Zenith 30009 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Zenith 30009, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Zenith 30009 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Zenith 30009. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Zenith 30009 should contain:
- informations concerning technical data of Zenith 30009
- name of the manufacturer and a year of construction of the Zenith 30009 item
- rules of operation, control and maintenance of the Zenith 30009 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Zenith 30009 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Zenith 30009, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Zenith service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Zenith 30009.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Zenith 30009 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Domestic models 37671 Z enith HydroT ap BC60/85 37601 Z enith HydroT ap BF60 (Ambient) 37691 Z enith HydroT ap B60 37676 Z enith HydroT ap BCD60/85 37606 Z enith HydroT ap BFD60 (Ambient) 37696 Z enith HydroT ap BD60 30009 Z enith HydroT ap HT60 30609 Z enith HydroT ap HTD60 36051 Z enith HydroT ap HT60/85 36651 Z enith HydroT ap HTD60/85 Zenith Hy[...]

  • Page 2

    Page 2 of 20 Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Contents Read These Warnings First . . . . . . . . . . . . . . . . . . . . . . . . . .3 Models covered by these instructions . . . . . . . . . . . . . . . . . .4 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Special to[...]

  • Page 3

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 3 of 20 Read These Warnings First Safety Do not allow young children, handica pped or infirm persons, to use the Z enith HydroT ap without super vision. Refrigerant The Z enith HydroT ap Chilling unit contains 134A refrigerant under pressure. No part of the uni[...]

  • Page 4

    Page 4 of 20 Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 These Installation Instructions cover the entire Z enith HydroT ap range. Use the chart on the left to identify the model you are using: Commercial and Domestic Models: BC = Boiling and Chilled, Filtered, Timer BF = Boiling, Filtered BD = Boiling and Am[...]

  • Page 5

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 5 of 20 In addition to normal tools, the following will be required: • 38mm diameter sheet metal hole punch for sink tops. (not supplied) • 38mm diameter hole saw for timber bench tops. (not supplied) • Nut runner tube spanner (supplied) for fixing tap as[...]

  • Page 6

    Page 6 of 20 Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Installation procedure continued Vent line Chilled line Hot line Front Vent Hot Outlet Step B - Installing the undersink unit (all models) SPECIAL NOTE: The HydroT ap undersink units are heavy , take note of the weights listed in the table on page 4. If[...]

  • Page 7

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 7 of 20 Step D - Connecting the water supply (all models) T o prevent sediment from entering the Z enith HydroT ap at connection, flush water through the supply line thoroughly before connection to the Z enith HydroT ap. Open the access door and check that the [...]

  • Page 8

    Page 8 0f 20 Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 LARGE HOLE 1. Position the Font template (provided) on the bench area. Ensure the position you select is within the length of the supply tube and USB cable fixed to the T ap Head Assembly . These cannot be extended. 2. Check again for correct positionin[...]

  • Page 9

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 9 of 20 Operating the T ap Blue Chilled Water Light On all the time: This indicates that the chilled water temperature is within the usable range. Flashing slowly : This indicates that the chilled wa ter is not at the right tempera ture. Wait up to 20 minutes.W[...]

  • Page 10

    Page 10 of 20 Z enith Hydro T a p Installation and Operating Instructions - 81467 - February 2005 Cleaning Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water . Do not spray water over the tap as it may dama ge the low-volta ge electronics. Undersink units must never be cleaned with wat[...]

  • Page 11

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 11 of 20 Setting the Energy Saver Timer (products with this feature only) Normal Operation (not available on HT boiling only series) Set Time T o change time, press either Mode ∧ or Mode ∨ button until Set Time is on the display screen. Press ∧ Adjust but[...]

  • Page 12

    Page 12 of 20 Z enith Hydro T a p Installation and Operating Instructions - 81467 - February 2005 Auxiliary F an Attachment (excluding HT boiling only models) Auxiliary fan connection Cold water connection Electrical connections The HydroT ap is equipped with an auxiliar y connection point for an exhaust fan on the rear panel close to the cold wate[...]

  • Page 13

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 1 3 of 20 Symptom Possible Cause Solution No LED display , no tap head lights or , no water when ta p levers are operated. No water flow. Slow water recover y after use. Water not hot. Water not chilled. No power . Plug is not located in power socket. T ap loom[...]

  • Page 14

    Page 1 4 of 2 0 Z enith Hydro T a p Installation and Operating Instructions - 81467 - February 2005 Exploded V iew Chiller Module and Spare P arts Item Kit No. Description Item Kit No. Description 1 Z 90613 plumbing fittings kit 14 Z 90056 braided hose 2 Z 90614 safety solenoid kit 15 Z 90635 level sensor kit cold tank BC100/125 3 Z 90615 double so[...]

  • Page 15

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 1 5 of 2 0 Exploded V iew Boiler Module and Spare P arts Item Kit No. Description Item Kit No. Description 1 Z 90613 plumbing and fittings kit 13 Z 90130 clips kit 2 Z 90614 safety solenoid kit 14 Z 90628 stop valve and john guess fittings kit for filter 3 Z 90[...]

  • Page 16

    Page 16 of 2 0 Z enith Hydro T a p Installation and Operating Instructions - 81467 - February 2005 Exploded V iew HT Series Boiling Only and Spare P arts ITEM KIT NO. DESCRIPTION 1 Z 90656 Plumbing and Fittings kit 2 Z 90614 Safety Solenoid Kit 3 Z 90657 Single Solenoid Kit 4 Z 90658 Gasket and Elbow Kit BC 100/125 5 Z 90579 Overload Kit 6 Z 90618 [...]

  • Page 17

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 17 of 2 0 Notes[...]

  • Page 18

    Page 18 of 2 0 Z enith Hydro T a p Installation and Operating Instructions - 81467 - February 2005 Notes[...]

  • Page 19

    Z enith Hydro T ap Installation and Opera ting Instructions - 81467 - February 2005 Page 19 of 2 0 Notes[...]

  • Page 20

    Z enith Hydrotap - Installation & Operating Instructions - 81438 - June 2004 Page 20 of 20 Head Office Parex Appliances 103 Central Park Dr Henderson Auckland Email: info@parex.co.nz Website:www.parex.co.nz T elephone (0 9) 836 6566 Facsimile (09) 836 6033 # Warranty Information The Z enith appliance you have chosen is precision-built from the [...]