The rules should oblige the seller to give the purchaser an operating instrucion of York H4TS024, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York H4TS024 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York H4TS024. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York H4TS024 should contain:
- informations concerning technical data of York H4TS024
- name of the manufacturer and a year of construction of the York H4TS024 item
- rules of operation, control and maintenance of the York H4TS024 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York H4TS024 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York H4TS024, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York H4TS024.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York H4TS024 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL GUIDE STEAL TH SPLIT -SYSTE M AIR CONDITIONERS 15 + SEER MODELS: H4TS024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuous pr oduct improvement, sp ecifications are subject to change without n otice. Visit us on the web at www .york.com for the most up-to-date technical information. Additional rating informa tion can be foun d at www .ar[...]

  • Page 2

    036-21023-005 Rev. A (0802 ) 2 Unitary Products Group PHYSICAL AND EL ECTRICAL DA T A MODEL H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 UNIT SUPPL Y VOL T AGE 208/230-1-60 NORMAL VOL T AGE RANGE 1 187 to 252 MIN. CIRCUIT AMP ACITY 13.4 15.3 18.6 32.8 35.3 MAX. OVERCURRENT DEVICE AMPS 2 20 25 30 50 60 COMPRESSOR TYPE BRISTOL TS COMPRESSOR AMPS RA TED LO[...]

  • Page 3

    036-21023-005 Rev. A (0802) Unitary Products Group 3 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. ACCESSORIES* Enhanced Coil Guard - An enhanced coil gua rd which offers superior protection from hail and other types of damage is available. * For t[...]

  • Page 4

    036-21023-005 Rev. A (0802 ) 4 Unitary Products Group COOLING CAP ACITY - V ariable Speed Furnace UNIT MODEL V ARIABLE SPEED FURNACE MODEL WC O I L M O D E L COOLING ST AGE (# CYL) RA TED CFM NET MBH SE ER EER TOT AL SENS. H4TS024 P1XUB12V055 17 G1UA036S17 1 600 12.6 10.2 15.0 13.7 2 820 24 .4 17.2 1 1.7 G1F A036S17 1 600 12 .6 10.2 15.0 13. 7 2 82[...]

  • Page 5

    036-21023-005 Rev. A (0802) Unitary Products Group 5 H4TS036 P1XUB12V055 P1DUB16V080 17 17 G1UA048S17 1 750 20 .0 16.0 14.5 13. 4 2 1 150 34.8 26.0 1 1.0 G1F A048S17 1 750 20 .0 16.0 14.5 13. 4 2 1 150 34.8 26.0 1 1.0 G2FD036S17 1 750 20 .0 16.0 14.5 13. 4 2 1 150 34.8 26.0 1 1.0 G2FD046S17 1 750 20.0 16 .0 14. 5 13.4 2 1 150 34.8 26.0 1 1.0 P1XUC [...]

  • Page 6

    036-21023-005 Rev. A (0802 ) 6 Unitary Products Group Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - LOW CFM 1-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS024S06 INDOOR COIL MODEL NO. G2FD036S17+N1VSB 12 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 550 600 650 ID DB (°F) 85 80 75 70 85 80 [...]

  • Page 7

    036-21023-005 Rev. A (0802) Unitary Products Group 7 Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - HIGH CFM 2-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS024S06 INDOOR COIL MODEL NO. G2FD036S17+N1VSB12 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 750 800 850 ID DB (°F) 85 80 75 70 85 80 7[...]

  • Page 8

    036-21023-005 Rev. A (0802 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - LOW CFM 1-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS030S06 INDOOR COIL MODEL NO. G2FD042S21+N1VSC 16 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 600 650 700 ID DB (°F) 85 80 75 70 85 80 [...]

  • Page 9

    036-21023-005 Rev. A (0802) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - HIGH CFM 2-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS030S06 INDOOR COIL MODEL NO. G2FD042S21+N1VSC16 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 950 1000 1 100 ID DB (°F) 85 80 75 70 85 8[...]

  • Page 10

    036-21023-005 Rev. A (0802 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - LOW CFM 1-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS036S06 INDOOR COIL MODEL NO. G2FD048S21+N1VSC 16 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 700 750 850 ID DB (°F) 85 80 75 70 85 80[...]

  • Page 11

    036-21023-005 Rev. A (0802) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - HIGH CFM 2-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS036S06 INDOOR COIL MODEL NO. G2FD048S21+N1VSC16 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1200 1300 ID DB (°F) 85 80 75 70 85[...]

  • Page 12

    036-21023-005 Rev. A (0802 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - LOW CFM 1-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS048S06 INDOOR COIL MODEL NO. G2FD048S24+N1VSD 20 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1450 1600 1750 ID DB (°F) 85 80 75 70 85[...]

  • Page 13

    036-21023-005 Rev. A (0802) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - HIGH CFM 2-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS048S06 INDOOR COIL MODEL NO. G2FD048S24+N1VSD20 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1450 1600 1750 ID DB (°F) 85 80 75 70 85 [...]

  • Page 14

    036-21023-005 Rev. A (0802 ) 14 Unitary Products Group Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - LOW CFM 1-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS060S06 INDOOR COIL MODEL NO. G2FD061H24+N1VSD20 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1200 1300 ID DB (°F) 85 80 75 70 85[...]

  • Page 15

    036-21023-005 Rev. A (0802) Unitary Products Group 15 Multipliers for determining th e performance with other indoor sections. COOLING PERFORMANCE DA T A - HIGH CFM 2-CYLINDER OPERA TION AIR CONDITIONER MODEL NO. H4TS060S06 INDOOR COIL MODEL NO. G2FD061H24+N1VSD20 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1700 1900 2000 ID DB (°F) 85 80 75 70 85 [...]

  • Page 16

    Subject to change without notice. Printe d in U.S.A. 036-21023-005 Rev. A (0802) Copyright © by York International Corp. 2002. All right s reserved. Supersedes: 036-21023-004 Rev. A (1000) Unitary 5005 Norman Product s Y ork O K Group Drive 73069 MA TCHING INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWN[...]