Yamaha DRCX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Yamaha DRCX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Yamaha DRCX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Yamaha DRCX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Yamaha DRCX should contain:
- informations concerning technical data of Yamaha DRCX
- name of the manufacturer and a year of construction of the Yamaha DRCX item
- rules of operation, control and maintenance of the Yamaha DRCX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Yamaha DRCX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Yamaha DRCX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Yamaha service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Yamaha DRCX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Yamaha DRCX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User ’ s Manual ENGLISH E YA MAHA NETWORK BOARD E74-V er . 3.07 Ether net SRCD/SRCP ERCX/SRCX/DRCX[...]

  • Page 2

    [...]

  • Page 3

    INTRODUCTION Thank you for purchasing the Ethernet unit for the Y AMAHA single-axis/dual-axis ro- bot controllers SRCP/SRCD/ERCX/SRCX/DRCX series. This is an optional unit to allo w connecting Y AMAHA single-axis/dual-axis robot con- trollers SRCP/SRCD/ERCX/SRCX/DRCX series (hereafter called "controller") to the widely used Ethernet which[...]

  • Page 4

    MEMO[...]

  • Page 5

    Contents Contents Chapter 1 Cautions T o Ensure Safety ................................... 1 1-1 Basic safety points ............................................................................. 2 1-2 System design safety points .............................................................. 2 1-3 Installation and wiring safety points ..............[...]

  • Page 6

    MEMO[...]

  • Page 7

    CHAPTER 1 1 Cautions T o Ensure Safety[...]

  • Page 8

    2 CHAPTER1 Cautions T o Ensure Saf ety 1-1 Basic safety points Besides reading this instruction manual and the controller user’ s manual, also be sure to handle the equipment correctly while paying suff icient a ttention to safety . Points regarding safety in this instr uction manual only list items in volving this product. Please refer to the co[...]

  • Page 9

    3 CHAPTER1 Cautions T o Ensure Saf ety 1-3 Installation and wiring safety points ! CAUTION Always cut off all power to the contr oller and the overall system bef ore attempting installation or wiring jobs. This will pre vent possible electrical shocks. After the controller has been on f or a while, some points in the controller may be e xtremely ho[...]

  • Page 10

    4 CHAPTER1 Cautions T o Ensure Saf ety 1-4 Start-up and maintenance safety points ! CAUTION Nev er attempt to disassemble the robot or contr oller . When a robot or contr oller component must be re paired or replaced, contact us for details on how to perf orm the servicing . ! CAUTION Always cut off all power to the contr oller and the overall syst[...]

  • Page 11

    5 CHAPTER1 Cautions T o Ensure Safety 1-6 W arranty The Y AMAHA robot and/or related product you hav e purchased are warranted against the defects or malfunctions as described belo w . W arranty description : If a failure or breakdown occurs due to defects in materials or workmanship in the genuine parts con- stituting this Y AMAHA robot and/or rel[...]

  • Page 12

    6 CHAPTER1 Cautions T o Ensure Safety Y AMAHA MOT OR CO., L TD. MAKES NO O THER EXPRESS OR IMPLIED W AR- RANTIES, INCLUDING ANY IMPLIED W ARRANTY OF MERCHANT ABILITY OR FITNESS FOR ANY P AR TICULAR PURPOSE. THE W ARRANTY SET FOR TH ABO VE IS EXCLUSIVE AND IS IN LIEU OF ALL EXPRESSED OR IMPLIED W ARRANTIES, INCLUDING W ARRANTIES OF MERCHANT ABILITY [...]

  • Page 13

    CHAPTER 2 2 Ethernet Unit[...]

  • Page 14

    8 CHAPTER2 Ethernet Unit 2-1 Ethernet unit features Ethernet is the network most commonly used by of fice equipment today . This Ethernet unit is an optional device for connecting to controllers o ver the Ethernet. The communications protocol utilizes TCP/IP which is a standard Internet protocol so PCs and business computers with Internet access or[...]

  • Page 15

    9 CHAPTER2 Ethernet Unit 2-2 How data is exchanged The follo wing is a brief explanation to help understand ho w information is exchanged ov er the Ethernet with the other devices, such as between the controller and PC. In the communications method called TCP/IP , an IP address is assigned to each device connected on the network. The IP addr ess is[...]

  • Page 16

    10 CHAPTER2 Ethernet Unit 2-3 How to connect to Ethernet The Ethernet unit employs 10B ASE-T specifications, so the controller connects by a cable to the HUB. Use UTP cables (unshielded twisted-pair cables) or STP cables (shielded twisted-pair cables) for category 3 or higher , with straight-through wiring specifications. T o connect to the Etherne[...]

  • Page 17

    11 CHAPTER2 Ethernet Unit 2-4 Making system settings for the controller (server) A minimum of IP address, subnet mask and gatew ay settings must be made so that the controller will be correctly identified and ackno wledged on Ethernet. These settings are made from the TPB and enabled after the contr oller is restarted. 2-4-1 V alidating the Etherne[...]

  • Page 18

    12 CHAPTER2 Ethernet Unit 2-4-2 Setting the IP address This follo wing explains how to set the IP address. The IP address is a number unique to each device and identif ies that device from among many other de vices connected on the network. The IP addr ess of one de vice must not be the same number as another device so use caution when setting the [...]

  • Page 19

    13 CHAPTER2 Ethernet Unit ! CAUTION When connecting the contr oller on an already existing network, always check with the network super visor before making IP ad dress, subnet mask and gateway set- tings. MEMO MEMO The IP address is separated into network address and host address sections. The network address section is extracted from the IP addres[...]

  • Page 20

    14 CHAPTER2 Ethernet Unit 2-4-3 Setting the subnet mask This follo wing explains how to set the subnet mask. The subnet mask is a numerical address used to subdivide the netw ork into smaller parts. 1) Press F3 (SYS) on the initial menu screen. 2) Press F4 (next) to switch the function display and then press F2 (OPT). 3) Press F4 (next) again and t[...]

  • Page 21

    15 CHAPTER2 Ethernet Unit 2-4-4 Setting the gateway The follo wing explains how to set the g ateway . Basically this is specifying the router IP address. The router is a de vice relaying information from a certain network to a dif ferent network when two or mor e networks are present. 1 ) Press F3 (SYS) on the initial menu screen. 2) Press F4 (ne x[...]

  • Page 22

    16 CHAPTER2 Ethernet Unit ! CAUTION Any appropr ia te gateway addr ess can be used as long as the network is not con- nected to other networks. (How ever , use an IP address that has not yet been as- signed to other devices.) When connecting the contr oller on an already existing network, always check with the network super visor before making IP a[...]

  • Page 23

    17 CHAPTER2 Ethernet Unit 2-5 Making the PC settings (client) The settings for the device (PC) are also essential f or correctly exchanging information with the controller . A basic method for setting a computer using W indows 98 is de- scribed below . If using a device ha ving a different OS (operating system) or TCP/IP protocols, refer to the use[...]

  • Page 24

    18 CHAPTER2 Ethernet Unit 6) Set the gatew ay under the “Gatew ay” tab screen. Enter the IP address of the router serving as the gate way and then click the “ Add” button. When finished making the settings, click the “OK” button a fe w times and a message appears asking if it is okay to restart the PC. Click the “OK” button to resta[...]

  • Page 25

    19 CHAPTER2 Ethernet Unit 2-6 Checking the connection with “ping” Once you are finished with the netw ork settings, make a check with “ping” to confirm that you can send and receiv e data normally . Here, “ping” is a network diagnostic tool incorporated into the OS as a standard feature. A simple description of how to use “ping” inc[...]

  • Page 26

    20 CHAPTER2 Ethernet Unit 2-7 Using TELNET Communicating by TELNET (r emote operation) allo ws loading and editing point or program data and operating the robot just the same if connected through an RS-232C port. Commands are easy to understand because they are identical to RS-232C communica- tion commands. 2-7-1 Difference between TELNET and RS-23[...]

  • Page 27

    21 CHAPTER2 Ethernet Unit 2-8 TELNET dedicated parameters T o ensure reliable TELNET communications that match customer system settings, the Ethernet unit can be used with TELNET dedicated parameters e xplained in this section. 2-8-1 TELNET dedicated parameters: Setup method 1 T o set up TELNET dedicated parameters, use the procedure below . (User [...]

  • Page 28

    22 CHAPTER2 Ethernet Unit 2-8-2 TELNET dedicated parameters: Setup method 2 T o set the user name and password for login, use the procedure below . 1) Perform step 1 through step 3 in “2-8-1 TELNET dedicated parameters: Setup method 1”. 2) Select F1 (LIN) to display the submenu. Press F1 (CHEK) to set whether or not to make the LOGIN check. Pre[...]

  • Page 29

    23 CHAPTER2 Ethernet Unit 2-8-3 Description of TELNET dedicated parameters ■ PORT (TCP port No.) Use this parameter to set the TCP port No. of the controller . The port No. set here is specified along the IP address w hen the client connects to the controller . Input range : 0 to 65535 Default v alue : 23 (TELNET port) * If any v alue other than [...]

  • Page 30

    24 CHAPTER2 Ethernet Unit ■ LIN-CHEK (Login check) Use this parameter to set whether or not to check the connection while the client is connected to the controller . If making a login check is selected here, then alw ays make the user name and the password check when connected to the controller . In this case, the client cannot con- nect to the c[...]

  • Page 31

    25 CHAPTER2 Ethernet Unit 2-9 TELENET communication commands 2-9-1 Communication command specifications TELNET communication commands are broadly classified into tw o types. One type is commands that instruct the Ethernet unit to process the command task. The other type is robot control commands to access the controller and perform sophisticated pr[...]

  • Page 32

    26 CHAPTER2 Ethernet Unit 2-9-2 Ethernet unit control commands These commands instruct the Ethernet unit to process the command task. Unlike the robot control commands described later on, the Ethernet unit control commands may not require a start code ‘@’ (=40H) at the beginning of the command. (1) LOGOUT BYE This command terminates TELNET comm[...]

  • Page 33

    27 CHAPTER2 Ethernet Unit 2-10 Making a connection with TELNET .EXE A typical W indows PC has a TELNET ter minal called TELNET .EXE as standard equip- ment. The follo wing briefly explains ho w to make a connection using TELNET .EXE. Preconditions are a controller IP address of 192.168.0.2, a port No. of 23, and all other dedicated TELNET parameter[...]

  • Page 34

    28 CHAPTER2 Ethernet Unit 6) An OK message appears on the screen when the login check ends normally . From no w on, commands and messages can be e xc hanged with the robot. 7) When the task or job is complete, enter the LOGOUT or BYE command to can- cel the connection with the controller and press the Enter ke y . 8) A message appears announcing th[...]

  • Page 35

    29 CHAPTER2 Ethernet Unit 2-1 1 Other operating tasks 2-1 1-1 Displaying the MAC address Use the follo wing procedure to display the MA C address of the Ethernet unit. 1) Press F3 (SYS) on the initial menu screen. 2) Press F4 (next) to switch the function display and then press F2 (OPT). 3) Press F2 (MA C). 4) The MA C address appears on the screen[...]

  • Page 36

    30 CHAPTER2 Ethernet Unit 2-1 1-2 Displaying the version of the Ethernet unit 1) Press F3 (SYS) on the initial screen. 2) Press F4 (next) to switch the function display and then press F2 (OPT). 3) Press F3 (VER). 4) The version of the Ethernet unit no w ap- pears on the screen. Press ESC to return to the pre vious screen. [MENU] select menu 1EDIT2O[...]

  • Page 37

    31 CHAPTER2 Ethernet Unit 2-12 Message List 2-12-1 Error messages The follo wing error messages in volving the Ethernet system ha ve been added. Message net link error Cause • TELNET connection terminated due to error . • A TELNET dedicated parameter is set so as to stop operation during logout processing. Solution • T o end the TELNET commun[...]

  • Page 38

    32 CHAPTER2 Ethernet Unit 2-13 T roubleshooting When problems occur , then troubleshoot as needed by using the following information as a guide. Be sure to always also refer to sections on “T roubleshooting” in the controller user’ s manual as well as the instruction manual for the other par ty’ s equipment such as PCs or HUB peripheral dev[...]

  • Page 39

    33 CHAPTER2 Ethernet Unit Checkpoints • Check the settings after referring to “2- 4-2 Setting the IP address” p. 10, “2-4- 3 Setting the subnet mask” p. 12, and “2-4-4 Setting the gateway” p. 13. • Try substituting the Ethernet unit. • Check that the IP address of the controller you are attempting to connect with is correct. • C[...]

  • Page 40

    34 CHAPTER2 Ethernet Unit Checkpoints • Check the TELNET parameter to find if it was set to stop operation during logout. • Check the TELNET parameter to find if communication status is longer than the time set for timeout. • Check if a cable is detached or power supply for the HUB or other equipment is off. • Check if operating problems ar[...]

  • Page 41

    35 CHAPTER2 Ethernet Unit 2-14 Specifications 2-14-1 Ethernet unit specifications ! CAUTION W e use an FL HUB (made b y Phoenix Contact) to check operation. Using this HUB is r ecommended if constr ucting y our own system. HUBs generally a vailable on the market ar e not designed for use in locations suc h as factories, so some HUBs are vulnerab le[...]

  • Page 42

    36 CHAPTER2 Ethernet Unit 2-14-2 Modular connector The pin layout for the modular connector used in the Ethernet unit is sho wn below . 12345678 Pin No Signal name 1 TD+ 2 TD- 3 RD+ 4 N.C 5 N.C 6 RD- 7 N.C 8 N.C *Pins 4, 5, 7, 8 are not used.[...]

  • Page 43

    37 CHAPTER2 Ethernet Unit 2-14-3 UTP (STP) cable The Ethernet cables are standardized by ANSI/TIA/EIA568A. T o av oid miswiring and malfunction, we recommend using cables conforming to this standard. When using 10B ASE-T cables, it must hav e transmission characteristics of category 3 or higher . ■ Straight-through cable Use this cable to connect[...]

  • Page 44

    38 CHAPTER2 Ethernet Unit 2-15 Supplement 2-15-1 T ypical network systems How a particular user builds up a network system depends on factors such as the scale of the network. ■ Example 1 In this example, se veral controllers are operated from one PC using one HUB. 10BASE-T cable 10BASE-T cable PC Controller HUB PC Controller 1 Controller 2 Contr[...]

  • Page 45

    39 CHAPTER2 Ethernet Unit ■ Example 2 In this e xample, many controllers are operated with the HUBs connected in cascade. * The cascade port, also sometimes called an UPLINK port or MDI port is used when connecting multiple HUBs in cascade. Straight-through cables are used to connect the cascade ports of the HUBs together . Howe ver , crossover c[...]

  • Page 46

    40 CHAPTER2 Ethernet Unit ■ Example 3 In this example, the control PC and the controllers are separated from each other . * The 10B ASE-5 cable has a maximum length of 500 meters. Ho wever , this distance can be extended to a maximum of 2.5 kilometers by connecting cables together and using repeaters, etc. PC Controller T er minator T er minator [...]

  • Page 47

    41 CHAPTER2 Ethernet Unit ■ Example 4 In this example, a dial-up router is used to oper ate a controller in a remote location ov er an ISDN line. [[Page 39]] Controller Controller ISDN public telephone line Head office F actor y DSU DSU ISDN dial-up router ISDN dial-up router HUB HUB PC PC ISDN dial-up router ISDN dial-up router ISDN dial-up rout[...]

  • Page 48

    42 CHAPTER2 Ethernet Unit ■ Example 5 In this example, a controller in a remote location is centr all y managed ov er the Internet. Use of a fire wall (defense mechanism to keep out intruders) is recommended to maintain security . F actor y 2 Controller Controller Internet F actor y 2 F actor y 1 Router Router Head office Router Router HUB HUB PC[...]

  • Page 49

    43 CHAPTER2 Ethernet Unit 2-15-2 Description of terminology ■ TCP/IP (T ransmission Control Protocol/Internet Protocol) TCP/IP is a general term for a group of standard protocols for carrying out communi- cations ov er the Internet centering around TCP and IP protocols. Computers and PCs capable of accessing the Internet all use TCP/IP pr otocols[...]

  • Page 50

    44 CHAPTER2 Ethernet Unit ■ IP address The IP address is a unique number assigned to each device to identify that de vice on the network and pre vent the same number from being used by dif ferent de vices. (Mor e accurately , an IP addr ess is assigned to each network interface, since once PC may sometimes be installed with multiple network inter[...]

  • Page 51

    45 CHAPTER2 Ethernet Unit ■ Subnet mask The subnet mask is used to separate the IP address into a network address section and a host address section. The netw ork address bit is set to 1, and the host address bit is set to 0. The subnet mask, just like the IP address is expressed as a decimal number of 32 bits (4 bytes) with each byte separated b[...]

  • Page 52

    Dec. 2007 Ve r. 3.07 This manual is based on V er. 3.07 of Japanese manual. © Y AMAHA MOTOR CO., L TD. IM Company All rights reserved. No part of this publication may be reproduced in any form without the permission of Y AMAHA MOTOR CO., L TD. Information furnished by Y AMAHA in this manual is believed to be reliable. Howe ver, no responsibility i[...]