Nortel Networks 553-3001-358 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244

Ir para a página of

Bom manual de uso

As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto Nortel Networks 553-3001-358. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoNortel Networks 553-3001-358 vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.

O que é a instrução?

A palavra vem do latim "Instructio" ou instruir. Portanto, no manual Nortel Networks 553-3001-358 você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.

Infelizmente, pequenos usuários tomam o tempo para ler o manual Nortel Networks 553-3001-358, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.

Então, o que deve conter o manual perfeito?

Primeiro, o manual Nortel Networks 553-3001-358 deve conte:
- dados técnicos do dispositivo Nortel Networks 553-3001-358
- nome do fabricante e ano de fabricação do dispositivo Nortel Networks 553-3001-358
- instruções de utilização, regulação e manutenção do dispositivo Nortel Networks 553-3001-358
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes

Por que você não ler manuais?

Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque Nortel Networks 553-3001-358 não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos Nortel Networks 553-3001-358 e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço Nortel Networks na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas Nortel Networks 553-3001-358, como para a versão papel.

Por que ler manuais?

Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo Nortel Networks 553-3001-358, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.

Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual Nortel Networks 553-3001-358. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação

Índice do manual

  • Página 1

    553-3001-358/ 555-4001-135 Nor tel Commu nication Server 1000/ Nor tel Communica tion Server 2100/Meridian SL-100 Nor tel Integrated Conference Bridg e Ser vice Implementation Guide ICB Release 4 Standard 02.00 J uly 2006[...]

  • Página 2

    [...]

  • Página 3

    Test this out Nor tel Communication Ser v er 1000/ Nor tel Communication Ser v er 2100/Meridian SL-100 Nor tel Integrated Conference Bridge Ser vice Implementation Guide Publication n umber : 553-3 001-358/55 5-4001-135 Product release : ICB Release 4 Document release: Sta ndard 02.00 Date: July 2 006 Cop yright © 2006 Nort el Netw orks. All r igh[...]

  • Página 4

    [...]

  • Página 5

    Nortel Integrated Co nference Bridge Service Implementation Guide 5 Pub lication history J uly 2006 Standard 02.00 ICB Release 4. This document is up-issued to address CR Q01140878, Procedure 13, “Configure initial car d parameters using the CLI” on page 71 , the def ault pass word is blank. J uly 2004 Standard 01.00, ICB Release 4.[...]

  • Página 6

    6 Publication history 553-3001-358/555-4001-135 Standard 02 .00 July 2006[...]

  • Página 7

    Nortel Integrated Co nference Bridge Service Implementation Guide vii Contents About this document 13 Product description 17 Purpose 17 ICB descript ion 17 Conference adm inistration 17 System overview 19 ICB conferen ce feature summ ary 19 Hardware overview 21 ICB hardware design characteristics 23 External equipment 26 ICB operat ion 27 Join the [...]

  • Página 8

    viii Contents 553-3001-358/555-4001-135 Stan dard 02.00 July 2006 Installation a nd configuration 45 Purpose 45 Getting star ted 45 Unpack and inspect the equip ment 46 Take inventory 46 Verify IPE Slot(s ) 46 Determine the acce ss method 46 Installing the NTCW84JA I/O P ane l Fi lter Connector for a Large System 47 CS 1000 configura tion 47 Summar[...]

  • Página 9

    Contents ix Nortel Integrated Co nference Bridge Service Implementation Guide Users 117 Call-out Groups 123 Permanent Co nferences 130 Telephone user interface 135 Purpose 135 Overview 135 Active confer ence 135 Scheduling and recording f eatures 135 TUI operation during an acti ve conference 136 Chairperson fe atures 136 Features available t o all[...]

  • Página 10

    x Contents 553-3001-358/555-4001-135 Stan dard 02.00 July 2006 Backup 187 Restore 192 Backup and restor e process log 193 Reports 195 Purpose 195 Overview 195 BUI Report Viewer 196 Short Connectio n Report 197 BUI Short Connectio n Report 197 CLI Short Connect ion Report 197 Meetings Log Repo rt 198 BUI Meetings Log Repo rt 198 CLI Meetings Lo g Re[...]

  • Página 11

    Contents xi Nortel Integrated Co nference Bridge Service Implementation Guide Appendix B: Pr oduct integrity 233 Environmental specifications 233 Regulatory standar ds 234 Safety 234 Electro-magnetic compatibility (EMC) 235 FCC Compliance 236[...]

  • Página 12

    xii Contents 553-3001-358/555-4001-135 Stan dard 02.00 July 2006[...]

  • Página 13

    Nortel Integrated Co nference Bridge Service Implementation Guide 13 About this document Purpose and audience This document instructs system administrators and installers how to install, configure, oper ate , and ma intain the Nor tel Networks Integrated Conf erence Bridge as a par t of the ov erall Meridian system. In this guide, Meridian system r[...]

  • Página 14

    14 About this document 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • “Bro wser user interface” on pa ge 79 – descr ibes how to use the browser user interf ace (BUI), a web-based ser v er , f or conf erence administration and scheduling, as we ll as user administration and maintenance of the ICB. • “T elephone user interface” o[...]

  • Página 15

    About this document 15 Nortel Integrated Co nference Bridge Service Implementation Guide software release cycle . Fo r e xampl e, the second release of a document in the same software release cycle is 01.02. Referenc es in this document Nor tel Netw orks Communication Server 1000 If you are installing the ICB in a Comm unication Ser v er 1000, see [...]

  • Página 16

    16 About this document 553-3001-358/555-4001-135 Standard 02 .00 July 2006 End user documentation The f ollowing documents apply to all platf or ms: • Nortel Networks Integrated Conf erence Bridge Release 4 User Guide, P0989944 – shows end user ho w to schedule and manage a conf erence using either the T e lephone User Interf ace or the Browser[...]

  • Página 17

    17 Nortel Integrated Co nference Bridge Service Implementation Guide Pr oduct description Purpose This chapter describes t he functional and physical char acter istics of the Nor tel Networks Integrated Conf er ence Br idge Release 4. T e chnicians can install the Integrated Conf eren ce Bridge (ICB) ca rd in either a Meridian 1, Nor tel Networ ks [...]

  • Página 18

    18 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The ICB card provides announcements and tones that relate to specific e vents during conf erences. Thes e e vents include the f ollowing: • advising the chair person and conf erees of the status of the conf erence connection • indicating when a conf eree join s or lea ve[...]

  • Página 19

    Product description 19 Nortel Integrated Co nference Bridge Service Implementation Guide The ICB communicates with the system software b y emulating a digital line card (XDLC), which allows e x isting softw a re to control the operation of the ICB . Configure eac h ICB por t as an Automatic Call Distribution (A CD) M26 16 digital telephone set. Sys[...]

  • Página 20

    20 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • Issues a 10-minute w ar ning, bef or e the conf erence ter mination. Also issues a second warning, two minutes bef ore conf erence ter mination. • Suppor ts dial-in and v oice prompt s f or multiple languages including: N.A. English, Latin-Americ an Spanish, F rench, B[...]

  • Página 21

    Product description 21 Nortel Integrated Co nference Bridge Service Implementation Guide • Controls access to the conf erence in progress by monitoring the maximum number of scheduled attendees at each conf erence. • Manages time and date f or schedul ed conf erences and reser v es por ts f or each conf erence. • Provides recorded announcemen[...]

  • Página 22

    22 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 1 ICB system composition G100564 Communication Server 1000 Users or administrators Web browsers or Outlook GUI Users or administrators Web browsers or Outlook GUI CRT (for initial setup only) Intranet or Internet 1. Y ou install one or more Integrated Conf erence Br i[...]

  • Página 23

    Product description 23 Nortel Integrated Co nference Bridge Service Implementation Guide ICB hard ware design characteristics Each ICB card occupies one slot in a Media Gatew ay chassis slot (CS 1000) or an IPE shelf (Meridian 1/CS 1000/CS 2100/SL-100). ICB Release 4 is based on a ne w hardwar e platf or m. The IC B card has the f ollowing hardware[...]

  • Página 24

    24 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • provides self-tests of intern al hardware components and allo ws card monitoring and maintenance through the maintenance por t; provides enab le/disable capabiliti es similar to e xisting Mer idian cards • provides one RS-232 serial por t f or administration and mainte[...]

  • Página 25

    Product description 25 Nortel Integrated Co nference Bridge Service Implementation Guide ICB card description The ICB card has two PCMCIA soc k ets. PCMCIA hard driv e cards store the ICB v oice files, applic ation scripts, and MPU and DSP fir mw are. The ICB comes with the PCMCIA hard drive . The bottom sock et houses the PCMCIA hard drive ca rd t[...]

  • Página 26

    26 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 result during power up or card insert ion into an operating system. This LED indicates the f ollowing: • The LED is lit when the ICB card is disabled. • The LED is off when the ICB ca rd is enabled and ready f or use. • The LED b links three times, runs software from t[...]

  • Página 27

    Product description 27 Nortel Integrated Co nference Bridge Service Implementation Guide Ethernet application ICB Ether net use has the f ollowing characteristics: • The ICB Ether net connection is s eparated from the e xter nal LAN traffic by a fire wall. • The Ether net Adapter connection f o r ICB is NT5D52AA f or the IPE module application.[...]

  • Página 28

    28 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The ICB uses A CD features to route e xter nal incoming tr unk and local line conf erees to thei r appropr iate conf erences. The A CD f eatures provide queuing, chairperson featur es , and ev ent r epor ting f or each conf erence. The A CD features used b y the ICB card pro[...]

  • Página 29

    Product description 29 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 3 Call routing with chairperson access Join the conference using the di rect meeting access method Assign a main DN and a chair pers on DN, f or each conference . The main DN is the number the conf erees dial to get into the conf erence and the chair per[...]

  • Página 30

    30 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 When se ver al conferences occur sim u ltaneously in the same ICB card, the conf eree dials the DN assigned to a specif ic conference . The ICB card identifies the dial ed DN and routes the conf eree to the appropriate conf erence represented by that s pecific DN. The system[...]

  • Página 31

    Product description 31 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 4 Single DN access meth od (one ICB card) The DNs on the left in Figure 4 ca n be Phantom DNs or CDNs, instead of A CD DNs. The DNs mu st be DID numbers . In a dual-card system, eac h card requires its ow n single-access DN. In a dual-card set, conf eren[...]

  • Página 32

    32 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 5 Single DN access method (tw o ICB cards) Note: All DNs on the left side of t he figure must be DID numbers . G100080 Single-access DN for simple meetings Dual meeting chairperson DN Voice link DN Dual callers transfer DN Hidden from end users TUI services dial-in (s[...]

  • Página 33

    Product description 33 Nortel Integrated Co nference Bridge Service Implementation Guide Single DN access is mutually e xclus iv e from the direct meeting access method in a IC B card or card pair . Conf igure the card for one access method; the system does not suppor t comb inations on the card or card pair . Callers to all meetings access t he IC[...]

  • Página 34

    34 Product description 553-3001-358/555-4001-135 Standard 02 .00 July 2006 When the conf erence time expires , the ICB card issues the final warning to the conferees . The ICB sends a release message to the Meridian system for all associated ICB por ts. These por ts become a v ailable f or the next planned conf er ence . If there is no other schedu[...]

  • Página 35

    35 Nortel Integrated Co nference Bridge Service Implementation Guide Engineering guidelines Purpose This chapter prov ides guidelines f or engi neering ICB Release 4. Engineering guidelines can var y depending on the system platf o rm. The chapter includes the f ollowing sections: • “System requirements” on page 35 – outlines the software a[...]

  • Página 36

    36 Engineering guidelines 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Meridian 1 and CS 10 00 software packa g es In addition to standard basic software, the f ollowing softw are packages are required: • A CD basic package (45) • A CD advanced f eatures (41) • Digital set (88) • End-to-end signaling (10) – require d if chair perso[...]

  • Página 37

    Engineering guidelines 37 Nortel Integrated Co nference Bridge Service Implementation Guide System capacity Ph ysical Capacity Each ICB card occupies one slot on the Gate wa y/IPE chassis shelf. The total number of ICB cards per system is limited b y these factors: • F or Mer idian 1 or CS 1000M: The number of IPE shelv es multiplied by eight. Op[...]

  • Página 38

    38 Engineering guidelines 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • Option 81, 81C • SL-1 systems with IPE upgrade (NT and XT) CS 1000 ICB Release 4 is compatib le with al l CS 1000 systems . CS 2100/Meridian SL-100 system compatibility ICB Release 4 is compatible with all CS 2100/Meridian SL-100 system configurations . A utomatic c[...]

  • Página 39

    Engineering guidelines 39 Nortel Integrated Co nference Bridge Service Implementation Guide • An ICB card configured to the maximum capacity of 32 por ts and 10 simultaneous conf erences requires 87 A C D DNs and 32 TNs/LENs as f ollows: — one A CD DN assigned to the ICB card — 32 TNs/LENs assigned to the 32 por ts (1 P DN and 1 SDN for each [...]

  • Página 40

    40 Engineering guidelines 553-3001-358/555-4001-135 Standard 02 .00 July 2006 LAN configuration ICB customers should sele ct one of the f ollowin g alter nativ es for B UI access: • users and administrators access t he ICB from the global inter net (the new capability of MICB Release 3) • users and administrators acce ss the ICB from the custom[...]

  • Página 41

    Engineering guidelines 41 Nortel Integrated Co nference Bridge Service Implementation Guide Hosts that need to be accessed fr om the W or ld Wide W eb must be placed in a special sub-network called the Green an d Red LAN. The firew all isolates the Green and Red LAN from the C-LAN. De vices that can be accessed from the W or ld Wide W eb are put in[...]

  • Página 42

    42 Engineering guidelines 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 7 LAN/intranet access onl y – C-LAN connection Figure 8 on page 43 shows an e xample of the E-LAN connection. G100278 ICB BUI ICB BUI ICB BUI ICB BUI ICB BUI IPE Module ICB 4 card (s) C-LAN W orld Wide We b E-LAN 10/100 Base-T or 100 Base-T 10/100 Base-T PBX E-LA[...]

  • Página 43

    Engineering guidelines 43 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 8 LAN/intranet access onl y – E-LAN connection Notes The f ollowing notes apply to LAN/intranet access only: • The ICB does not interact with the Meridian syst em through the E-LAN, so logically th ere is no requirement to put it there. In additio[...]

  • Página 44

    44 Engineering guidelines 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • When there are multiple ICBs (that is , more than th ree) and the BUI is used frequently , the BUI traffic can load the E-LAN, so it ma y be better to connect the cards to the C-LAN. • The ICB has a broadcast-stor m prot ection mechanism: it shuts off the LAN por t [...]

  • Página 45

    45 Nortel Integrated Co nference Bridge Service Implementation Guide Installation and configuration Purpose This chapter describes how to prepare the system f or installation, install the ICB into: • the IPE module f or Mer idian 1 • the Option 11 shelf • the Media Gatew a y for CS 1000 • the IPE module f or CS 2100/Mer idian SL-100 This ch[...]

  • Página 46

    46 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Unpac k and inspe ct the equipment Unpack and inspect t he equipment f or damage. F ollow the steps in Procedure 1 , bef ore performing the insta llation and configuration procedures in this chapter . Procedure 1 Prepare f or the installation 1 Remov e items from [...]

  • Página 47

    Installation and configuration 47 Nortel Integrated Co nference Bridge Service Implementation Guide single-number access m ode , configure only t he single-access DN. In both cases, the B UI provides inst ructions about wh at to do ne xt. Installing the NTCW84J A I/O P anel F ilter Connector for a Lar ge System F or Large Systems, the standard IPE [...]

  • Página 48

    48 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Assign A CD DNs The first step is to assign A CD queue. Note: The number of DNs defined f or each ICB card using direct meeting access depends on the number of conf erences and bridges specified on the card. A maximum of 10 conf erences can be configured requiring[...]

  • Página 49

    Installation and configuration 49 Nortel Integrated Co nference Bridge Service Implementation Guide Enter the CS 1000 definitions f or the Phantom TN in LD 10 as follo ws: 1 The specific TN and DN v ar y by site . Those v ar iab les are represented b y “x” in Figure 9 on page 49 . 2 CFXA is the Class of Ser vice (C LS) that enables Call F orwar[...]

  • Página 50

    50 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The number of vir tual A CD agents of the ACD queue is equal to the number of ICB por ts. F or example , if 12 por ts are e nabled, define 12 A CD agents. If the TN f or the ICB card is specified as 28 0 6, then TNs f or the 12 agents are specified as 28 0 6 0 thr[...]

  • Página 51

    Installation and configuration 51 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 10 LD 20 ICB configuration CHG[...]

  • Página 52

    52 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Configure DNs f or a dual-card conference When a dual-card conf erence is defin ed, two meetings are defined on two cards . First, the meeting is book ed on the primar y card allocating the maximum free por ts. Second, the meeting is book ed on the secondar y card[...]

  • Página 53

    Installation and configuration 53 Nortel Integrated Co nference Bridge Service Implementation Guide F or the secondar y card, conf igure the f ollowing DNs: • DN pairs (up to nine) – These pairs ser v e as chair person and conf eree DNs for single-card co nf erences (less than 32 por ts) on the secondar y card. Note: If single-number access is [...]

  • Página 54

    54 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 T ab le 9 shows a sample dial ing plan f or a 62-por t dual-card configuration. Note: Carriage retur n to the end and star t again. REQ NEW New control data block. TYPE NA CD Network ACD dat a bloc k. CUST xx Customer number . A CDN x xxx The main DN f or dual-car[...]

  • Página 55

    Installation and configuration 55 Nortel Integrated Co nference Bridge Service Implementation Guide Note: Because of the number and v a r iety of DNs progr ammed for the dual-card setup , Nor tel Networ ks recommends creating a dialing plan char t similar to T able 9 on page 54 . Ref er to this char t when configuring the pr imar y and secondar y c[...]

  • Página 56

    56 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 11 Single-car d conference, 10 conferences, 32 ports Configuration procedure Single-card installation enab les up to 10 conference s on one 32-por t ICB card. Each ICB card can us e one ICB A CD Group to handle all the access DNs required. T o configure an [...]

  • Página 57

    Installation and configuration 57 Nortel Integrated Co nference Bridge Service Implementation Guide 3 Define the ICB conf erence and chair person bridge DNs. Ref er to Figur e 16 on page 58 . This step provides the f ollowing: a Main DN for conference A C D groups to access the ICB agents on th e card. b Conf erence DNs and Chair person DNs . c TUI[...]

  • Página 58

    58 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 14 AC D S G R P e x a m p l e Figure 15 A CDLOGIN example 6 The A CD login ID must match the ICB physical por t connectio n to the CS 2100/Meridian SL-100. The A CD agents login must be in descending order , otherwise the ICB card cann ot login the agents. [...]

  • Página 59

    Installation and configuration 59 Nortel Integrated Co nference Bridge Service Implementation Guide • K ey 2: Secondar y DN • K ey 3: Not Ready (NRD ) • K ey 4: A CD N ot Ready (A CDNR) • K ey 5: F ast T ransf er (FXR) The f ollowing ex ample shows how to datafill the A CD agents using SER V ORD . The configuration requires up to 32 LENs an[...]

  • Página 60

    60 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Dual-card configuration The dual-card configuration enab les a single conference to occur on two cards and ha ve up to 62 par ti cipants depending on access type. In the dual-card configuratio n, one card is the primar y card, and the other is the secondar y card.[...]

  • Página 61

    Installation and configuration 61 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 20 Dual-card conf erence, 1 conference , 62 ports G100017 ICB Card Table DNROUTE ICB1 997-1400 Table OFRT 601 997-1400 Table DNROUTE ICB1 997-1601 997-1602 997-1603 997-1604 997-1605 997-1606 997-1607 997-1608 997-1609 ICB1 997-1701 997-1702 9[...]

  • Página 62

    62 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Service Orders Add an additional A CD grou p fo r the second card. Figure 21 A CDGRP example Add additional A CD subgroup inform ation for the second card. Figure 22 A CDSGRP example Add additional login IDs f or the second card agen t logins. These login IDs must[...]

  • Página 63

    Installation and configuration 63 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 24 DNROUTE e xample Use tab le A CDR TE to a llo w a dual-card conferen ce to o verflo w from ICB card 1 to ICB card 2 when there are no more av ailabl e por ts on card 1. Figure 25 A CDRTE e xample Use tab le OFR T to add the DN r outing for [...]

  • Página 64

    64 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 3 Configure a dual-card conf erence 1 Install the two car ds and their Eth er net adapters identical to single -card installation. See Procedur e 4 on page 66 . Note: There is no need f or the two cards to be ne xt to each other in the shelf or cabine t.[...]

  • Página 65

    Installation and configuration 65 Nortel Integrated Co nference Bridge Service Implementation Guide ICB installation and configuration pr ocedures Once the site is pr epared f or installation a nd the Mer idian system software is configur ed, use the steps in Ta b l e 1 1 to complete the ICB installation. Ta b l e 11 ICB installation summary Step D[...]

  • Página 66

    66 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 4 Install the Ethernet Adapter card 1 Remov e the cover plate from the I /O panel at the rear of the IPE mo dule. 2 Remov e the I/O panel retaining scr ews and lift the I/O pane l from th e module. 3 Set up the I/O panel f ilter connector f or the card s[...]

  • Página 67

    Installation and configuration 67 Nortel Integrated Co nference Bridge Service Implementation Guide Ref er to Figure 27 when connecting the Maintenance ter minal (that is, VT100) in the f ollowing procedures . Figure 27 T erminal connection through the Ethernet Adapter Procedure 5 Access the ICB directly 1 P osition the Mainte nance ter minal on a [...]

  • Página 68

    68 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 4 Plug the DB-25 ma le connector at the other end of t he terminal cable int o the RS-232 connector on the terminal. A nullmodem is not required. If a gender This procedure is no w complete changer is required, purchase one from a local elect ronics store. Procedu[...]

  • Página 69

    Installation and configuration 69 Nortel Integrated Co nference Bridge Service Implementation Guide In the procedures that f ollow , the connections are the same f or the Option 11C and the CS 1 000, the only diff erence is that the connectors are on the back of the Call Server and Media Gate wa y f or the CS 1000, whereas they are on the botto m o[...]

  • Página 70

    70 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 3 Plug the DB-25 ma le connector at the other end of t he terminal cable int o the DB-25 f emale connector of the cu stomer-supplied DB-25F/DB-25M nullmodem ad apter . 4 Plug the DB-25 male conn ector of the DB-25F/DB-25M n ullmodem adapter into the DB-25 f emale [...]

  • Página 71

    Installation and configuration 71 Nortel Integrated Co nference Bridge Service Implementation Guide Procedure 12 Set up CLI access from the maintenance terminal 1 Specify the VT -10 0 type ter minal interface character istics to make sure they are compatib le with the ICB RS-2 32 interf ace. 2 Set the interf ace parameters as f ollows: • T ransmi[...]

  • Página 72

    72 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 where XXX is in the range 0-255. Subn et mask in binary presentation of 32 bits has at least the first eight dig its “1” and the last digit is “0”. • Gatew ay address – Is in the XXX.XXX.XXX.XXX f o rmat, where ev er y tok en is in the range 0-255. 8 E[...]

  • Página 73

    Installation and configuration 73 Nortel Integrated Co nference Bridge Service Implementation Guide The Installation Wizard consists of f our steps, each of which appears on a separate windo w . F or a new in stallation, f ollow the Wizard step-b y-step . F or already installed syst ems, go directly to a specific window to modify one or more fields[...]

  • Página 74

    74 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 28 Installation Wizard: Step 1 – Basic Car d Setting s window T ab le 14 descr ibes the parameters , from top to bottom, of the Basic Card Settings window . Submit this window to sav e the parameters in the card and continue to the ne xt step. Submit this[...]

  • Página 75

    Installation and configuration 75 Nortel Integrated Co nference Bridge Service Implementation Guide Type Define the card ’s configuration type as follows: • Single card (stand-a lone). • Primary card in a dual- card pair. • Secondary card in a dual-car d pair. Note 1: Dual-card meeting config uration in Step 4 uses this information. If info[...]

  • Página 76

    76 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Step 2 – Access Numbers Use this step to define the access method, direct meeting or single-number , and the DNs a ccording to Meridian system configuration. Figure 29 show s the Access Numbers window . Figure 29 Installation Wizard: Step 2 – Access Number s w[...]

  • Página 77

    Installation and configuration 77 Nortel Integrated Co nference Bridge Service Implementation Guide T ab le 15 descr ibes the parameters , from top to bottom, of the Access Numbers window . Configure all the DNs in this win do w according to Meridian system configuration. Step 3 – Define First User This step appears only during a new in stallatio[...]

  • Página 78

    78 Installation and configuration 553-3001-358/555-4001-135 Standard 02 .00 July 2006 allow ed only on the pr imar y card; on the secondar y card this windo w appears as vie w only . Note: The secondar y ICB card must be installed and configured first. Dual-card meeting param eters and DNs are defined in the primar y ICB only . The primar y ICB s e[...]

  • Página 79

    79 Nortel Integrated Co nference Bridge Service Implementation Guide Br o wser user interface Purpose This chapter describes how to use t he browser user interf ace (BUI), a web-based application, f or conf erence scheduling, chair person operations , and system administration. The chapter contains t he f ollowing sections: • “Overview” on pa[...]

  • Página 80

    80 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 User types When logging in to the ICB BUI, y our l ogin ID connects you to the server as a distinct user type. The admini strator determines the user type for each user . T able 17 shows the user types and their functionality . Log into the BUI Figure 30 shows the first w[...]

  • Página 81

    Browser user interface 81 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 30 ICB home page lay out The only possibl e action from this window is to clic k on the LOGIN but t on . F ollow the steps in Procedure 15 to login. Procedure 15 Login to the BUI 1 Click on the LOGIN b u tton. The window in Figure 31 appe ars.[...]

  • Página 82

    82 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 31 Login dialog bo x (Internet Explorer) 2 Enter y our login ID in the “U ser name” fi eld. T o log into t he administrat or BUI, enter an administr ator ID . 3 Enter y our pass word in the “P asswor d” field. When logging in the first ti me, enter six zero[...]

  • Página 83

    Browser user interface 83 Nortel Integrated Co nference Bridge Service Implementation Guide This procedure is no w complete Depending on the login ID type, T able 18 sho ws the windows that open when entering the BUI. Login passw ord change F ollow the steps in Procedure 16 to change pass words after logging in. Procedure 16 Change your login pass [...]

  • Página 84

    84 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 33 Change pass wor d windo w 2 Enter the curr ent passw o rd f or authentication, t hen the new passw or d. Enter the new pass wor d a second time f o r confir mation. The passwor ds do not appear when entere d (a sterisks appear). 3 Click on the Submit button to a[...]

  • Página 85

    Browser user interface 85 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 34 BUI fix ed title frame Help window Clicking on the Help b utton on the title frame opens a separa te browser window in which it displa ys the Help window . This e nables users to continue with B UI operations wh ile the on-line help is open. The f [...]

  • Página 86

    86 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Scheduling BUI Figure 35 shows the na vigation between the Scheduling BUI windo ws. Figure 35 Scheduling B UI navigation flo w c har t ICB Home Page G100083 Edit Delete New Conf erence Set Conf erence Reset Cancel Show ports av ailability Is successful? scheduling OK OK Y[...]

  • Página 87

    Browser user interface 87 Nortel Integrated Co nference Bridge Service Implementation Guide Meetings List window Figure 36 shows the Meeting List windo w that appears directly after user login. This window displa ys a table of the user’ s meetings and provides access to scheduling oper ations. Figure 36 Meetings List window (super-user’ s displ[...]

  • Página 88

    88 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 • Copy icon – conf erence details are c opied from the e xisting conf erence. • Gavel icon – jump to the “Meeting Co ntrol” windo w for an activ e conf erence (the icon appears on ly f or activ e conf erences). The BUI can displa y past conf erences, up to the[...]

  • Página 89

    Browser user interface 89 Nortel Integrated Co nference Bridge Service Implementation Guide T o schedule a ne w conf erence, clic k on the New Conf erence button on the top left-hand cor ner of the window . A new window appears (see Figure 37 on page 90 ). Scheduling windo w Click on the Ne w Conference b utton, or click on t he edit icon (a pencil[...]

  • Página 90

    90 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 37 Scheduling windo w – Schedule a New Conference All fields hav e def aults, b u t users typically select the date and time , and number of par ticipants . The system pro vides de f aults f or the other parameters or generates t he v alues automatically . After [...]

  • Página 91

    Browser user interface 91 Nortel Integrated Co nference Bridge Service Implementation Guide Number of participants Enter the number of por t s to reserve fo r this conference, including the chairperson ports. The application makes sure that the total number of reserved ports for this ti me period does no t e xceed system capacity. The system perfor[...]

  • Página 92

    92 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 When the calendar icon is click ed (loc ated ne xt to the drop-down menu f or the date), the calendar window opens as depicted in Figure 38 . The meeting date can be selected b y cl icking the appropriate date on the calendar . Figure 38 Calendar icon When in edit mode, t[...]

  • Página 93

    Browser user interface 93 Nortel Integrated Co nference Bridge Service Implementation Guide Only the f ollowing fields can be edited dur ing an activ e conference: • number of par ticipants • duration • add por ts as needed (under the Options section) Free P or ts section Figure 39 shows the ho w the sc heduling window is e xpanded after clic[...]

  • Página 94

    94 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Options section Figure 41 shows ho w the scheduling window is e xpanded after clicking on the Options b utton. Figure 41 Scheduling windo w – Options section T ab le 21 descr ibes the fiel ds in the Options section. Closes (collapses) the window while still sh owing the[...]

  • Página 95

    Browser user interface 95 Nortel Integrated Co nference Bridge Service Implementation Guide Chairperso n Password Enter a password for cha irperson authentication. This field has t he same options as th e user password. Note: The default setting is determined by the Administrato r’s default conference setting. Recurrence secti on (Does not appear[...]

  • Página 96

    96 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Scheduling Confirmation Figure 42 on page 97 shows the windo w that appears after successfully scheduling a new , or modifying an existing, meeting. The system displa ys the window after it stores the conf erence in the database. The BUI displa ys the conf erence details [...]

  • Página 97

    Browser user interface 97 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 42 Scheduling Confirmation windo w In the case of a recurr ent meeting, a Conf eren ce Dates section appears at the bottom of this window . The Conference Dates section lists the dates in which the conf erence is scheduled, including the first date sp[...]

  • Página 98

    98 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Recurrent Meeting V e rify Result window Figure 44 shows the windo w that the system displays when the Ve r i f y button is clic ked when settin g up a recurr ent conf erence. Figure 44 Recurrent Conference V e rify Result window The window displa ys the success result fo[...]

  • Página 99

    Browser user interface 99 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 45 Meeting Control windo w – Active chairper son T ab le 22 descr ibes the options av aila b le in the Meeting Control window . When this window is reached from the meeting list, click on this b utton to retur n to the Meetings List window . Updates[...]

  • Página 100

    100 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Chairperson section Active c hairperso n If the chairperso n joins the conference by dialing in, this field shows the CLID of the call, if available. If not available, the window display s “the number is unavailabl e”. If the chairperso n joins the call by outdialing[...]

  • Página 101

    Browser user interface 101 Nortel Integrated Co nference Bridge Service Implementation Guide The system updates the window autom atically e ver y two min utes. Session Management The chair person can request a v o ti ng session or questions to be ans wered by the par ticipants on the call. See Figure 46 f or a depiction of the Session Management ar[...]

  • Página 102

    102 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 47 V oting Session Control P anel Once v oting is enabl ed, par ticipants can vo te using the DTMF commands. The chairperson enters the subject of the voting in the Subject bo x. For e xample, “Do we require a f ollow-up conf erence?” The subject area is free [...]

  • Página 103

    Browser user interface 103 Nortel Integrated Co nference Bridge Service Implementation Guide b utton or the b linking question mar k. The chos en par ticipant receiv es the v oice prompt “Please ask y our question af ter the tone”. The chair person can sor t the par ticipant list b y question mar k b y pressing the “?” on the t op left of t[...]

  • Página 104

    104 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 49 Meeting Control windo w – Chairperson not present The f ollowing f eatures are unav ailable in this mode: • Self mute/unmute • Stop/pla y music • V olume control • Dial out • Consult with par ticipant After the chair person joins the c onf erence th[...]

  • Página 105

    Browser user interface 105 Nortel Integrated Co nference Bridge Service Implementation Guide Release chairper son control The Meeting Control window contains a Release b utton to release chair person control. This b utton re leases both TUI and BUI control. When the Release b utton is press ed, the v oice prompt “you are a regular conf eree” is[...]

  • Página 106

    106 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 51 Administration BUI na vigation flowc har t ICB Dashboard Basic settings Access numbers Define first user Dual-card meetings Install Wizard CLI button CLI window G100266 (Administrator login) ICB Home Page LOGIN OK ICB Home Page Login dialog box Links Links Retu[...]

  • Página 107

    Browser user interface 107 Nortel Integrated Co nference Bridge Service Implementation Guide ICB Dashboard The ICB organizes the Dashboard as an internet por tal. The Dashboard groups links b y subject (see Figure 52 ). Figure 52 Administration BUI ICB Dashboar d window The title frame on top , wh ich is present f or all administration windows , co[...]

  • Página 108

    108 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The ICB Dashboard has th e f ollowing sections: • ICB Installation Wizard • Settings • Users • P er manent Conf erences • Upgrades • Call-out Groups • Repor ts • Back up Settings This subject groups se ver al parame ters and definitions. Links to sub-subj[...]

  • Página 109

    Browser user interface 109 Nortel Integrated Co nference Bridge Service Implementation Guide Ta b l e 23 General Settings window fields Field Description Administration E-mail Enter the E-mail addre ss to which the ICB sends administration materi al, including backup files. Billing option Select a billing option f or this card from the pull-down me[...]

  • Página 110

    110 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Default conference Figure 56 shows the windo w in whic h an administrator can set as the def ault conference settings . Figure 54 ICB Dashboard – Defaul t Conf erence Settings T ab le 26 descr ibes the options a vai lab le in the Default Conf erence Settings window . W[...]

  • Página 111

    Browser user interface 111 Nortel Integrated Co nference Bridge Service Implementation Guide V olume Level Figure 56 shows the windo w in whic h an administrator can customize the volume le vel settings. Figure 55 ICB Dashboard – V olu me Level Settings T ab le 26 descr ibes the options a vaila b le in the V olume Le v el Settings window . Indica[...]

  • Página 112

    112 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 E-mail template Figure 56 shows the windo w in whic h an administrator can customize the scheduling confir mation E-mail. Figure 56 ICB Dashboard – Confirma tion E-mail Settings Speak: Enter th e default setting for the speaking volume le vel of the conferee in an aud [...]

  • Página 113

    Browser user interface 113 Nortel Integrated Co nference Bridge Service Implementation Guide The window sho ws the lay out of the E-ma il. The customizable te xt fields are editab le. Additional par ameters to define appear at the bottom of the window . T ab le 26 descr ibes the options a vai lab le in the Confir mation E-mail Settings window . Ta [...]

  • Página 114

    114 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Customize greetings Figure 57 shows the windo w used to customize the f ollowing greetings: • Brandline greeting • P er-conference user’ s greeting Figure 57 ICB Dashboard – Gree ting Settings windo w The tab le in this window lists the av ailable languages . For[...]

  • Página 115

    Browser user interface 115 Nortel Integrated Co nference Bridge Service Implementation Guide Procedure 17 Replace the brandline greeting 1 Upload the .W A V file from y our computer to the ICB using y our computer’ s operating syst em. a Click on the Browse button. A Choose dialog box opens on you r computer. b Scroll through the dialog bo x to s[...]

  • Página 116

    116 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Company images upload Figure 58 shows the windo w that an administrator can use to customize the ICB home page image and the customer ’ s logo on the title frame. Images must be in GIF f or mat. Figure 58 ICB Dashboard – Com pan y Images window Title Frame Image “N[...]

  • Página 117

    Browser user interface 117 Nortel Integrated Co nference Bridge Service Implementation Guide 4 T o activate the image, click on the Submit butt on. The new image becomes the custome r logo and the system discards the previous image. Note: If the Reset b utto n is clic ked, instead of the Subm it b utton, the This procedure is no w complete system d[...]

  • Página 118

    118 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 59 ICB Dashboard – User List windo w The b uttons on top of the window ar e f or additional administrator actions; the sections that f ollow describe these actions. The window displa ys a list of users in the f or m of a tab le that the systems sor ts alphabetic[...]

  • Página 119

    Browser user interface 119 Nortel Integrated Co nference Bridge Service Implementation Guide Edit a user When an administrator clic ks on a name in the Us ers List window , the Edit User Details window opens (see Figure 60 on page 120 ). Use the Edit User Details window to modify the proper ties of an e xisting user . The window sho ws all the prop[...]

  • Página 120

    120 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 60 ICB Dashboard – User s > Ed it User Details window Add ne w user Click on the Ne w User b utton in the User Li st window to access the Ne w User window . Use the New Us er windo w to add new users (see Figure 61 on page 121 ). Submit changes to sav e new u[...]

  • Página 121

    Browser user interface 121 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 61 ICB Dashboard – User s > New User windo w Note: The pass word f or a new user is initially 000000 (that is, six zeros). Nor tel Networks recommends that the user change it dur ing the first login session. Searc h for a user When the Search f [...]

  • Página 122

    122 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Click on one of the Sear ch by: radio b uttons to specify the field to search.The f ollowing options are av ailable: • Name (the system treats the wh ole name as one string and makes no distinction between first and last name) •U s e r T y p e • User ID The system [...]

  • Página 123

    Browser user interface 123 Nortel Integrated Co nference Bridge Service Implementation Guide T ab le 28 descr ibes the inf or mat ion that this message displa ys. Click on the OK b utton to star t the impor t process . When the system completes the impor t, it updates the User Li st window to include impor ted users. At this point, the us er can be[...]

  • Página 124

    124 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 64 ICB Dashboard – Call-Ou t Gr oup List window The window displa ys a list of groups in the form of a table , sor ted by group nu mber . The table is read-only . Ta b l e 2 9 describes the inf or mation that appears in the table’ s columns. Click on the Ne w [...]

  • Página 125

    Browser user interface 125 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 65 ICB Dashboard – Call-Out Gr oups > Details window The window sho ws the members and pro per ties of the selected group . The members appear in a tabl e, with one member per ro w . Click on the “Ne xt 10” or “Previous 10” link to vie w[...]

  • Página 126

    126 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Use the Add Member s button at the top of the Group Members tab le to add a member to the group (see Figure 66 on page 127 ). The right side of the window disp la ys the group’ s proper ties f or outcalling retries. These settings apply only to members with the option [...]

  • Página 127

    Browser user interface 127 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 66 ICB Dashboard – Call-Out Gr oups > Details > Add Members windo w Add members b y entering the phone nu mber directly in the table . The def ault “W ait for Confirmation” option se tting is active (that is , check ed in the correspondin[...]

  • Página 128

    128 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 67 ICB Dashboard – Call-Out Gr oups > Details > Edit Members window Edit the number directly in t he te xt box. Chan ge the “W ait for Confir mation” option b y clicking in the in W ait for Confirmation box. Edit Gr oup Properties – Click on the Modi[...]

  • Página 129

    Browser user interface 129 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 68 ICB Dashboard – Call-Out Gr oups > Deta ils > Modify Group Settings window The Group number is vie w only . The name and parameters can be modified as described in T able 31 on page 126 . Add a Ne w Group Click on the Ne w C all-Out Gr oup[...]

  • Página 130

    130 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 69 ICB Dashboard – Call-Out Gr oups > <New Group> Details windo w This window has the same la yout as the Call-Out Group Details window (see Figure 65 on page 125 ), except here all fi elds are editab le. The Group number pull-down men u shows only a v [...]

  • Página 131

    Browser user interface 131 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 70 ICB Dashboard – P ermanent Conferences List window The Conf erence List table sho w s a lis t of per manent conf erences in the card. This table is similar to t he regular conf erence table (see Figure 36 on page 87 ), e xcept that the time-rela[...]

  • Página 132

    132 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 71 ICB Dashboard – Ne w/Edit P e rmanent Conference window This window is similar to the regular conf erence scheduling window (see “Scheduling window” on page 89 ), e xcept that all time-related fields are not applicab le. The star t ti me and dur ation do [...]

  • Página 133

    Browser user interface 133 Nortel Integrated Co nference Bridge Service Implementation Guide Unlike the regular scheduling windo w that has pop-up sections, all fields and options appear on the basic window . Ta b l e 32 P ermanent Conference New/Edit parameter s Field Description General section Subject Enter text t hat describes the purpo se of t[...]

  • Página 134

    134 Browser user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Backup F or more inf or mation about ho w to use the ICB Dashbo ard to backup files, see “Back up and restore procedures” on page 187 . Reports F or more information about how to use the ICB Das hboard to generate and view repor ts, see “Reports” on page 195 . Ch[...]

  • Página 135

    135 Nortel Integrated Co nference Bridge Service Implementation Guide T elephone user interface Purpose This chapter describes how to use the telephone user interf ace (TUI) to: • in vok e commands dur ing an activ e conference • schedule conf erences and record greetings The chapter contains t he f ollowing sections: • “Overview” on page[...]

  • Página 136

    136 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 — record a conf erence-specific greeting Note: If the second f eature is di sabled b y the administrator (see Figure 57 on page 114 ), the system skips this item and the user directly ente rs the scheduling menu. • Administrator – An administr ator does not sched[...]

  • Página 137

    Telephone user interface 137 Nortel Integrated Co nference Bridge Service Implementation Guide The ICB card selects the por t for diali ng out. The por t is a vailab l e if the number of por ts reser v ed for the conf erence is greater than the number of conf erees that hav e joined the conference . When all reser ved por ts are taken, the por t ca[...]

  • Página 138

    138 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 72 Dial-out A uthorizat ion dialing e xample Note: In BUI, define the same sequenc e as abov e, e xcept do not enter the command code * 0 . If using this f eature a nd Group Call, make sure that the authorization access code precedes the restrict ed DNs in the g[...]

  • Página 139

    Telephone user interface 139 Nortel Integrated Co nference Bridge Service Implementation Guide Group call-out Each ICB card suppor ts up to 64 group call-out lists, each with up to 61 telephone numbers. Each telephone number can be up to 31 digits in length. The administrator defines gr oup call -out lists throu gh the BUI (see “Call-out Gr oups?[...]

  • Página 140

    140 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Group Call-out Smart Retr y – When the chair per son makes a group call-out to the same group f or th e second time, the system repeats the call-out only to numbers that are not connected in the conf erence. The second call-out includes calls to the f ollowing: • n[...]

  • Página 141

    Telephone user interface 141 Nortel Integrated Co nference Bridge Service Implementation Guide Drop all conf erees The chair person can drop all conf erees from the conf erence, e xcept the chair person, b y dialing *90 . The ICB does not i ssue an announcement to the conf erees before disconnecti ng. After the system disconnects the conf erees, th[...]

  • Página 142

    142 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 T ab le 34 shows the commands av ailab l e during a dial-out call (that is, after dialing *0<DN>#). *7 Volume control. *10 All ports mute/u nmute toggle. *19 Self mute/unm ute toggle. *52 Release chairperson control. *60 Count conferees and announ ces names to al[...]

  • Página 143

    Telephone user interface 143 Nortel Integrated Co nference Bridge Service Implementation Guide While the system is announc ing the list of conf er ence par ticipants after the chair person enters *69, t he chair person can e xecute the commands in T able 35 . Features av ailable to all par ticipants Self mute/unm ute toggle All conf erence par tici[...]

  • Página 144

    144 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Adjust the audio v o lume of a conference F ollow the steps in Procedure 19 to adjust the v olume of a conference . Procedure 19 Adjust the conference audio v olume 1 Dial *7 to adjust the volume. Figu re 73 shows how the k eypad oper ates this f e ature. Figure 73 V o[...]

  • Página 145

    Telephone user interface 145 Nortel Integrated Co nference Bridge Service Implementation Guide The help command is sensitiv e to w here the chair person is in the command structure. F or e xample, if the conf erence is in the nor mal activ e state, the chair person hears the main li st of commands after dialing ** . If the chair pers on dials out t[...]

  • Página 146

    146 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 TUI services This sections describes TUI ser vices that are used when there is no activ e conference . Schedule a conference When using the TUI sc heduler , first enter t he TUI user ID and pass word. If a por t is reser ved f or th e TUI, only 31 por ts are av ailable[...]

  • Página 147

    Telephone user interface 147 Nortel Integrated Co nference Bridge Service Implementation Guide • no name f or the name of the conference • no name f or the name of the chair person T o schedule a conf erence through th e TUI, f ollow the steps in Procedure 21 on page 147 . Procedure 21 Use the TUI to schedule a conference 1 Dial the TUI DN. 2 A[...]

  • Página 148

    148 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 22 Use a brandline greeting 1 Dial the TUI DN. Enter y our TUI administrator I D and pass word. The system responds with a menu and step s through how to operate the feature. This procedure is no w complete 2 The chairperson must activ ate the bra ndline gree[...]

  • Página 149

    Telephone user interface 149 Nortel Integrated Co nference Bridge Service Implementation Guide b After scheduling the meeting, dial the TUI Services DN, enter login data, and select “Record customer g reeting” from the v oice menu. The system prom pts you to enter th e re fe re nc e number to identify the meeting. c Enter the number received in[...]

  • Página 150

    150 Telephone user interface 553-3001-358/555-4001-135 Standard 02 .00 July 2006[...]

  • Página 151

    151 Nortel Integrated Co nference Bridge Service Implementation Guide Micr osoft Outlook GUI Purpose This chapter describes how to us e the Microsoft Outlook/Exchange GUI f or audio conf erence scheduling. The chapter contains t he f ollowing sections: • “Overview” on page 151 – introduces the Mi crosoft Outlook GUI and its system requireme[...]

  • Página 152

    152 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Recurrent meetings can be created in Microsoft Outlook. Meetings can be scheduled up to one year in adv ance up to 52 occurrences. Since Microsoft Outlook allows f or l onger scheduling, m eetings scheduled be yond one y ear are not scheduled in the IC B , but are schedul[...]

  • Página 153

    Microsoft Outlook GUI 153 Nortel Integrated Co nference Bridge Service Implementation Guide Procedure 24 ICB Administrator to get the ICB form 1 Enter the time zone f or the ICB card. 2 Define the us ers that will use the Microsoft O utlook GUI. 3 Go to the location of the ICB PC Card and log in using the f ollowing username and pass word: User nam[...]

  • Página 154

    154 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 25 Microsoft Outlook Admini strator to pub lish the ICB files to the Organizational Forms Library 1 Open Microso ft Outlook. 2 Obtain the ICB f or m files from the ICB Administrator . Note: F or each language file (i cbs.oft , icbsjc.oft, and icbsk.oft) y ou are[...]

  • Página 155

    Microsoft Outlook GUI 155 Nortel Integrated Co nference Bridge Service Implementation Guide b Double-clic k ic bf.oft. T he Calendar window open s . Note: Click No if ask ed to Enable macr os . c Choose T ools > Forms > Publish Form As . The Publish Form As window opens. See Figure 74 on page 15 4 for a depiction. d Select Orga nizational For[...]

  • Página 156

    156 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 c Choose T ools > Forms > Publish Form As . The Publis h Form As window opens. See Figure 74 on page 15 4 for a depiction. d Select P ersonal Forms Library in the Look In field. e Enter a Display name and a Form name , such as icbf . f Click Publish . Note: Click Ye[...]

  • Página 157

    Microsoft Outlook GUI 157 Nortel Integrated Co nference Bridge Service Implementation Guide 5 Select Forms in When Pos t i n g to this f older , use . The Choos e Form window opens. 6 Select the library in which the files were published. • If yo u published the f or ms y ours elf , select Per sonal Forms Library in the Look In field. • If the I[...]

  • Página 158

    158 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 3 Choose Prop er ties . The Calendar Properties window opens. 4 Select the Forms ta b. 5 Click Manage . The Forms Manager window opens. 6 Click Set in the left ha lf of the window . The Forms Manager window has two Set bu ttons. The one on the right is inactiv e. 7 Select[...]

  • Página 159

    Microsoft Outlook GUI 159 Nortel Integrated Co nference Bridge Service Implementation Guide Login to the ICB card using Micr osoft Outlook Y ou need to log into the ICB when you are setting up or editing the ICB parameters of a conf erence. Y ou wil l use the same ICB user ID and pass word f or the ICB f or m in Microso ft Outlook that you use f or[...]

  • Página 160

    160 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Scheduling a new conf erence Scheduling windo w Open a ne w appointment in Microsoft Ou tlook after logging into the ICB card. Figure 76 shows the scheduling wi ndow when it first opens after the ICB tab has been selected. Figure 76 Microsoft Outlook ICB tab – Sc hedule[...]

  • Página 161

    Microsoft Outlook GUI 161 Nortel Integrated Co nference Bridge Service Implementation Guide Free P orts view Figure 77 shows the e xpanded schedul ing windo w after clicking on the Free P or ts b utton. The information in this window ref ers to the date set abov e it in the Star t area. The time scale cov ers 12 hours in 15-minute increments. Start[...]

  • Página 162

    162 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Figure 77 ICB tab window – Free P or ts view Options section Figure 78 on page 163 shows the e xpanded windo w after clicking on the Options button. Click on the Arr ow button to move the range. Each click mov es the range f our hours in the direction of the arrow click[...]

  • Página 163

    Microsoft Outlook GUI 163 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 78 ICB tab window – Options section Closes (collapses) the window while still showing the window .[...]

  • Página 164

    164 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 T ab le 39 descr ibes the fiel ds in the Options section. Ta b l e 39 ICB tab window – Op tions section fields Field Description Password se ction User Password Enter an opti onal password for th e conference. If configure d, callers must enter this password to join the[...]

  • Página 165

    Microsoft Outlook GUI 165 Nortel Integrated Co nference Bridge Service Implementation Guide Scheduling complete After scheduling a ne w meeting or m odifying an e xisting meeting, the Confir mation windo w appears to v er ify the entries. The system displa ys the window after it stores the conf erence in the database. See Figure 79 f or an example [...]

  • Página 166

    166 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Only the f ollowing fields can be edited dur ing an activ e conference: • number of par ticipants • duration • add por ts as needed (under the Options section) Once a conf erence is scheduled with the Micros oft Outlook GUI, the ICB tab looks l ik e Figure 80 . The [...]

  • Página 167

    Microsoft Outlook GUI 167 Nortel Integrated Co nference Bridge Service Implementation Guide Setting a delegate user f or Microsoft Outlook Calendar A user can giv e anot her person sharing per m ission to schedule appointments and meeti ngs f or them in th eir calendar . The delegate Outlook f eature allows th e user to specify fo r t he person whe[...]

  • Página 168

    168 Microsoft Outlook GUI 553-3001-358/555-4001-135 Standard 02 .00 July 2006[...]

  • Página 169

    169 Nortel Integrated Co nference Bridge Service Implementation Guide Maintenance Purpose This chapter describes how to mainta in and troubleshoot the ICB card and associated equipment. The chapter contains t he f ollowing sections: • “Maintenance o verview” on page 169 – introduces the maintenance strateg y . • “Updating the Micr osoft[...]

  • Página 170

    170 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 An operator can use the CLI to gener ate repor ts and perf or m por t maintenance. An administr ator can use the CLI to manage system administration, maintenance, and security . T o conduct conf erence OA&M f or an IC B card, connect a ter minal to the RS-232 por t or the Ether[...]

  • Página 171

    Maintenance 171 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 82 ICB card in the Intelligent P eripheral Equipment Module Prob lem solving A prob lem can hav e more than one c ause. T o isolate the cause, a knowledge of ICB oper ation is required. After identifying the cause , the prob lem can be corrected by repl acing d[...]

  • Página 172

    172 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Updating the Micr osoft Outlook GUI ICB form When the ICB f or m needs to be updated in Microsoft Outlook, the form needs to be updated first by the Administrator . The Administrator will then notify users that the ICB f o r m needs to be updated. The procedure to pub lish the new [...]

  • Página 173

    Maintenance 173 Nortel Integrated Co nference Bridge Service Implementation Guide This procedure is no w complete 3 Delete the file Frmcac he.dat . Each upgrade of the ICB firmware comes with upgr aded ICB files, which must be retrie ved and pub lished. See Procedure 45, “Upgrade the ICB fir mware v e rsion, ” on page -218 . F ollow the steps i[...]

  • Página 174

    174 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 3 Set the ne w upg raded f orm as the def ault Calendar f or m. F ollow the steps in Procedure 27 on page 156 . 4 Clear the Microsoft Outl ook forms cache using Procedure 32 on page 17 2 . 5 Schedule a test meeting to ensur e the upgr ade was successful. F ollow the This procedure [...]

  • Página 175

    Maintenance 175 Nortel Integrated Co nference Bridge Service Implementation Guide The self-test chec ks general ICB func tions and determines if they are operating correctly . The checks are useful when first installing the cards, because the card automatically star ts the self-test when inser ted. The self-test provides an immediate indication of [...]

  • Página 176

    176 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 1000) or from the IPE MAP Le vel using the Tst command (CS 2100/Meridian SL-100). Sanity monitoring Sanity monitoring is a background r outine that chec ks the operation of system resources, such as CPU ac tivity and memory allocation. This backg round routine tr ies to restor e no[...]

  • Página 177

    Maintenance 177 Nortel Integrated Co nference Bridge Service Implementation Guide CS 2100/Meridian SL- 100 diagnostic commands Each card perf or ms diagnostic test s as par t of the daily routines. Diagnostic tests can be activ ated fr om the MAP ter minal on the CS 2100/Meridian SL-100. The ICB card appears as an e xtended digital line card to the[...]

  • Página 178

    178 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 CLI command summary Using CLI commands The CLI contains menus and submenus. T o select a menu option, enter the appropriate shor t co mmand or full command at the prompt. When a menu is selected, use the commands in T able 43 to na vigate to other menus or to displa y help . When e[...]

  • Página 179

    Maintenance 179 Nortel Integrated Co nference Bridge Service Implementation Guide T o modify a v alue or attribute of an object, the prog ram responds with a sequence of prompts: on e prompt f or each attrib ute of the object. The prompt defines the name and the current v alue of the attr ibute . Y ou can change the v alue, accept the current value[...]

  • Página 180

    180 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 System Maintenance: SM System T e st: ST T o perform system component tests enter: • i – perform in -ser vice tests that do n ot disrupt s er vice • o – perf or m out-of-s er vice tests Maintenance Repor t Brow ser: MR Browse maintenanc e repor ts by date. F o r more inform[...]

  • Página 181

    Maintenance 181 Nortel Integrated Co nference Bridge Service Implementation Guide ICB fault isolation and correction Alar m clearing procedures f or the IC B are the identical to those f or other IPE cards. T ab le 47 descr ibes ICB ser vice prob le ms and the test procedures used to solv e these problems. Note: If the problem cannot be solv ed aft[...]

  • Página 182

    182 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Card replacement The ICB uses PCMCIA technolog y which enab les the ICB to be remov ed from the IPE shelf indefinite ly without losing the configuration data. Bef ore replacing t he PCMCIA card, back up the data on the card so that it does not ha v e to be re-entered (see “Backup[...]

  • Página 183

    Maintenance 183 Nortel Integrated Co nference Bridge Service Implementation Guide Err or message handling The ICB provides enhanced mess age handling that includes the f ollowing: • Fix ed message format and unique message codes. • Categorization of messages by se verity . • Message analysis tool that provides on- line documentation. • Mess[...]

  • Página 184

    184 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Error messa g e pr ocedures F ollow the steps in Procedure 37 to vie w the on-line error message documentation. Procedure 37 Access the on-line err o r message analysis tool 1 Access the CLI SM direc tory an d enter the f o llowing: SHO The CLI prompts yo u for to enter the error c[...]

  • Página 185

    Maintenance 185 Nortel Integrated Co nference Bridge Service Implementation Guide Action – steps to follow to isolate the proble m and/or fix it. This procedure is no w complete Impact – possible effects of the event. The entire file of error descr iptions is av ailable as a readab le te xt. It can be retriev ed from the ICB to a PC f or off-li[...]

  • Página 186

    186 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 39 Configure error m essa g e filtering 1 Access the CLI SM direc tory an d enter the f o llowing: ERR The CLI displays comman d inputs in the following three sections: •F O R M A T • CLI_SEVERITY_FIL TER • DISK_SEVERITY_FIL TER 2 Y ou can edit t h e v alues as per [...]

  • Página 187

    Maintenance 187 Nortel Integrated Co nference Bridge Service Implementation Guide Adv anced troubleshooting The ICB provides the f ollowing tools f or technicians to troubleshoot and deb ug problems based on error messages: • A utomatic trace back – the system prints an automatic trace bac k list of predefined error codes. This f eature helps s[...]

  • Página 188

    188 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 During the backup process the card remains operational. Ho wev er , the system denies database c hanges and does not acc ept the f ollowing operations: • setting up a ne w conf erence or modifying an e xisting conf erence (allows vie w only) • recording a custom greeting • ma[...]

  • Página 189

    Maintenance 189 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 83 ICB Dashboard – Sc h eduled Backup window The administrator defines the time , destination and contents of the back up. T able 50 describes these three se ctions of the Scheduled Back up window . Ta b l e 50 Scheduled Bac kup parameters Section Description[...]

  • Página 190

    190 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Manual Bac kup An administrator uses the windo w in Figure 84 to perf or m a one-time, manual bac kup . Figure 84 ICB Dashboard – Man ual Backup window Destination Click on an radio button to define the backup destinat ion as follows: • The secondar y PCMCIA device, insert ed i[...]

  • Página 191

    Maintenance 191 Nortel Integrated Co nference Bridge Service Implementation Guide The Destination and Cont ents sections are the same as f or an automatic back up . Open a CLI windo w by clic king on the CLI button on the top frame of the dashboard. Clic k on the Do Backup button to activ ate an immediate backup acco rding to y our selected options[...]

  • Página 192

    192 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 View Bac kup Histor y Log The administrator can vie w a histor y log of past scheduled backups to mak e sure that the bac kups ha v e tak en place as scheduled. The Back up Histor y Log window is a vie w-only window and shows each back up attempt as one line: time stamp (dd/mm/yyyy[...]

  • Página 193

    Maintenance 193 Nortel Integrated Co nference Bridge Service Implementation Guide Procedure 40 Restore the database fr om the secondary PCMCIA 1 Inser t the PCMCIA de vice holding the bac ked-up databa se in the ICB card’ s upper slot. 2 Use the CLI REstor db command in the SMaint dire ctor y . The system prompt s you for the source of the restor[...]

  • Página 194

    194 Maintenance 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The system generates two files that contain inf or mation about the back up progress. The bac kup .log in t he USER director y contains one line f or each of the last bac kups, and restor ati ons, up to a maximum of 20. Each line contains the f ollowing: • a time stamp • whethe[...]

  • Página 195

    195 Nortel Integrated Co nference Bridge Service Implementation Guide Repor ts Purpose This chapter describe s the repor ts that the ICB can generate . The chapter contains t he f ollowing sections: • “Overview” on page 195 – introduces the types of repor ts the ICB can generate and describes where to view them. • “Shor t Connection Rep[...]

  • Página 196

    196 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 T ab le 52 descr ibes the repo r ts that the ICB generates. BUI Report Viewer An administrator can vie w re por ts from the B UI. Click on Vie w a Repor t on the ICB Dashboard to access the Repor t View er window (see Figure 86 ). F ollow the steps in Procedure 42 f or displa ying repo[...]

  • Página 197

    Reports 197 Nortel Integrated Co nference Bridge Service Implementation Guide 4 There are tw o ways to select t he date. a Click on Pre vious Day or Ne xt Da y links. The reques ted repor t will be displa yed. b Click the appropriate date from the drop down bo xes . Then click the Display Report b utton. The requested repor t will be display ed. 5 [...]

  • Página 198

    198 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 SMaint ) and enter the Shor t Connection Repor t command ( sc , SC , or SCon ). Shor t por t occupancy can indicate a fault condition on a por t or can indicate that a user is dialing t he incorrect DN. Set the shor t occupancy range in the System Attrib utes Editor men u, whic h can r[...]

  • Página 199

    Reports 199 Nortel Integrated Co nference Bridge Service Implementation Guide If the repor t does not fit on one window , click on the Ne xt Page b utton to displa y more information. Figure 88 Meetings Log Repor t BU I example CLI Meetings Log Repor t The CLI Meeting Log Br owser men u displa ys a log of conf erence e vents f or a specified date. [...]

  • Página 200

    200 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 15:00:45 (2 220) expand ed 15:01:00 (2 220) entr y: 24 //Conf eree entered conf erence on por t 24// 15:03:23 ( 2230) ch_entr y: 4 //Chair join ed conference on por t 4// 15:03:56 ( 2220) e xit: 14 //Conferee left conference from por t 14// 16:35:09 ( 2230) mmi_op lock //Conference loc[...]

  • Página 201

    Reports 201 Nortel Integrated Co nference Bridge Service Implementation Guide The tabl e in the repor t shows the contents of the Ov erbooking Repor t which the BUI translates fr om a .CSV file . The co lumns in the table are as f ollows: • Hour – The hour of the da y , from 0 to 23 where: — 00 = 0:00 o’clock to 1:00 o’cloc k — 01 = 1:0[...]

  • Página 202

    202 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 17,<max port>,<duration minu tes>,<duration seconds> 18,<max port>,<duration minu tes>,<duration seconds> 19,<max port>,<duration minu tes>,<duration seconds> 20,<max port>,<duration minu tes>,<duration seconds> 21[...]

  • Página 203

    Reports 203 Nortel Integrated Co nference Bridge Service Implementation Guide BUI Billing Report Figure 90 shows ho w the Billing Repor t appears when accessed from the BUI. The tab le in the window sh o w s the contents of the Billing Repor t which the BUI transla tes from the .CSV file . Figure 90 Billing Repor t BUI e xample The “Ev ent” fie[...]

  • Página 204

    204 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 F or example , B0990720.CSV has the Billin g Repor t for J uly 20, 1999 and B1010203.CSV contains the Billing Repor t for F ebr uar y 03, 2001. Note: T o retrie ve billing files, trans f er the files by FTP o ver the TCP/IP LAN using a fix ed pass word. Each Billing Repor t consists of[...]

  • Página 205

    Reports 205 Nortel Integrated Co nference Bridge Service Implementation Guide Note: F or a per manent br idge the m eeting date , star t time, and duration fields are irrele v ant and alw a ys appear as zero . The first line is f or the date, the second line is f or the field names, and all other lines are f or the ev ents. The daily billing repor [...]

  • Página 206

    206 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 A billing file includes the f ollowing records: • Date stamp , for e x ample: D A TE: A ug 7 1998 • Header : time stamp hours , time stamp minutes, time stamp seconds, e v ent, card ID , meeting ID , billing account, date, star t time hours, start time minutes, star t time seconds,[...]

  • Página 207

    Reports 207 Nortel Integrated Co nference Bridge Service Implementation Guide CS 1000 Call De tail Recording The Call Detail Record ing (CDR) f eature enab les the ICB to charge users f or out-going call s based on CDR repor ts the CS 1000 system generates . The repor ts are generated e ven if the call is unans wered. The CS 1000 must ha ve the f o[...]

  • Página 208

    208 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Charge Account feature T o define the CDR with Charge Account f eature, ref er to CS 1000 Call Detail Recording and CS 1000 Features and Services . When a user dials out wit h the Billing and CDR Repor ts option selected, the ICB card take s the Charge Account ke y (consisting of the f[...]

  • Página 209

    Reports 209 Nortel Integrated Co nference Bridge Service Implementation Guide CDR example scenarios The conf erence call was booked using th e BU I by a user whose billing account is 9134513, on Ju ly 19, 1999 at 06:15 p . m., f o r July 20, 1999 from 08:00 a.m. to 09:00 a.m. The number of por ts booked is six. The conf erence call was star ted as [...]

  • Página 210

    210 Reports 553-3001-358/555-4001-135 Standard 02 .00 July 2006 The Maintenance (Error) R epor t appears in the tabl e in this window . The window sho ws the same te xt lines as those generated b y the CLI SMaint/MRepor t command. If the repor t does not fit on one window , click on the Ne xt Pa g e b utton to displa y more information. F or more i[...]

  • Página 211

    211 Nortel Integrated Co nference Bridge Service Implementation Guide Upgrades Purpose This chapter provid es procedures f or upgradi ng y our system to ICB Release 4 from pre vious releases and for upg rading sub-issues of ICB Release 4. The chapter contai ns the f ollowing sections: • “Overview” on page 211 – introduces the ICB upgrade st[...]

  • Página 212

    212 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Note: There is an upgr ade from MICB Release 1 to ICB Release 4 b ut data con v ersion is not suppor t ed. This is the same as a ne w installation. Inser t a PCMCIA card into the top PCMCIA slot accessible through the ICB f aceplate for e xter nal me mor y expansion, ne w voice announ[...]

  • Página 213

    Upgrades 213 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 92 Installing a PCMCIA card into the ICB faceplate slot Ke ycode security A ke ycode protects against unauthor iz ed ICB f eature use. The k eycode restricts upgrades of eit her the number of por ts or application software to a giv en ICB card. Nor tel Networ ks t[...]

  • Página 214

    214 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 K eycodes are not requir ed f or the follo wing: • back up and restore operations • application patching/b ug fix Nor tel Networks provides the cu stomer with a ke ycode to enable installation of any required upg r ade. Enter the k eycode using the Command Line Interf ace from the[...]

  • Página 215

    Upgrades 215 Nortel Integrated Co nference Bridge Service Implementation Guide Upgrade pr ocedures MICB Release 2 or M ICB Release 3 card upgrade Use Procedure 43 to upgr ade your ICB card from Release 2 or Release 3. Proce dure 43 MICB Release 2 or MICB Re lease 3 card upgrade 1 Disable th e operational MICB Release 2 or MICB Release 3 card using [...]

  • Página 216

    216 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 8 When the card is acti v ated as ICB Release 4, enter the CLI an d login as an administrator . Enter : name: admin Pa s sw o r d : <CR> Where CR is an empty password. 9 Inser t the old MICB Release 2 or MICB Release 3 PCMCIA in th e upper so cket . 10 F rom the CLI enter : SMai[...]

  • Página 217

    Upgrades 217 Nortel Integrated Co nference Bridge Service Implementation Guide Figure 93 ICB Dashboard – Car d Upgrade window A por ts upgrade is purchased from No r tel Networks, it comes with a new k eycode f or the card. Follo w the steps in Procedure 44 to perform the por t upgr ade. Procedure 44 Upgrade por ts fr om the adm inistrator’ s I[...]

  • Página 218

    218 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Use a BUI administr ation window f or the upgrade process , which suppor ts both options (see Figure 94 ). The CLI can also be used. F ollow the steps in Procedure 45 to upgrade the ICB fir mware v ersion. Proce dure 45 Upgrade the ICB firmware ver sion 1 Log into the BUI. 2 Click Upg[...]

  • Página 219

    Upgrades 219 Nortel Integrated Co nference Bridge Service Implementation Guide Procedure 46 Firmware upgrade fr om ICB car d upper socket 1 Click on the secondary PCMCIA devi ce radio butt on. 2 Inser t the PCMC IA disk in the upper soc ket of the IC B card. 3 Click on the Up grade & Restar t button. The ICB copies the files from the upper sock[...]

  • Página 220

    220 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 47 Firmware upg ra de using FTP 1 Click on the FTP Ser ver r adio button . 2 Enter the FTP par ameters in the fields the window pro vides as follo ws: a IP address – the remote FTP ser ver where the upgrade files are stored. bP a t h t o f i l e – path of the f older on [...]

  • Página 221

    Upgrades 221 Nortel Integrated Co nference Bridge Service Implementation Guide c Click on the Submit & Continue button. The new single DN access meth od now applies. 4 Instruct users to dial the single DN f or future conf erences. This procedure is no w complete Note: Make sure the notification e- mail content is still valid. Upgrade from a sta[...]

  • Página 222

    222 Upgrades 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Procedure 50 Stand-alone car d to primary car d 1 Access the ICB In stallation Wizard: St ep 1 – Basic Card Setting s window (see “Step 1 – Basic Card Settings” on pag e 73 ). I n the “T yp e” field, select the radio b utton “Dual Card – Primary . ” 2 Click the Submi[...]

  • Página 223

    223 Nortel Integrated Co nference Bridge Service Implementation Guide Appendix A: P ass w ord security Purpose This chapter describes ICB Release 4 passw ord protection and access restrictions. The chapter contains t he f ollowing sections: • “Access permissions” on page 224 – lists the security options av ailab le with the IC B Release 4 s[...]

  • Página 224

    224 Appendix A: Password security 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Access permissions ICB Release 4 provides strict pass word protections and other mechanisms to restrict access from unauthor ized personnel (see Ta b l e 58 ). Ta b l e 58 Access permissions Access type Descrip tion of permissions BUI (HTTP server web access) 1 Lo[...]

  • Página 225

    Appendix A: Passwor d security 225 Nortel Integrated Co nference Bridge Service Implementation Guide Unsuccessful login attempt handling Procedure 52 shows ho w the system handles unsuccessful login attempts . Procedure 52 Unsuccessful login operation 1 No action is required for this procedu r e. However , observe t he activities in the following s[...]

  • Página 226

    226 Appendix A: Password security 553-3001-358/555-4001-135 Standard 02 .00 July 2006 c T elnet acce ss – After the maximum allowed login atte mpts, the system closes the connection. An administ rat or can define the “n ew connection refused” time period. d TUI access – After three un successful login attempts, the syste m This procedure is[...]

  • Página 227

    Appendix A: Passwor d security 227 Nortel Integrated Co nference Bridge Service Implementation Guide Reset passw or ds F ollow the steps in Procedure 53 when a user f orget s their pass word. Procedure 53 Reset f orgotten passw ords 1 The administ rator can reset any BUI pa ssw ord through t he user management BUI. One administra tor can also reset[...]

  • Página 228

    228 Appendix A: Password security 553-3001-358/555-4001-135 Standard 02 .00 July 2006 c W ait f or the f ollowing banner t o appear: ******************************************** ************************ * Running MAIN C ODE!!! * d Enter the token default . This tok en must be entere d within 15 seconds o f the banner ’ s appearance . The rest art[...]

  • Página 229

    Appendix A: Passwor d security 229 Nortel Integrated Co nference Bridge Service Implementation Guide CLI P asswor d Editor editing session The f ollowing is a e xample of using a CLI pass word editing session to change an FTP pass word. T ab le 61 shows the f ont conv entions that the e xample uses. V alues in the examples are not necessar ily the [...]

  • Página 230

    230 Appendix A: Password security 553-3001-358/555-4001-135 Standard 02 .00 July 2006 section [TELNET] Telnet user name: micbtln Telnet password: xyzu1234 Maximum allowed Telnet login attempts: 3 Blocking period (minutes) after login failures: 60 Telnet idle timeout in minutes: 20 Modify, Next section, Cancel: n // next: go to next section section [...]

  • Página 231

    Appendix A: Passwor d security 231 Nortel Integrated Co nference Bridge Service Implementation Guide Application Pr otocol P ort Numbers Ref er to T able 62 f o r the por t num bers to use with the specific application protocol. Ta b l e 62 Application Protocol P or t Numbers Application Port Number Telnet 23 FTP 21, 20 SMTP 25 HTTP 80 Dual ICB car[...]

  • Página 232

    232 Appendix A: Password security 553-3001-358/555-4001-135 Standard 02 .00 July 2006[...]

  • Página 233

    233 Nortel Integrated Co nference Bridge Service Implementation Guide Appendix B: Pr oduct integrity En vir o nmental specifications ICB environmental requ irements meet, or e x ceed, Meridian system requirements. The po wer provided f or each card slot in the IPE module e xceeds the power requirements f or an ICB . T able 63 show s the range of ac[...]

  • Página 234

    234 Appendix B: Product integrity 553-3001-358/555-4001-135 Standard 02 .00 July 2006 Regulatory standards The f ollowing tab les list the safety and electro-magnet ic compatibility regulator y standards f or t he ICB, b y geographic r egion. Specifications f or the ICB meet, or exc eed, the standards listed in the regulations f or these regions. S[...]

  • Página 235

    Appendix B: Product integrity 235 Nortel Integrated Co nference Bridge Service Implementation Guide Electr o-magnetic com patibility (EMC) T ab le 65 lists electro- magnetic emissions regulat ions met b y the ICB card, along with the standar d that lists each regulation. T ab le 66 lists electro- magnetic immunity regulations met b y the ICB card, [...]

  • Página 236

    236 Appendix B: Product integrity 553-3001-358/555-4001-135 Standard 02 .00 July 2006 FCC Compliance This equipment has been test ed and f ound to comply with the limits for a Class A digital de vice pursuant to P ar t 15 of the F CC Rules, and the radio interf erence regulations of the Canadian Depar tment of Communications . These limits are desi[...]

  • Página 237

    Nortel Integrated Co nference Bridge Service Implementation Guide 237 List of terms AC D A utomatic Call Distr ib ution. Browser User Interface An interface that allows the admi nistration of OA&M functions on conferences, users, and card s through a standard web browser. BUI See Browser User Interface. Chairperson DN The directory number the c[...]

  • Página 238

    238 List of terms 553-3001-358/555-4001-135 Standard 02 .00 July 2006 DRAM Dynamic Random Access Memo ry. A high density type of semi-conductor memory. It typically has slow er access time than SRAM and requires external memory refresh circuitry. DSP Digital Signal Processing. A specialized computer chip that performs speedy and complex operations [...]

  • Página 239

    List of terms 239 Nortel Integrated Co nference Bridge Service Implementation Guide flexibility to make changes to the system's parameters without revising the hardware. ISM Incremental Soft ware Management. LAN Local Area Network. LED Light Emitting Diode. LEN Line Equipment Number (CS 2100/ Mer idian SL-100 equiv alent of TN). Main DN The di[...]

  • Página 240

    240 List of terms 553-3001-358/555-4001-135 Standard 02 .00 July 2006 PBX Private Branch Exchange. A telephony sw itch that is privately owned. PCM Pulse Code Modulation. PCMCIA Personal Computer Memory Card In ternational Asso ciation. This organization has defined a credit card sized plug- in board for use in PCs. These cards are t he only way to[...]

  • Página 241

    List of terms 241 Nortel Integrated Co nference Bridge Service Implementation Guide XPM Extended P er ipheral Module .[...]

  • Página 242

    242 List of terms 553-3001-358/555-4001-135 Standard 02 .00 July 2006[...]

  • Página 243

    [...]

  • Página 244

    Nor tel Communicat ion Ser v er 1000 Nor tel Communicat ion Ser v er 2100/Meridian SL-100 Nor tel Integrated Conference Bridge Ser vice Implementation Guide Copyright © 2006 Nortel Netw orks. All r ights r eserve d. The info rmation in this document is subject to c hange without notice. The statements, configurations , technical data, and recommen[...]