York F*FV manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York F*FV, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York F*FV one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York F*FV. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York F*FV should contain:
- informations concerning technical data of York F*FV
- name of the manufacturer and a year of construction of the York F*FV item
- rules of operation, control and maintenance of the York F*FV item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York F*FV alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York F*FV, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York F*FV.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York F*FV item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS HEA T PUMP MODELS: F*FP V ARIABLE SPEED MODEL: F*FV Due to continuou s produc t improvement, spe ci fic a tions are subjec t to ch a nge without notic e. V isit us on the web at www .york.com Additional rati ng information ca n be found at www .ari.org/ar[...]

  • Page 2

    295421-YTG-B-0707 2 Unitary Products Group DIMENSIONS Model Dimensi ons Wiri ng K .O. s 1 1. Actual conduit size is shown in p arenthesis. 2. All models only available with factory inst alled horizont al drain pan. Refrigerant Connection s Line Size ABC DE F JK Liquid V apo r Height Width Depth Power Control F4FP024H06T2* 40-3/4 18 22 12-1/ 8 14-7/[...]

  • Page 3

    295421-YTG-B-0707 Unitary Products Group 3 COIL TECHNICAL DA T A Models Application Refrige rant Connection Ty p e Face Area (Sq. Ft.) Deep Rows Fins Per Inch Coil Slab Size Tu b e Geometry Tu b e Dia. Fin. T ype Metering Device HW F4FP024H06T2A A/C & HP Sweat 3.40 2 14 14 17.5 1 x .886 3/8 Enhanced TXV -2A F4FP024H06T2B A/C & HP 3.40 2 14 [...]

  • Page 4

    295421-YTG-B-0707 4 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. VERTICAL SUSPENSION KIT - The suspension kit is designed to be used with all sizes of fan coi l unit s whenever the application requires vertical suspension of the unit. ELECTRIC HEA TERS - Models shown under Electrical Data include sequencers a[...]

  • Page 5

    295421-YTG-B-0707 Unitary Products Group 5 EXTENDED AIR FLOW DA T A 1 FOR 208 VOL T - HEA T PUMP MODELS 1. Includes Return Air Filter and L argest Electric Heate r . All F*FP series air handler uni t s are UL Listed up to 0.50" w . c. external static pressure, inclu ding air filter , wet coil, and largest KW size heat er . Models Blower Motor [...]

  • Page 6

    295421-YTG-B-0707 6 Unitary Products Group EXTENDED AIR FLOW DA T A - F4FV V ARIABLE SPEED MODELS Normal The normal setting provides a 30-second ra mp-up from zero airflow to full capacity and a 30-second ramp -down from full capacity back to zero airfl ow. Whenever there is a change in airflow mode, such as a call for cooling or a change from low [...]

  • Page 7

    295421-YTG-B-0707 Unitary Products Group 7 Physical and Electrical Dat a MODEL F4FP024H06T2* F4FP030H06T2* F 4FP036H06T2* F4FP040H06T2 * – Blower - Diameter Width 10x6 10x8 10x8 10x8 – Motor HP 1/4 1/3 1/2 1/3 – Nominal RPM 1075 1075 1075 1075 – Vo l t a g e 208/230 AMPS Full Load 1.6/1.4 2.5/2.2 3.3/2.9 2.5/2.2 – Locked Rotor 3.3/2.9 6.2[...]

  • Page 8

    295421-YTG-B-0707 8 Unitary Products Group ELECTRICAL DA T A - 1 ∅ - 208/230 - 1-60 Models Heater 1 Model 1. 0 or as follows: 0 = No Breaker , 1 = Breaker . MAX. ST A TIC & MIN. CFM T otal Heat 2 2. See Conversion T able below: KW St agin g 3 3. If first st age heat or 66 is connected to W1, other wise refer to this t able. KW MBH W1 Only W2 [...]

  • Page 9

    295421-YTG-B-0707 Unitary Products Group 9 ELECTRICAL DA T A - 1 ∅ (SINGLE SOURCE POWER SUPPL Y) - COPPER WIRE Models Heater Model 1 1. 0 or 1 as follows: 0 = No Breaker , 1 = Breaker Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 2 Amps/T ype 2. OCP = Over Current Protection device, must be HACR type Circuit Breaker or T ime De[...]

  • Page 10

    295421-YTG-B-0707 10 Unitary Products Group ELECTRICAL DA T A - 1 Ø (MUL TI-SOURCE POWER SUPPL Y) - COPPER WIRE Models Heater Model Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 1. OCP = Over Current Protection device, must be HACR ty pe Circuit Breaker or Ti me Delay fuse. 2. 2HK16501906B only applies to F4FP036 Model. 75°C Wire Size - A WG C[...]

  • Page 11

    295421-YTG-B-0707 Unitary Products Group 11 FIELD WIRING CONNECTION - COOLING ONL Y FIEL D WIRING CONNECTION - WITH HEA TER KIT ELECTRICAL DA T A - 3 ∅ - (SINGLE SOURCE POWERSUPPL Y) - COPPER WIRE Models Heater Models Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amp s 1. O.C.P . = Over Current Protection device, must be HACR type Circuit Br [...]

  • Page 12

    295421-YTG-B-0707 12 Unitary Products Group FIELD WIRING CONNECTIONS - COOLING MO DELS WITH ELECTRIC HEA T WIRING FIELD WIRING CONNECTIONS - SINGLE ST AGE HEA T PUMP NOTES: 1. “Y” T erminal on Air Handle r Control Board must be connected for full CFM and applications requiring 60 second Blower Off Del ay for SEER enhancement. 2. 1 Optional Dehu[...]

  • Page 13

    295421-YTG-B-0707 Unitary Products Group 13 TYPICAL INST ALLA TION TYPICAL APPLICA TIONS[...]

  • Page 14

    295421-YTG-B-0707 14 Unitary Products Group NOTES[...]

  • Page 15

    295421-YTG-B-0707 Unitary Products Group 15 NOTES[...]

  • Page 16

    Subject to change without notice. Printe d in U.S.A. 295421-YTG-B-0707 Copyright © by York International Corp. 2007. All righ ts reserved. Supersedes: 295421-YTG-A-0507 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES[...]