A&D UT-302PBT manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of A&D UT-302PBT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A&D UT-302PBT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of A&D UT-302PBT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of A&D UT-302PBT should contain:
- informations concerning technical data of A&D UT-302PBT
- name of the manufacturer and a year of construction of the A&D UT-302PBT item
- rules of operation, control and maintenance of the A&D UT-302PBT item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A&D UT-302PBT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A&D UT-302PBT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A&D service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A&D UT-302PBT.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the A&D UT-302PBT item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PBT DIGIT AL BL UETOO TH THEROMETER[...]

  • Page 2

    Inde x 1 2 3 3 4 5 6 7 10 11 14 14 15 15 16 18 Introduction Important Information Befor e Us e Produc t I dentification Description of LC D Display Battery Installation Changing Modes (°C/°F S witchable) T ips fo r M easuring Huma nT emperatur e M easuring Body Te m peratur e in th e Ear Memory F unction Car e an d Maintenanc e A pplied Standards[...]

  • Page 3

    1 Introduction Utilizing infrared technology , t his t hermomete r take s temperatures in seconds by m easuring h eat g enerated by th e ea r c anal or other objects .T his produc t c onforms to th e provisions of th e EC directiv e MDD(93/42/EEC).Its advantages include: 1. Wireles s communication : B luetoot h (clas s 2) 2. Intended use: Fo r home[...]

  • Page 4

    2 Important Information Before Us e W hen using t his product, p leas e be sure to f ollow all th e notes listed below .A ny action agains t t hes e notices ma y c aus e injur y or affect th e a ccuracy . 1. Do not disassemble, r epair , or remodel th e t hermomete r. 2. Be sure to c lean th e t hermomete r l ens each time a fte r usage. 3. Av oid [...]

  • Page 5

    Produc t Identification Probe Ti p P ower & M easur e Butto n LCD Display MEMO RY Recall Butto n Battery compartment lid Description of LC D Displa y Degrees of Te m peratur e Celsius Scale F ahrenheit Scale Sca n in Progres s Low battery Wa r ning Memory Symbol and Sets of Records Smiling face I ndicating temperatur e is lower t han 38° C ( 1[...]

  • Page 6

    Battery Installation Low battery w arning: W hen th e battery power becomes low , th e low battery symbol “” will a ppear on th e display .T he t hermomete r ca n still be used during t his time , bu t the batteries s hould be replaced as s oon as possible. If th e batteries ru n ou t completely ,“ Lo” will be displayed a long with th e lo [...]

  • Page 7

    5 Changing Mode s (°C/°F Switchable ) T his t hermomete r ca n display result in either degrees F ahrenheit(°F) or degrees Celsius(°C) . Changing °C / °F , p leas e mak e sur e th e device is in power on condition. Pres s th e Power/Sca n button, hold it , an d t hen pres s th e Memor y butto n to t oggle between °C an d °F .[...]

  • Page 8

    6 T ips fo r Measuring Human T emperatur e B ear in mind t hat th e t hermomete r needs to have b een in th e room in w hic h th e measurement is take n fo r at leas t 30 minutes befor e use. •S om e p eople produc e di ff erent r eadings in t heir lef t and right ea r. In order to recor d temperatur e c hanges , a lway s m easur e a person’ s [...]

  • Page 9

    M easuring B ody T emperatur e in the Ear 2. Pres s th e Power butto n to switch th e t hermomete r on. F ollowing a successful self test , th e device emit s tw o shor t b eeps . 3. Make sur e t hat th e sensor ti p an d also th e ea r c anal ar e clean. As th e ea r c anal is s lightly curved, yo u hav e to p ull th e ea r s lightly up an d backw[...]

  • Page 10

    5. Yo u may take ou t th e device to read th e m easurement result . 6. Th e backlight display will remain l ight fo r approximately 5 seconds eac h time the “Power & M easure” butto n is pressed, a fte r eac h reading is completed, an d each time the “Memory” butto n is presse d to recall a previous r eading. 7. Th e t hermomete r will[...]

  • Page 11

    M easuring B ody T emperatur e in the Ear 9 The R eadings : If th e temperatur e measurement is below 38°C , a “Smiling Face ” will be a ppear nex t to th e reading. If th e reading is 38° C or above, a “Frowning Face ” will be displayed.[...]

  • Page 12

    1. W hile in p ower on mode, pres s onc e briefly on th e “Memory” button, t hen pass it a gain to show th e last m easurement a ccompanied by “” symbol. 2. C ontinue to pres s the “Memory” butto n to view th e nex t previously stored measurement , so “” t hen al l th e wa y to “” . 10 M emory F unction Yo u can recall up to 10 [...]

  • Page 13

    11 Operating Th e B luetoot h F unction 1. Tu rn th e ea r t hermomete r to th e back s ide. 2. Tu rn on th e wireles s power (Fro m "o ff " to "on"), while th e t hermomete r s earches fo r other B luetoot h compatible devices, th e LE D (connection i ndicator ) will f lash. W hen th e device connects successfully to healt h mo[...]

  • Page 14

    12 Operating Th e B luetoot h F unction Wha tY ou N eed : Th e host computer or terminal s ystem to run Serial Port Profile ( SPP) -A personal computer wit h O perating s ystem : W indows 95 or later -A Smart P hone with A ndroid s ystem - Others: PDA, etc. Pleas e refer to th e instruction manual of y our personal computer fo r how to install Seri[...]

  • Page 15

    13 Operating Th e B luetoot h F unction Communications Interface: To connec t to a ne w device (new master ) the must be ou t of r ange fro m th e previous master or unpaired fro m t hat master . UT-302PBT Using Bluetooth communications terms, the UT -302PBT is a slave device. T o connect the UT -302PBT to a master device you must initiate the conn[...]

  • Page 16

    14 Care an d Maintenance • Clean th e probe an d ti p with an alcohol swab before an d a fte r eac h measurement . Probe an d T ip: • Us e a soft, dr y c lot h to clean t hermomete r body . Neve r us e abrasiv e cleaning a gents, t hinner s or benzene fo r c leaning. Do no t s cratc h th e surface of th e probe l ens or th e display . Do no t e[...]

  • Page 17

    • 34°C~43° C ( 93.2°F~109.4°F) • 35.5°C~42° C ( 95.9°F~107.6°F) : outside th e r ange: • 16 C~35 C ( 60. 8F ~9 5F ) wit h r elativ e humidit y up to 85 % ( non c ondensing) • -2 5C ~+5 5C (-1 3F ~+131 F) wit h r elativ e humidit y up to 85 % ( non c ondensing) • 0.1 C or F • 2 x 1.5 V AAA alkaline batteries • approx . 70 g ( w[...]

  • Page 18

    16 FC C Statemen t T his equipment ha s been tested an d f ound to comply wit h th e limits fo r a C las s B d igital device , pursuant to Part 15 of th e FC C R ules . T hes e limits ar e designed to provide reasonable protection a gains t harmful interferenc e in a residential installation. T his equipment g enerates , uses , an d can radiat e ra[...]

  • Page 19

    17 FC C Statemen t 6. T his devic e complies wit h Par t 15 of th e FC C R ules . O peration is s ubjec t to th e f ollowing tw o conditions : (1 ) t his devic e may not c aus e harmful interference, and (2) t his devic e mus t a ccept an y interferenc e received, including interferenc e t hat ma y c aus e undesired o peration. 7. T his devic e com[...]

  • Page 20

    18 EMC Ta ble s Guidanc e an d manufacturer's d eclaration-electromagneti c emission The intended fo r us e in th e e lectromagnetic environment s pecified below .T he customer or th e user of the should a ssure t hat it is used in such an environment . Thermometer Thermometer Emissions t est Complianc e Electromagneti c environmen t guidanc e[...]

  • Page 21

    19 EMC Ta ble s Guidanc e an d manufacturer's d eclaration-electromagneti c i mmunit y The is intended fo r us e in th e electromagnetic environment specified below. T he customer or th e user of the should a ssure t hat it is used in such an environment . Thermometer Thermometer I mmunit y test IE C 6 0601 t est l evel Complianc e l evel Elec[...]

  • Page 22

    20 EMC Ta ble s Recommende d separation distances between portable an d m obile RF communications e quipmen t an d the Thermometer The monitor is intended fo r us e in an e lectromagnetic environment in whic h r adiated RF disturbances ar e c ontrolled. Th e customer or th e user of th e ca n h elp prevent e lectromagnetic interferenc e by m aintai[...]

  • Page 23

    This device includes RF transmitter (with wireless communication) 21[...]

  • Page 24

    A&D Company, Limited 1-243 As ahi , K itamoto -s hi , S aitama 364-8585 JAPA N Telephone: [81](48)593-1111 Fax: [81](48)593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon , Oxfordshire O X14 1DY United Kingdom Telephone: [44](1235)550420 Fax: [44](1235)550485 A&D ENGINEERING, INC. 1756 A utomation [...]