York K3EU180A50 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York K3EU180A50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York K3EU180A50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York K3EU180A50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York K3EU180A50 should contain:
- informations concerning technical data of York K3EU180A50
- name of the manufacturer and a year of construction of the York K3EU180A50 item
- rules of operation, control and maintenance of the York K3EU180A50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York K3EU180A50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York K3EU180A50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York K3EU180A50.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York K3EU180A50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    GENERAL This completely assembled blower unit is manufactured under ISO 9002 Quality System Certification and includes a well- insulated cabinet, a DX cooling coil with copper tubes and alu- minum fins, an expansion valve, a distributor , throwaway fil- ters, a centrifugal blower , a blower motor , a blower motor contactor , an adjustable belt driv[...]

  • Page 2

    LIMIT ATIONS These units must be installed in accordance with applicable na - tional, local and municipal safety codes. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer's ex - pense. Refer to T able 2 for Unit Application Data. LOCATION This blower unit is not design[...]

  • Page 3

    VERTICAL/HORIZONT AL INST ALLATION The unit is shipped for vertical installation with a vertical air dis - charge as shown in Figure 1, but may be converted to other ar - rangements per the following instructions. 1. Remove the panels from the blower section. 2. Remove the four Phillips machine bolts that hold the coil and blower sections together [...]

  • Page 4

    NOTE: T o minimize the possibility of system failure due to dirt and moisture, a filter-drier must be installed in each liq - uid line as close to the evaporator as possible. Filter- driers are not supplied with the evaporator blowers. They are supplied with the matching condensing sec - tions. The temperature required to make or break a brazed joi[...]

  • Page 5

    4. All pulleys are factory aligned. 5. All supply air motor pulleys are factory set at two “turns open.” After the supply air blower motor is operating, adjust the resis - tances in both the supply and the return duct systems to bal - ance the air distribution throughout the conditioned space. The job specifications may require that this balanc[...]

  • Page 6

    6 Unitary Products Group 035-12124-000 Rev . A (0501)I SUPPL Y AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM AIRFLOW ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (KW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW 4800 CFM 5400 CFM 6000 CFM 6600 CFM 7200 CFM 600 0[...]

  • Page 7

    Unitary Products Group 7 035-12124-000 Rev . A (0501) FIG 7 - UNIT DIMENSIONS AND CLEARANCES UNIT ACCESSORIES •ELECTRIC HEA TER Add 15" (381mm) to Unit Height when using 10, 16, 26 or 36kW Heater •SUPPL Y AIR PLENUM Add 27" (686mm) to Unit Height when used •BASE Add 24" (610mm) to Unit Height when used MINIMUM CLEARANCES (in./m[...]

  • Page 8

    MOTOR SPECIFICATIONS •1450 RPM •380/415-3-50 •Solid base •56 Frame •Inherently protected •Permanently lubricated ball bearings MAINTENANCE FILTERS — The filters must be replaced as often as necessary to assure good air flow and filtering action. EV APORATOR COIL — Do not allow dirt to accumulate on the evaporator coil or other parts[...]