Amcor SD12 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Amcor SD12, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Amcor SD12 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Amcor SD12. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Amcor SD12 should contain:
- informations concerning technical data of Amcor SD12
- name of the manufacturer and a year of construction of the Amcor SD12 item
- rules of operation, control and maintenance of the Amcor SD12 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Amcor SD12 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Amcor SD12, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Amcor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Amcor SD12.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Amcor SD12 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DEHUMIDIFIER SD12 GB Instruction manual[...]

  • Page 2

    2 CONTENT S GB Thank you 3 Safety Instructions 3 How it works 5 Placement 5 W all mounting 6 Operation 7 Drainage 8 Cleaning 9 Long term storage 9 T rouble shooting 10 T echnical data 10 Parts 1 1[...]

  • Page 3

    3 TH AN K Y OU SAFETY INSTRUCTIONS • Remove all packaging materials from the unit, keep it away from babies and small children to avoid the danger of suffocation. • Before inserting the plug make sure that the voltage is within the range indicated on the rating label on the unit. • The dehumidifier is intended exclusively for the use for whic[...]

  • Page 4

    4 Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the power cable wires are frayed or cut When small children may be left unattended If an extension cord is needed to reach an outlet Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals Wher[...]

  • Page 5

    5 Y our Amcor dehumidifier draws air through a washable filter onto a refrigerated cold coil. As the air passes over the cold surface, moisture condenses and collects into a removable water tank. The drier air , slightly warmer through heating by the condenser , is then expelled through the adjustable directional grill at the top of the unit into t[...]

  • Page 6

    6 Y our Amcor dehumidifier can stand on its 4 castors or can be hung on a wall. F or that purpose the following components are included: - 2 brackets with 4 screws and plugs to fix on the wall; - 2 hangers with 4 screws for the side of the unit; - 2 plastic suction spacers to help hanging the unit vertically . Slide the hangers through the slots in[...]

  • Page 7

    7 Starting and humidity control (humidistat) • Firstly , turn the control knob [2] to the position OFF. • Plug the power cord in a working mains socket. • T urn the control knob [2] clockwise to MAX for continuous operation, the operation indicator [3] will illuminate. After 24 hours, select the humidity level to be maintained by rotating the[...]

  • Page 8

    8 The extracted water can be collected in the water container or drained continuously through a flexible hose (not supplied). Use of the water container When the drain outlet is blocked by the stopper , the extracted water will run into the water container . When the container is full, the compressor and the fan stop operating and the container ful[...]

  • Page 9

    9 WARNING! First of all switch off the unit and pull the plug out of the wall socket. Housing Clean the housing with a soft, damp cloth and dry when clean. Never use chemically treated cloths, alcohol or any other product containing solvents as this may cause damage to the housing. Air filter This dehumidifier is equipped with a washable anti-dust [...]

  • Page 10

    10 Model SD12 Power supply 220-240 V/ 50 Hz Power consumption (at 32 °C, RH 90%) W 235 Current A 1.3 Moisture removal (at 32 °C, RH 90%) L/24h 12 Refrigerant R-134A Refrigerant load g 170 W ater container capacity L 4 Operating temperature range °C 5 - 35 Dimensions (width x depth x height) mm 420 x 220 x 540 Net weight kg 15 Subject to modifi [...]

  • Page 11

    11 1 10 2 9 3 8 4 7 5 6[...]

  • Page 12

    SD12 China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com Hong Kong Amcor Ltd Su[...]