York TCGD12 THRU 60 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York TCGD12 THRU 60, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York TCGD12 THRU 60 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York TCGD12 THRU 60. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York TCGD12 THRU 60 should contain:
- informations concerning technical data of York TCGD12 THRU 60
- name of the manufacturer and a year of construction of the York TCGD12 THRU 60 item
- rules of operation, control and maintenance of the York TCGD12 THRU 60 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York TCGD12 THRU 60 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York TCGD12 THRU 60, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York TCGD12 THRU 60.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York TCGD12 THRU 60 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL GUIDE SPLIT -SYSTEM A IR CONDITIONERS 13 SEER – R-22 MODELS: TCGD12 THRU 60 (1 THRU 5 NOMINA L TONS, 1 PHASE) Due to continuous produc t impr ovement, specifications are subject to change without notice. V isit us on th e web at www .york.com A dditional rating informa tion can be fo und at w ww .ahridirectory . org LISTED ISO 9001 Cert[...]

  • Page 2

    400034-YTG-B-0708 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to cha nge without notice. Ce rtif ied dimensio ns will be provide d upon request. Physical and Electr ical Dat a MODEL TCGD12 S21S2(H) TCGD18 S21S2(H) TCGD24 S21S2(H) TCGD30 S21S2( H) TCGD3 6 S21S2( H) TCGD4 2 S21S2(H) TCGD48 S21S2(H) TCGD60 S21S2 [...]

  • Page 3

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 3 Additional R-22 Charge / Orifice Size for V arious Matched Systems Outdoor Unit TCGD12 S21S2(H) TCGD18 S21S2(H) TCGD24 S21S2(H) TCGD30 S21S2(H) TCGD36 S21S2(H) TCGD42 S21S2(H) TCGD48 S21S2(H) TCGD60 S21S2 Required Orifice or TXV 1,2 0.041 / 2A 0.052 / 2A 0.059 / 0.061 / 2A 0.065 / 2A 0.073 / 2A[...]

  • Page 4

    400034-YTG-B-0708 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refr igerant for th e condenser , the smallest evaporator and 15 feet of inter- connecting line tubing. 2. V erify the TXV or orifice and additional charge required for s pecific evaporator coil in t he system using the abo[...]

  • Page 5

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 5 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT A L SENS. 13 SEER AC WITH MA TCGD18S21S2(H) MA08B 17 F C/MC18B 600 18.0 12.6 13.00 1 1.00 MA08B 17 FC/MC24B 600 18 .0 12.6 13.00 1 1.00 TCGD24S21S2(H) MA08B 17 F C/MC3[...]

  • Page 6

    400034-YTG-B-0708 6 Johnson Controls Unitary Products — = Not applicable. 13 SEER AC WITH AHP / SHP / F*FP TCGD12S21S2(H) AHP18 17 – 450 12.0 8.9 13.00 1 1.00 TCGD18S21S2(H) AHP18 17 – 650 18.0 12.6 13.00 1 1.00 AHP24 17 – 650 18.0 12.6 13.00 1 1.00 F4FP024 18 – 600 18.0 12.6 1300 1 1.00 TCGD24S21S2(H) AHP30 17 – 795 24.0 17.3 13.00 1 1[...]

  • Page 7

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT A L SENS. TCGD12S21S2(H) 450 - 750 14,17 FC/MC/PC18 450 12.0 9.1 13.00 1 1.00 450 - 750 14 HC18 450 12.0 9.1 13.00 1 1.00[...]

  • Page 8

    400034-YTG-B-0708 8 Johnson Controls Unitary Products 1 COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT A L SENS. 13 SEER AC WITH V ARIABLE SPEED FUR NACES 2 TCGD18S21S2(H) PV8*A12 FC/MC/PC18A 14 600 18.0 13.0 14.00 12.00 PV9*A12 FC/MC/PC18A 14 600 18[...]

  • Page 9

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 9 TCGD36S21S2(H) PV8*A12 FC/MC/PC37A 14 1200 35 .2 25.0 14.00 12.00 PV9*A12 FC/MC/PC37A 14 1200 35 .2 25.0 14.00 12.00 PV8*B16 FC/MC/PC43B 17 1200 35.4 25.0 14.00 12.00 PV8*C16 FC/MC/PC43C 21 1200 35 .4 25 .0 14.00 12.00 PV8*C20 FC/MC/PC43C 21 1200 35 .6 25 .0 14.00 12.00 P(C,V)9*B12 FC/MC/PC43B [...]

  • Page 10

    400034-YTG-B-0708 10 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. HARD ST ART KIT - Required when using TXV i ndoor coil. Also, provides increased starting torque for a reas with low voltage. OFF CYCLE TIMER DELA Y - Provides a 5-minute off cycle to prevent rapid recycling of the compressor . ROOM [...]

  • Page 11

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 11 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p[...]

  • Page 12

    400034-YTG-B-0708 12 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 13

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 13 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p[...]

  • Page 14

    400034-YTG-B-0708 14 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 15

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 15 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p[...]

  • Page 16

    400034-YTG-B-0708 16 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those liste d (bet ween 73-87 F), sensible capacit y incr eases by 1060 BTUH per 1000 CFM per deg ree abo ve the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM[...]

  • Page 17

    400034-YTG-B-0708 Johnson Controls Unitary Produ cts 17 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than t hose liste d (between 73-87 F), sensible cap acity incr eases by 1060 BTUH per 1000 CFM per degr ee above the listed temperature and decreases by 1060 BTUH per 1 000 CFM p[...]

  • Page 18

    Subject to change without notice. Printe d in U.S.A. 400034-YTG-B-0708 Copyright © 2008 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 400034-YTG-A-0408 Johnson Controls Unitary Product s 5005 Y ork Drive Norman, OK 73069 Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif fere[...]