Antunes, AJ SE-4200/4400 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Antunes, AJ SE-4200/4400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Antunes, AJ SE-4200/4400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Antunes, AJ SE-4200/4400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Antunes, AJ SE-4200/4400 should contain:
- informations concerning technical data of Antunes, AJ SE-4200/4400
- name of the manufacturer and a year of construction of the Antunes, AJ SE-4200/4400 item
- rules of operation, control and maintenance of the Antunes, AJ SE-4200/4400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Antunes, AJ SE-4200/4400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Antunes, AJ SE-4200/4400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Antunes, AJ service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Antunes, AJ SE-4200/4400.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Antunes, AJ SE-4200/4400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    WA TER FIL TRA TION SY STEM Model SE-4200/4400 Owner ’ s Man ual P/N 1010852 Rev . C 04/06 MANUF ACTURING NUMBERS: 9700501 9700505 9700508 9700512[...]

  • Page 2

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 2 P/N 1010852 Rev . C 04/06 General Antunes Filtration T echnologies, a division of A.J. Antunes & Co., has partnered with companies from around the globe to produce the SE 4200/4400 water filtration system. The SE 4200/4400 removes bacteria and provides a substantial reduction of viruses that can enter [...]

  • Page 3

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 3 P/N 1010852 Rev . C 04/06 Purchased From: Date of Purchase: Model No.: Serial No.: Mfg. No.: Throughout this manual, you will find the following safety words and symbols that signify important safety issues with regards to operating or maintaining the equipment. W ARNING GENERAL W ARNING. Indicates informa[...]

  • Page 4

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 4 P/N 1010852 Rev . C 04/06 The following warnings and cautions appear throughout this manual and should be carefully observed. • T urn the unit off, disconnect the power source, and allow unit to cool down before performing any service or maintenance on the unit. • The equipment should be grounded accor[...]

  • Page 5

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 5 P/N 1010852 Rev . C 04/06 SPECIFICA TIONS Electrical Ratings CAUTION All electrical connections must be in accordance with local electrical codes and any other appli- cable codes. W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESUL T IN SERIOUS INJURY OR DEA TH.[...]

  • Page 6

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 6 P/N 1010852 Rev . C 04/06 Dimensions SPECIFICA TIONS (continued) A C B Control Box Drain Permeate (use water) Inlet[...]

  • Page 7

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 7 P/N 1010852 Rev . C 04/06 CAUTION W ater Pressure must not exceed 7 bar (100 psi). T o reduce water pressure, install a water pressure regulator and set water pressure to suit applica- tion. Note that the trans membrane pressure must be .5 - 3 bar (7.25 - 43.5 psi). CAUTION This equipment is to be installe[...]

  • Page 8

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 8 P/N 1010852 Rev . C 04/06 2” minimum 2” minimum Floor Drain Secure End Drain Line from System Drain Line from System Secure End Drain Standpipe INST ALLA TION (continued) Locating and Mounting the system Consider these points before mounting the system: • Note the location of the water supply , drain[...]

  • Page 9

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 9 P/N 1010852 Rev . C 04/06 CAUTION Ingesting the protective solution may cause irrita- tion of the gastrointestinal tract, colic, diarrhea, or other similar symptoms INST ALLA TION (continued) SANITIZING THE SYSTEM AND LINES The plumbing must also be sanitized to eliminate pos- sible contamination that may [...]

  • Page 10

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 10 P/N 1010852 Rev . C 04/06 OPERA TION Filtration Process The filtration process includes a Filtration Cycle and a Backwash Cycle. During the Filtration Cycle, water enters the system inlet port and passes through the filter elements before exiting via the Permeate outlet. This system is designed so that no[...]

  • Page 11

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 1 1 P/N 1010852 Rev . C 04/06 OPERA TION (continued) Programming 1. Once the system is connected to a power source, the unit displays the following messages in the table below in order: Message Description ANTUNES FILTRATION Rev. 00.00.00 Shows the software and hardware revision informa- tion. ver- BASIC ON:[...]

  • Page 12

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 12 P/N 1010852 Rev . C 04/06 OPERA TION (continued) SET QUICKFLUSH MODE NOTE: The Quick Flush function allows the sys- tem to be used for water systems containing a high quantity of air . Air does not pass through the filtration membranes. Performing a quick flush at pre-set times allows the accumulated air [...]

  • Page 13

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 13 P/N 1010852 Rev . C 04/06 OPERA TION (continued) 7. The system displays the FLUSH BY PRESS DIFF display . If the filtration system came with pressure transducers installed, this feature is available. If no transducers are installed, this feature is ignored. The default value is on . This should be appropr[...]

  • Page 14

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 14 P/N 1010852 Rev . C 04/06 OPERA TION (continued) 5. The system displays the SET ENABLE PASSWORD display . The default setting is off . If you do not want to use a password, press the Enter but- ton. The system will then display the SELECT LANGUAGE display . The default setting is English (other languages [...]

  • Page 15

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 15 P/N 1010852 Rev . C 04/06 OPERA TION (continued) Operating the Unit After all of the menus have been programed, the sys- tem can be activated. 1. T o start the filtration operation, press the RUN button. The system will perform a BORE AIR RELEASE function and return to FIL TER MODE. 2. T o stop any functi[...]

  • Page 16

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 16 P/N 1010852 Rev . C 04/06 MAINTENANCE The SE-4200/4400 Filtration system is designed to require very little maintenance. T o ensure that the water is of the highest quality , occasionally some ser- vice is required. Checking the Controller Program The program features and setting should be checked occasio[...]

  • Page 17

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 17 P/N 1010852 Rev . C 04/06 TROUBLESHOOTING Problem Possible Cause Corrective Action Unit does not have power . The power cord is not correctly plugged in. Plug power cord in correctly . The Control Display is blank. The power cord is not correctly plugged in. Plug power cord in correctly . Control Board is[...]

  • Page 18

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 18 P/N 1010852 Rev . C 04/06 Problem Possible Cause Corrective Action W ater leaks from Permeate Port. Permeate Port not tight. T ighten with strap wrench if necessary . O-rings not lubricated. Lubricate O-rings with food-grade lubricant. O-rings split, cut, or twisted. Replace O-rings. W ater leaks from sys[...]

  • Page 19

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 19 P/N 1010852 Rev . C 04/06 REPLACEMENT P ARTS - SE-4200/4400 See Inset A 1 2 5 8 9 10 1 1 15 12 13 14 16 17 18 20 22 23 25 26 28 29 30 32 31 33 34 35 37 36 38 39 40 41 42 43 45 Inset A 47 65 21 47a 47 48 22a[...]

  • Page 20

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 20 P/N 1010852 Rev . C 04/06 REPLACEMENT P ARTS - SE-4200/4400 (continued) Item Part Description Qty . No. Item Part Description Qty . No. 1 1001073 Label Control Panel 1 2 5550100 Enclosure Control-upper 1 5 7000434 SE Series 3 Board Controller 1 Replacement Kit 6* 304P1 13 Screw , FL THD #4-40 x 1 15/16”[...]

  • Page 21

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 21 P/N 1010852 Rev . C 04/06 WIRING DIAGRAM[...]

  • Page 22

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 22 P/N 1010852 Rev . C 04/06 NOTES[...]

  • Page 23

    SE-4200/4400 W A TER FIL TRA TION SYSTEM 23 P/N 1010852 Rev . C 04/06 NOTES[...]

  • Page 24

    LIMITED W ARRANTY Equipment manufactured by Antunes Filtration T echnologies, Division of A.J. Antunes & Co. has been constructed of the finest materials available and manufactured to high quality standards. These units are warranted to be free from mechanical and electrical defects for a period of one year from date of purchase or 18 months fr[...]