York YZE024 THRU 060 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York YZE024 THRU 060, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York YZE024 THRU 060 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York YZE024 THRU 060. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York YZE024 THRU 060 should contain:
- informations concerning technical data of York YZE024 THRU 060
- name of the manufacturer and a year of construction of the York YZE024 THRU 060 item
- rules of operation, control and maintenance of the York YZE024 THRU 060 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York YZE024 THRU 060 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York YZE024 THRU 060, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York YZE024 THRU 060.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York YZE024 THRU 060 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM HEA T PUMPS 15 SEER – R-410A MODELS: YZE024THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuous pr oduct improvement, spec ifications are subject to change without notice. Visit us on the web at www .york.com Additional rati ng information can be foun d at www .ari.org/aridirectory LISTED ISO 9001 Certified Qu[...]

  • Page 2

    2 Johnson Controls Unitary Products 246750-YTG-L-0408 All dimensions are in inches. They are subject to change without notice. Certified dimensions wil l be provided upon request. * Adapter fitting required for 1-1/8” line set. Physical and Electrical Dat a MODEL YZE0241 1 YZE0361 1 YZE0481 1 YZE0601 1 Unit Supply V oltage 208-230V , 1 φ, 60Hz N[...]

  • Page 3

    Johnson Controls Unitary Produ cts 3 246750-YTG-L-0408 PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refri gerant for the condenser , the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional charge requ ired for specific evaporator coil in th e system using the above table. 3[...]

  • Page 4

    4 Johnson Controls Unitary Products 246750-YTG-L-0408 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL W ST AGE RA TED CFM NET MBH SENSIBL E SEER EER YZE0241 1 A V24 17 – 1 535 18.6 13.6 15.00 13.00 2 800 24.0 18.6 12.50 A V36 17 – 1 535 18.6 13.6 15.00 13.00 2 800 24.0 18.6 12.50 MV12B 17 FC/MC30B 1[...]

  • Page 5

    Johnson Controls Unitary Produ cts 5 246750-YTG-L-0408 COOLING CAP ACITY - With V a riable Speed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING ST AGE RA TED CFM NET MBH SEER EER TOT AL SENSIBLE YZE0241 1 PV8*A12 FC/MC/PC/UC30A 14 1 430 17.3 1 1.5 14.00 12.60 2 750 23.0 18.2 12.00 PV9*A12 FC/MC/PC30A 14 1 625 18.5 14.4 14.[...]

  • Page 6

    6 Johnson Controls Unitary Products 246750-YTG-L-0408 YZE0361 1 P(C,V)9*C16 FC/MC/PC/UC48C 21 1 640 24.2 16.2 15.50 12.70 2 1200 35.2 25.1 12.00 PV8*C16 FC/MC/PC/UC48C 21 1 780 25.0 18.9 15.00 12.85 2 1200 34.8 26.8 12.00 PV8*C20 FC/MC/PC/UC48C 21 1 800 25.2 19.1 15.25 12.90 2 1200 35.0 26.8 12.00 P(C,V)9*D20 FC/MC/PC/UC48D 24 1 770 25.0 18.8 15.50[...]

  • Page 7

    Johnson Controls Unitary Produ cts 7 246750-YTG-L-0408 HEA TIN G CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER MODEL COIL 1 MODEL HEA TING ST AGE RA TED CFM NET MBH HSPF COP @ 47 47 OD 17 OD YZE0241 1 A V24 - 1 650 19.0 - - 3.30 2 775 24.0 15.6 8.25 3.36 2 650 23.2 14.6 8.05 3.12 A V36 - 1 650 19.0 - - 3.30 2 775 24.0 15.6 8.25 3.36 2 6[...]

  • Page 8

    8 Johnson Controls Unitary Products 246750-YTG-L-0408 ** Refer to Q uick Selectio n Char t for specific furnace match-up. YZE0601 1 A V60 - 1 1200 37.6 - - 3.26 2 1900 55.0 32 .4 8.05 3.50 2 1200 50.0 29 .8 7.90 3.22 F2FV060 - 1 1200 37.6 - - 3.26 2 1900 54.0 32 .2 8.00 3.50 2 1200 50.0 29 .8 7.90 3.22 MV20D FC/MC60D 1 1200 37. 6 - - 3.26 2 1900 54[...]

  • Page 9

    Johnson Controls Unitary Produ cts 9 246750-YTG-L-0408 YZE0361 1 P(C,V)9*B12 FC/MC/PC3 5B 17 1 650 2 3.0 - - 3.54 2 1200 33.0 20.8 8.50 3.70 2 650 29.4 19.6 8.35 3.30 PV8*B16 FC/MC/PC35B 17 1 650 23.0 - - 3.54 2 1200 33.0 21.0 8.50 3.70 2 650 29.4 19.6 8.35 3.30 P(C,V)9*C16 FC/MC/PC35C 21 1 650 23.0 - - 3.54 2 1200 33.0 21.0 8.50 3.70 2 650 29.4 19[...]

  • Page 10

    10 Johnson Controls Unitary Products 246750-YTG-L-0408 YZE0481 1 PV8*C20 FC/PC/UC60C 21 1 860 31.2 - - 3.56 2 1610 48.0 27.8 8.35 3.96 2 860 44.5 26.2 8.30 3.66 P(C,V)9*C20 FC /PC/UC60C 21 1 870 31.2 - - 3.56 2 1590 48.0 27.8 8.40 3.96 2 870 44.5 26.2 8.30 3.66 P(C,V)9*D20 FC/MC/PC/UC60D 24 1 855 31.2 - - 3.56 2 1620 48.0 27.8 8.40 3.96 2 855 44.5 [...]

  • Page 11

    Johnson Controls Unitary Produ cts 11 246750-YTG-L-0408 ACCESSORIES* TXV Kits - 1 TVM9 series thermal expansion val ves precisely meter refrigerant for optimu m performance. Bonnet Sensor (2SB137 00124) - The bonnet sensor is u sed to sense plenum temperatur e, and is optional with a gas or oi l back-up heat source. Compatible only with 13 SEER and[...]

  • Page 12

    12 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining th e performance with other indoor sec tions . NOTE: For dry bulb temperatures dif f erent than those listed (bet ween 73-87 F), sensible capacity increa se s by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 13

    Johnson Controls Unitary Produ cts 13 246750-YTG-L-0408 Multipliers for determining the performance with ot her indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decre ases by 1060 BTUH per 10 00 CFM per[...]

  • Page 14

    14 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining th e performance with other indoor sec tions . NOTE: For dry bulb temperatures dif f erent than those listed (bet ween 73-87 F), sensible capacity increa se s by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 15

    Johnson Controls Unitary Produ cts 15 246750-YTG-L-0408 Multipliers for determining the performance with ot her indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decre ases by 1060 BTUH per 10 00 CFM per[...]

  • Page 16

    16 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining th e performance with other indoor sec tions . NOTE: For dry bulb temperatures dif f erent than those listed (bet ween 73-87 F), sensible capacity increa se s by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 17

    Johnson Controls Unitary Produ cts 17 246750-YTG-L-0408 Multipliers for determining the performance with ot her indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decre ases by 1060 BTUH per 10 00 CFM per[...]

  • Page 18

    18 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining th e performance with other indoor sec tions . NOTE: For dry bulb temperatures dif f erent than those listed (bet ween 73-87 F), sensible capacity increa se s by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 19

    Johnson Controls Unitary Produ cts 19 246750-YTG-L-0408 Multipliers for determining the performance with ot her indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decre ases by 1060 BTUH per 10 00 CFM per[...]

  • Page 20

    20 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining the perfo rman ce with other indoor section. NOTE: KW RA TING IS FOR OUT DOOR AND INDOOR UNITS. LOW CFM HEA TING PERFORMA NCE DA T A - LOW CFM 1-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0241 1 INDOOR COIL MODEL NO . FC/MC/PC36B + MV12B AIR TEMP . ENTERING OUTDOOR [...]

  • Page 21

    Johnson Controls Unitary Produ cts 21 246750-YTG-L-0408 Multipliers for de termining the performa nce with other i ndoor section. NOTE: KW RA TING IS FOR OU TDOOR AND INDOOR UNITS. HIGH CFM HEA TIN G PERFOR MA NCE DA T A - HIGH CFM 2-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0241 1 INDOOR COIL MODEL NO. FC/MC/PC36B + MV12B AIR TEMP . ENTERING OUT[...]

  • Page 22

    22 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining th e performance with other indoor sec tions . NOTE: KW RA TING IS FOR OUT DOOR AND INDOOR UNITS. LOW CFM HEA TING PERFORMA NCE DA T A - LOW CFM 1-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0361 1 INDOOR COIL MODEL NO . FC/MC/PC48C + MV16C AIR TEMP . ENTERING OUTDOO[...]

  • Page 23

    Johnson Controls Unitary Produ cts 23 246750-YTG-L-0408 Multipliers for de termining the performa nce with other i ndoor sections. NOTE: KW RA TING IS FOR OU TDOOR AND INDOOR UNITS. HIGH CFM HEA TIN G PERFOR MA NCE DA T A - HIGH CFM 2-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0361 1 INDOOR COIL MODEL NO. FC/MC/PC48C + MV16C AIR TEMP . ENTERING OU[...]

  • Page 24

    24 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining the perfo rman ce with other indoor sections. NOTE: KW RA TING IS FOR OUT DOOR AND INDOOR UNITS. LOW CFM HEA TING PERFORMA NCE DA T A - LOW CFM 1-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0481 1 INDOOR COIL MODEL NO . FC/MC/PC60D + MV20D AIR TEMP . ENTERING OUTDOOR[...]

  • Page 25

    Johnson Controls Unitary Produ cts 25 246750-YTG-L-0408 Multipliers for de termining the performa nce with other i ndoor sections. NOTE: KW RA TING IS FOR OU TDOOR AND INDOOR UNITS. HIGH CFM HEA TIN G PERFOR MA NCE DA T A - HIGH CFM 2-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0481 1 INDOOR COIL MODEL NO. FC/MC/PC60D + MV20D AIR TEMP . ENTERING OU[...]

  • Page 26

    26 Johnson Controls Unitary Products 246750-YTG-L-0408 Multipliers for determining the perfo rman ce with other indoor sections. NOTE: KW RA TING IS FOR OUT DOOR AND INDOOR UNITS. LOW CFM HEA TING PERFORMA NCE DA T A - LOW CFM 1-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0601 1 INDOOR COIL MODEL NO. MC61D + MV20D AIR TEMP . ENTERING OUTDOOR UNIT A[...]

  • Page 27

    Johnson Controls Unitary Produ cts 27 246750-YTG-L-0408 Multipliers for de termining the performa nce with other i ndoor sections. NOTE: KW RA TING IS FOR OU TDOOR AND INDOOR UNITS. HIGH CFM HEA TIN G PERFOR MA NCE DA T A - HIGH CFM 2-ST AGE OPERA TION OUTDOOR UNIT MODEL NO. YZE0601 1 INDOOR COIL MODEL NO. MC61D + MV20D AIR TEMP . ENTERING OUTDOOR [...]

  • Page 28

    Subject to change without notice. Printe d in U.S.A. 246750-YTG-L-0408 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 246750-YTG-K-0108 Johnson Controls Unit ary Products 5005 Y ork Drive Norman, OK 73069 NOTES[...]