6-3 (2006), IEC/EN 620 40-2 (2005) In comp liance with European directives: ?[...]