Amcor System QT 120 manual

1
2
3
4
5
6
7
8
9
10
11

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Amcor System QT 120, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Amcor System QT 120 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Amcor System QT 120. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Amcor System QT 120 should contain:
- informations concerning technical data of Amcor System QT 120
- name of the manufacturer and a year of construction of the Amcor System QT 120 item
- rules of operation, control and maintenance of the Amcor System QT 120 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Amcor System QT 120 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Amcor System QT 120, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Amcor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Amcor System QT 120.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Amcor System QT 120 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DEHUMIDIFIER QT 120 GB Instruction manual[...]

  • Page 2

    2 CONTE NTS Thank you 3 Safety Instructions 3 How it works 5 Placement 6 Operation 7 Emptying the water tank 8 Cleaning 9 Long term storage 9 T rouble shooting 10 T echnical data 10[...]

  • Page 3

    3 TH AN K Y OU SAFETY INSTRUCTIONS GB • Remove all packaging materials from the unit, keep it away from babies and small children to avoid the danger of suffocation. • Before inserting the plug make sure that the voltage is within the range indicated on the rating label on the unit. • The dehumidifier is intended exclusively for the use for w[...]

  • Page 4

    4 GB Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the power cable wires are frayed or cut When small children may be left unattended If an extension cord is needed to reach an outlet Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals W[...]

  • Page 5

    5 GB HOW IT WORKS C ondenser (W armed coil) E vaporater (Cold refrigerated coil) C ompressor Fa n Motor Micro switch W ater tank Dry warmer air Moist air Y our Amcor dehumidifier draws air through two filters onto a refrigerated cold coil. As the air in the room passes over the cold surface, moisture condenses and collects into a removable water ta[...]

  • Page 6

    6 GB PLACEMENT Y our AMCOR dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture travels throughout your home, in the same way that cooking smells spread to every room in the house. F or this reason, the dehumidifier should be positioned in a central and clear locatio[...]

  • Page 7

    7 GB CONTROL PANEL AND OPERA TION 1 2 3 4 ON and humidity level control [2] T urn the humidity control knob to the OFF position before connecting to the mains. Set the humidity controller to the required humidity level or fully clockwise to the maximum position for continuous working. By rotating the knob clockwise the unit will switch off at a low[...]

  • Page 8

    8 When the water tank is full, the unit will switch off automatically and the indicator [4] will illuminate. At this time, please empty the water tank as follows: • Slowly slide out the tank squarely using the recess at the bottom of the water tank as shown. • Holding the handle inside the container , pull it slightly up and then pull out gentl[...]

  • Page 9

    9 Always unplug the unit from the mains before carrying out any maintenance or cleaning the unit. Cleaning the body Only use a soft cloth to wipe the unit clean. Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other harmful cleansing solutions. These could all possibly damage the cabinet. Cleaning the air filter This[...]

  • Page 10

    10 GB TROUBLE SHOOTING TECHNICAL DA T A Model QT 120 Power supply 220 - 240 V / 50 Hz Power consumption (at 27 °C, 90% RH) W 195 Moisture removal (at 32 °C, 90% RH) L/24h 12 Refrigerant R-134A Refrigerant load g 180 W orking temperature °C 5 - 35 Dimensions (W x D x H) cm 33,7 x 28,6 x 53,5 Nett weight kg 13 Due to our continuous R+D program, sp[...]

  • Page 11

    QT 120 China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com Hong Kong Amcor Ltd [...]