Wybron Optic manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Wybron Optic, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wybron Optic one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Wybron Optic. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Wybron Optic should contain:
- informations concerning technical data of Wybron Optic
- name of the manufacturer and a year of construction of the Wybron Optic item
- rules of operation, control and maintenance of the Wybron Optic item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wybron Optic alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wybron Optic, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wybron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wybron Optic.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Wybron Optic item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TRANSI TION CMY Fiber Optic Illuminator CMY with TW -White light with WT -White light Transition User Manual[...]

  • Page 2

    2 Table of Contents Declaration of Conformity………………………………………………..3 Safety Notice………………………………………………………………4 Introduction to Transition…………………………………………………7 Transition Quick Start configuration…………………………………[...]

  • Page 3

    3[...]

  • Page 4

    4 Safety Notice SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual gives step-by-step instructions for preparation, setup, and operation of the Transition TM Fiber Illuminator. There is a potential risk of fire, electric shock or injury to persons if the product is not used as instructed. The Transition Fiber Illuminator is to be [...]

  • Page 5

    5[...]

  • Page 6

    6 Intro to the Transition[...]

  • Page 7

    7 Transition Product Introduction Wybron is pleased to announce the introduction of the Transition fiber illuminator. Contained within a small easy to integrate package and ultra bright fiber optic illuminator, the Transition brings quality and durability to your venue. In addition, the Transition is designed to be an integral component of Wybron?[...]

  • Page 8

    8 Transition Quick Start Configuration 1. Connect the Equipment a) Connect fiber bundle common end to the Transition output port. b) Connect the Transition to a DMX source with a 5-pin cable c) Connect to AC power (110 – 240 VAC 50/60Hz) 2. Control Transition with DMX Leave Transition addressed at channel 1 (factory default) DMX channel 1 control[...]

  • Page 9

    9 Transition Specifications Model 8670: Transition CMY Fiber Illuminator Features:  No lamp optimization required  Rubber feet for cabinet or countertop installation  Durable all metal construction  Output supports fiber bundles ranging from 17 – 30 mm dia.  High output 150W UHI compact arc source  Legendary Wybron Reliability D[...]

  • Page 10

    10 Fixture Setup and Configuration Installing the Lamp DANGER: Disconnect fixture from line voltage before replacing lamp. CAUTION: Lamp and lamp mounting surfaces are hot! Allow lamp to cool 10 minutes before replacing Lamp Specifications Lamp socket / base: G22 Part# UHI-S150DW/A/UVP Lamp, Eurospot UHI Series 3000K 150W UHI-S150DM/A/UVP Lamp, Eur[...]

  • Page 11

    11 Maximum ambient temperature (t a ) may not exceed 40˚C (104˚F) Keep objects at least 2” (50mm) from sides of the fixture. Keep objects at least 6” from the top of the fixture. Cabinet or Closet Mounting The Transition may be mounted in a closet or cabinet on a hard surface such as wood, laminate, or metal. Do not mount the Transition on so[...]

  • Page 12

    12 DMX / RDM Setup and Operation Controls and Indicators Transition controls and indicators as follows: o A three character seven-segment display o 4 push buttons: Menu , ( + ), ( - ), and Enter o Power (red) and signal (green) indicator LED’s The seven-segment display shows the address number (1-508) and the Demo mode (OFF, d1, d2). It also disp[...]

  • Page 13

    13 Display Messages Normal Messages 680 Displayed for 1 second after power is applied. This is the RDM manufacturer device identification number Ini Indicates that the unit is initializing the diachronic filters 001 – 508 The first DMX address Transition will respond to. Adr Top menu item. Pressing ‘Enter’ here will allow the current DMX addr[...]

  • Page 14

    14 EEP Err An attempt to write to non-volatile memory failed. The unit will continue to respond to commands. SEr Err The RDM unique ID has been corrupted. The unit will operate normally but should not be used in an RDM environment. Contact dealer or factory for assistance. RDM Functionality Transition is compliant with the RDM v1.0 standard and can[...]

  • Page 15

    15 Service Lamp Replacement DANGER: Disconnect fixture from line voltage before replacing lamp. WARNING: Lamp and lamp mounting surfaces are hot! Allow lamp to cool before replacing.  Disconnect fixture from AC power.  Remove lamp plate by removing mounting screws as shown in figure 1.1 and pull lamp assembly straight back from reflector. [...]

  • Page 16

    16 Cleaning the Color Filters It is recommended that the color filters be only cleaned with low-pressure air without disassembling the color filters from the motor shafts. If the color module must be disassembled to clean the dichroic filters take careful note of the location and offset height of the individual color flags. Color filters must be re[...]

  • Page 17

    17 Flash Reprogramming Transition firmware can be updated as new firmware versions become available through the DMX/RDM port using an Infogate gateway and the Infogate application. Transition firmware updates can be found at www.wybron.com . Specific instructions for upgrading firmware in Transition and other Wybron equipment can be found in the In[...]

  • Page 18

    18 Warranty Information WYBRON, INC. warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system (up to a maximum of 18 months from delivery) its products will be free from defects in materials and workmanship under normal use and servic[...]

  • Page 19

    19 Figure 2.1 Figure .2[...]