Agilent Technologies AN 372-1 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Agilent Technologies AN 372-1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Agilent Technologies AN 372-1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Agilent Technologies AN 372-1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Agilent Technologies AN 372-1 should contain:
- informations concerning technical data of Agilent Technologies AN 372-1
- name of the manufacturer and a year of construction of the Agilent Technologies AN 372-1 item
- rules of operation, control and maintenance of the Agilent Technologies AN 372-1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Agilent Technologies AN 372-1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Agilent Technologies AN 372-1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Agilent Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Agilent Technologies AN 372-1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Agilent Technologies AN 372-1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Agilent AN 372-1 Power Supply T esting Application Note An electronic load offers a broad range of operating modes, providing versatile loading configurations needed for characterizing and verifying DC power supply design specifications.[...]

  • Page 2

    2 As regulated-pow er supply technology ev olves, testing methods for design verification and product function require more sophisticated electronic equip- ment. The different po wer suppl y architectures and output combinations also dictat e the need for versatile test instruments that can accommodat e a broad range of specifications. As a result,[...]

  • Page 3

    3 P ow er supplies are used in a wide variety of prod- ucts and test systems. As a result, t he tests per- formed to deter mine operating specifications can differ from manufacturer to manufacturer , or from end user to end user . For instance, t he tests per- formed in an R&D environment are primaril y for po wer supply design v erification. T[...]

  • Page 4

    4 Load T ransient Recovery Time A constant voltage DC pow er supply is designed with a feedback loop which continuously acts to maintain t he output voltage at a steady-st ate level. The feedback loop has a finite bandwidth, which limits the ability of t he po wer supply to respond to a change in the load cur rent. If the time delay between the po [...]

  • Page 5

    5 F or a step change in load cur rent, a marginally stable CV pow er supply will hav e a ringing voltage output. This defeats the purpose of the po wer sup- ply’s regulation circuitry and can be damaging to voltage-sensitive loads. An exam ple of a voltage- sensitive load is the logic circuitry in a computer . In this case, a computer manufacture[...]

  • Page 6

    6 Load Effect (Load Regulation) Load Effect or Load Regulation is a static per form- ance measurement which defines t he ability of a po wer supply under test to remain within specif ied output limits for a predetermined load change (see Figure 3). In a CV pow er supply , the inf luenced quantity of interest is the st eady-st ate output cur- rent. [...]

  • Page 7

    7 Current Limit Characterization Cur rent limit measurements demonstrat e the deg ree t o which a constant voltage pow er supply limits its maximum output current to a preset value. This preset value can be fixed or variable throughout a specified range. There are basically three types of current limiting design implementations: 1. Conventional cur[...]

  • Page 8

    8 P ARD (Periodic and Random Deviation) P ARD (f ormerly known as ripple and noise) is the periodic and random deviation of the DC output voltage from its a verage value, o ver a specified bandwidth, and wit h all other parameters con- stant. It is represent ative of all undesirable A C and noise components that remain in the DC output voltage aft [...]

  • Page 9

    9 T est Overview/Procedures T o make P ARD measurements, t he electronic load used should operate in CR mode for constant volt- age and constant cur rent po wer supplies. The load should also hav e lo wer P ARD than the pow er sup- ply being tested. This is especially important when measuring the P ARD of linear po wer supplies, since t hey typical[...]

  • Page 10

    10 Efficiency The eff iciency of a pow er supply is simply the ratio of its tot al output po wer to its tot al input po wer . T o obt ain the tr ue input po wer (rms voltage x in-phase rms cur rent) of a typical A C-to-DC converting po wer supply , commerciall y available wattmeters or A C sources can be used to measure the necessar y paramet ers. [...]

  • Page 11

    11 T o fully characterize the st ar t-up sequence of the po wer supply under test, measurements must be made of the output voltage response to t he instan- t aneous application of the AC in put (see Figure 1 1). A digital oscilloscope should be used so t hat stor- age of the output values can be accomplished f or the measured st ar t-up time period[...]

  • Page 12

    12 An observation of any DC po wer supply data sheet fr om a po wer suppl y manufacturer reveals a number of design specifications t hat must be verified and tested. These t ests oft en differ in technique and in the test equipment t hat is used to measure t he var- ious parameters. The common aspect of all of these tests is that a met hod of contr[...]

  • Page 13

    13 The Agilent Electronic Load Family offers the po wer suppl y test er t he solution f or man y of the tests t hat must be performed. For bench or system applica- tions in large or small scale testing environments, Agilent Electronic Loads pro vide high quality and reliability with superior per formance, features, and documentation. This will make[...]

  • Page 14

    By internet, phone, or fax, get assist ance with all your test and measurement needs. Online Assistance www .agilent.com/find/assist Phone or Fax United States: (tel) 1 800 452 4844 Canada: (tel) 1 877 894 4414 (fax) (905) 282 6495 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin Ameri[...]