York PAC036 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York PAC036, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York PAC036 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York PAC036. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York PAC036 should contain:
- informations concerning technical data of York PAC036
- name of the manufacturer and a year of construction of the York PAC036 item
- rules of operation, control and maintenance of the York PAC036 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York PAC036 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York PAC036, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York PAC036.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York PAC036 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL GUIDE 50 Hz SINGLE P ACKAGE ELECTRIC / ELECTR IC AIR-COOLED AIR CONDITIONER MODELS: P AC036 THRU 060 (3 THRU 5 NOMINA L TONS, 3 PHASE) 036-21346-001 Rev. A (202) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE DESCRIPTION These units are designed for outdoor installation and offer electric cooling with an ele ctric heat[...]

  • Page 2

    036-21346-001 Rev. A (202) 2 Unitary Products Group 1. Rated in accordance with ARI S tandard 1 10, utilization range “A”. 2. Dual element fuses or HACR circuit br eaker . 3. Rated under standard A.R.I. conditions of 80º DB/67º WB indoor , 95º outdoor . 4. Other temperature ratings of wire will have diff erent rated ampacities. Refer to NE C[...]

  • Page 3

    036-21346-001 Rev. A (202) Unitary Products Group 3 CAP ACITY & PERFORMANCE DA T A UNIT MODEL NUMBER COOLING CAP ACITY 95 °F UNIT CHARGE WEIGHT HCFC-22 RA TED CFM SENSIBLE TOT AL RA TIO SOUND RA TING P AC036H1081A 33,000 3.7 Lbs. 1,200 0.74 8.4 P AC048H1081A 47,000 7.0 Lbs. 1,500 0.68 8.4 P AC060H1081A 55,000 7.6 Lbs. 1,600 0.65 8.4 BLOWER PER[...]

  • Page 4

    036-21346-001 Rev. A (202) 4 Unitary Products Group FIELD INST ALLED ACCESSORIES Refer to price manual for specific model numbers: S tart Assist Kit, T ime Delay Kit, Electric Heater Kit and W all Thermostat. Electric Heater Kit - A vailable in 3 diff erent Kw capac- ities (5, 10, 15 Kw). W all Thermostat - The units are designed to operat e with 2[...]

  • Page 5

    036-21346-001 Rev. A (202) Unitary Products Group 5 COOLING PERFORMANCE DA T A NOTE: ALL CAP ACITIES ARE NET WITH INDOOR FAN HEA T ALREADY DEDUCTED A T 125 0 BTUH/1000 CFM. KW RA TING IS FOR OUTDOOR UNIT ON L Y . Unit Model Number P AC036H1081A INDOOR AIR AMBIENT TEMPERA TURE ENTERING CONDENSING COIL 85º 95º 105º 1 15º 125º CAP ACITY MBTUH CAP[...]

  • Page 6

    036-21346-001 Rev. A (202) 6 Unitary Products Group NOTES[...]

  • Page 7

    036-21346-001 Rev. A (202) Unitary Products Group 7[...]

  • Page 8

    Subject to change without notice. Printe d in U.S.A. 036-21346-001 Rev. A (202) Copyright © by York International Corp. 2002. All r ights rese rved. Supersedes: T-734 Rev. 3, 530.10-TG2YI (89 9) Unitary 5005 Norman Product s Y ork O K Group Drive 73069[...]