ADT Security Services Universal Zone Coder manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ADT Security Services Universal Zone Coder, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ADT Security Services Universal Zone Coder one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ADT Security Services Universal Zone Coder. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ADT Security Services Universal Zone Coder should contain:
- informations concerning technical data of ADT Security Services Universal Zone Coder
- name of the manufacturer and a year of construction of the ADT Security Services Universal Zone Coder item
- rules of operation, control and maintenance of the ADT Security Services Universal Zone Coder item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ADT Security Services Universal Zone Coder alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ADT Security Services Universal Zone Coder, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ADT Security Services service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ADT Security Services Universal Zone Coder.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ADT Security Services Universal Zone Coder item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    D THE ADT-UZC-256 U NIVERSAL Z ONE C ODER for the Unimode ® 2020/1010, Unimode ® II and Unimode ® 4-16 Fire Alarm Control Panels Document 51349 4/25/00 Rev: A15216:D ECN 99-402 One Town Center Road Boca Raton, FL 33431 Phone: (561) 988-3600 FAX: (561) 988-3675 Security Services Inc.[...]

  • Page 2

    Precau-Lg.p65 01/18/2000 An automatic fire alarm system –typically made up of smoke detectors, heat detectors, manual pull stations, audible warn- ing devices, and a fire alarm control with remote notification capability–can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or[...]

  • Page 3

    Precau-Lg.p65 01/18/2000 WARNING - Several different sources of power can be con- nected to the fire alarm control panel. Disconnect all sources of power before servicing. Control unit and associated equip- ment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is energized. Do not attempt to insta[...]

  • Page 4

    4 51349:D 4/25/00 Contents Section One: ADT-UZC-256 Universal Zone Coder ......................................................... 5 Section T wo: Board Description ......................................................................................... 7 Section Thr ee: Installing the ADT-UZC-256 ..................................................[...]

  • Page 5

    5 51349:D 4/25/00 Section One: ADT-UZC-256 Universal Zone Coder General The ADT-UZC-256 Universal Zone Coder provides separate codes for up to 256 initiating zones. Each code requires a different initiating circuit. Only one Notification Appliance Circuit is required, but coded output from the ADT-UZC-256 can be fed to many output circuits. Coded O[...]

  • Page 6

    6 51349:D 4/25/00 Mounting The ADT-UZC-256 plugs into the ICA-4L in Unimode 2020/1010 systems, or mounts behind modules in the Unimode 4-16 and Unimode II. Additional Reference The ADT-UZC-256 Zone Coder can be used with the Unimode 4-16, the Unimode II, and the Unimode 2020/1010 Fire Alarm Control Panels. For more information on these systems, ref[...]

  • Page 7

    7 51349:D 4/25/00 TROUBLE LED (Yellow) Lights when one or more trouble conditions are detected. ALARM TEST (Red) Follows the main coded output. SLC ON-LINE LED (Green) Blinks during communication with the master FACP. 9V POWER CONNECTOR for powering the ADT-UZC-256 during remote programming. POWER OUT (Unimode II and Unimode 4-16 only) to next devi[...]

  • Page 8

    8 51349:D 4/25/00 Figure 3-1: Mounting the ADT-UZC-256 to a CHS-4 Section Three: Installing the ADT-UZC-256 Unimode II Installation Mechanical Installation The ADT-UZC-256 mounts beneath the third and fourth modules, to the right of the CPU. The ADT-UZC-256 fastens to the base of the CHS-4 chassis using the four hex standoffs (provided), which are [...]

  • Page 9

    9 51349:D 4/25/00 Unimode 4-16 Installation Mechanical Installation In a Unimode 4-16, the ADT-UZC-256 mounts beneath the third (right most) module. The ADT-UZC-256 fastens to the back of the box using three hex standoffs (one aluminum and two nylon provided), which are screwed into the three female PEM nuts as shown. The ADT-UZC-256 is then attach[...]

  • Page 10

    10 51349:D 4/25/00 Unimode 2020/1010 Installation Mechanical Installation In a Unimode 2020/1010, the ADT-UZC-256 plugs into a slot on the ICA-4L chassis. If the Unimode 2020/1010 is in an A-size cabinet (only one ICA-4L), the ADT-UZC-256 mounts beneath the CPU or the SIB. If a second or third ICA-4L chassis is available, the ADT-UZC-256 should be [...]

  • Page 11

    11 51349:D 4/25/00 Section Four: Power/NAC Configurations These two Notification Appliance Circuits share 3.0 amps of coded power. NOTE: Cable from MPS to ADT-UZC-256: P/N 71093; all others: P/N 71091. These two Notification Appliance Circuits share 3.0 amps of coded power. These four Notification Appliance Circuits share 3.0 amps of coded power. T[...]

  • Page 12

    12 51349:D 4/25/00 These two Notification Appliance Circuits share 3.0 amps of coded power. These two Notification Appliance Circuits share 3.0 amps of coded power. These eight Notification Appliance Circuits share 3.0 amps of coded power. These two Notification Appliance Circuits share 3.0 amps of coded power. These four Notification Appliance Cir[...]

  • Page 13

    13 51349:D 4/25/00 Section Five: Unimode 2020/1010 / ADT-UZC-256 Configuration MPS-24A Bell Power BATTERY BATTERY 3 AMP MAX. Universal Zone Coder ADT-UZC-256 XPM XPC-8 XPP-1 ARM-4 SLC EIA-485 ADT-LCD-80 CPU-2020 ADT-SIB-NET CRT EIA-232 CCM-1 LIB-200A UZC-2020.CDR[...]

  • Page 14

    14 51349:D 4/25/00 Section Six: ADT-UZC-256 Connections to M300CADT Modules System Sensor A2143-00 (Canada: N-ELR) End-of-Line Resistor, 47K, .5 watts, supervised and power-limited 24VDC Notification Appliance (See Device Compatibility Document 51352 for compatible devices) M300CADT SLC OUT The following illustration shows connections to an M300CAD[...]

  • Page 15

    15 51349:D 4/25/00 Appendix A: Plug/Terminal Schematic Code Relay 3 Code Relay 2 Code Relay 1 Coded Outputs 32 1 Coded Output 3 Power Input 3 Coded Output 2 Power Input 2 Coded Output 1 Power Input 1[...]