Williams 1773511 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Williams 1773511, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Williams 1773511 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Williams 1773511. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Williams 1773511 should contain:
- informations concerning technical data of Williams 1773511
- name of the manufacturer and a year of construction of the Williams 1773511 item
- rules of operation, control and maintenance of the Williams 1773511 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Williams 1773511 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Williams 1773511, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Williams service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Williams 1773511.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Williams 1773511 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation Instructions and Owner’s Manual Direct-Vent Wall Furnace - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GA S • Open all windows. • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in y[...]

  • Page 2

    Table of Contents General Information a nd Technical Data This furnace is design certif ied to ANSI Z21.86-2004 / CSA 2.32-2004 Gas–Fire d Gravity and Fan-Type, Direct -Vent Wall Furnaces as a Fan-Type Direct-Vent Wa ll Furnace to be inst alled on an outsi de wall according to these in structions. Any alteration of the original design, installed [...]

  • Page 3

    2 Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLE D • Due to high temperatures, the furnace should be located out of traffic and away from any combustible materials such as furniture and draperies. • Children and adults sho uld be alerted to the hazards of high surface temperatures a nd should stay awa[...]

  • Page 4

    Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas dealer can give you a ”Scratch and Sniff” pa mphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnorm al odor, call your LP Gas dealer. • If you are not qualified, do not light pilot lights, perform se[...]

  • Page 5

    Installation Installation should be done by a QUALIFIED SERVICE TECHNICIAN. The furnace must be located on an outs ide wall. Wall Installation 4 Minimum clearances from combustible materials: WARNING: For the installati on of this furnace, the following items must be used in the vent air intake system: • Unit to the top surface of carpeting, tile[...]

  • Page 6

    5 A. Clearance above grade, verand a, porch, deck or balcony 12-inches (30 cm ) minimum. (3) B. Clearance to window or do or that may be opened 12- inches (30 cm) minimum. (3) C. Clearance to permane ntly closed window minimum 12- inches (30 cm) recomme nded to prevent condensation on wind ow. D. Vertical clearance to ventilated soffit located abov[...]

  • Page 7

    6 5. Install the supporting bracket to the wall; insert the air pipe in the wall through the hole provided in the support bracket . Place the round adhesive gasket around the hole so that the air pipe rem ains in position. (Figure 3) 6. Attach the supporting bracket with the screws. If possibl e use self-tapping scre ws. If self -tapping screws can[...]

  • Page 8

    7 12. Remove the vent cap an d drill all the necessary holes (diame ter ¼ inch for the screw fittings provided with th e furnace). 13. Relocate the vent cap and attach it with the screws. (Figure 7) 14. Attach the female end of the three-prong cord to t he receptacle lo cated near the bottom of the furnace. 15. Connect the gas supply line. A gas s[...]

  • Page 9

    8 ressure at the correct value Gas Conversions Converting to another gas type mu st be performed by a qualified service technician. If the type of the gas supplied to the dwelling is not the same type as your furnace (natural or LPG gas), it must be converted. It will be necessary to do the following: 1. Change nozzle. a. Remove the screw indicated[...]

  • Page 10

    9 Gas Supply Check all local codes for requirements, esp ecially for the size and type of gas supply line required. On natural gas line s less than 15” (380 mm) long, use 1/2” tube; on longer runs, use 3/4” iro n tube or equal. On LP Gas lines please consult LP Gas supplier. Installing a New Main Gas Shutoff Valve Each furnace should have its[...]

  • Page 11

    10 First Firing the Furnace Start the furnace following the instructions given in the “Opera ting Instructions”. The first lighting may be difficult becaus e of the air trapped in the gas line s. During initial firing of the fu rnace, resi dual manufacturing grease will bake out and smoke will occur which is not a health dan ger. To prevent nui[...]

  • Page 12

    11 Electrical Wiring Diagram Key: EV, EV1 Gas Valve 1 (Safety S hutter) Vanne Gas 1 (Securite’) lamme ermostat ffe 0 size – 4A mbustion 2 pcs) p) ) V itch e’ - Hiver sse Ventil. re EV2 Hi-Lo Flame Operator O perateur Haute-Basse F M Fan Motor Moteur du Ventilateur M1 Overhe at Th Thermostat de Surchau M2 Fan Thermostat Thermostat de Ventilati[...]

  • Page 13

    12 Operating Instructions Before operating the furnace, re fety information in this manual . ad carefully all wa rnings and sa A. Thi s appli ance do es not hav e a pil o t whic h m ust Fol l ow the gas suppli er' s instr uct ion s. be li ght ed by m eans of t he pi ezo i gni t er i nstal l ed - I f you c annot reach y our gas suppli er , c al[...]

  • Page 14

    13 WHA T TO DO IF T HE RED LA MP I S LIT Thi s appl i ance has an el ect roni c f lam e superv i si on dev ic e. I f t he f lam e di sappears the gas f l ow w ill b e a uto matic ally shut of f and the red l am p wil l l i ght inst ead of t he green one. T he appl i anc e w ill a ttemp t to re ligh t if yo u d o ONE of the f oll owing: A. B. Turn t[...]

  • Page 15

    14 Servicing All servicing activities must be performed by a qualified se rv ice t chnicia n or a service agency. The hom e owner may not e hecking and Adjusting the Gas Manifold Pressure manifold pressures as shown in “Technical Data”. It is roceed as follows: the HI mode. g scre w “C” (pressure regulator) to t he value given in “Technic[...]

  • Page 16

    Annual Maintenance Requirements 1. Clean fan blades. 2. Clean air blower. 3. Check and clean sili cone red pipes. 4. Check air flow switch. 5. Clean and check exhaust flue pipe a nd air intake pipe. Check red O-Ring G asket (NRNG003). If it is damaged, replace it. 6. Check for ga s leaks on all conne ctions. 7. Check and adjust gas pre ssure. 15 Ga[...]

  • Page 17

    16 Programmable Timer The programmable timer allows precise operating an d timing control and is standard on thi s furnace. (Figure 10) Overview The programmable timer has the following feature s: • Long life lithium battery • Daily and weekly programs • One minute minimum switching time • Quick progressi on • Sixteen programs (8 on and 8[...]

  • Page 18

    17 Setting and Adjustment 1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 E EE  1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 0 :00  1 2 3 4 5 6 7 0 :00  ☼ 1 Initial Conditions A. Set the Setting/Regulator switch (Figure 10-B) in RUN position (ce nter). Press the Reset button R. The display will flash. B. With the Setting/Regulator switch sele ctor in pos[...]

  • Page 19

    18 D. Press the Day Setting, (1……7, Figure 11-D) bu tton to program another day or block of days. E. To set further programs repeat steps item B through D above. NOTE: When the same ON and O FF times are desired for different days of the week, the setting procedu re may be simplified. • 1-2-3-4-5 (from Monday through Friday) • 1-2-3-4-5-6 ([...]

  • Page 20

    19 Troubleshooting Starting Sequence (Electrical) Step 1 1. Check L1 – L2 (Supply 120 V, 60 Hz) 2. Check M9 (Main fuse) Troubleshooting Step 1 Point 1 (L1-L2) No voltage (120 V). Check the electrical supply line, wirin g and connectio ns. Point 2 (M9) Fuse damaged. Check the electrical supply line and repla ce the fuse. Summer Mode Step 2 3. Chec[...]

  • Page 21

    20 Troubleshooting Step 3 Point 5 (Z1) Z1 is open and no ignition. Check wiring and conn ections. If everything is okay, replace the switch. Point 7 (M2) M2 is closed and fan thermostat temperature is lower than 104 °F. Check wiring and co nnections. If they are okay, replace the thermostat. Step 4 8. Check Z9 (Room thermostat). Cl ose the thermos[...]

  • Page 22

    21 Point 13 (TR) No inlet voltage (120 V). Check 5 pole conne ctor and control box. If everything is okay, first replace the connector and then the control box if problem rem ains. No outlet voltage (24 V) during ignition. Check wiring and conn ections. If everything is okay, replace the transformer. Point 14 (EV1) Valve closed during ignition. Che[...]

  • Page 23

    22 Replacement Parts TR – 120/24V Transforme r Part Number: JTRS017 Ignition Control Box Part Number: JCNT019 NP – Pressure Switch Part Number: JPRS010 Z9 – Room Thermostat Part Number: JTLT005 Z1 – Reset and Summer/Winter Switch Part Number: NTST000 Z8-Z3 – Timer and Manual - Program Mode Switch Part Number: N19800202 Z2- Hi-Lo Flame and[...]

  • Page 24

    23 RP8 : Flame Sensor Part Number:JLTT015 RP7: Spark Igniter (2 piec es) Part Number: JLTT023 S – Combustion Blower Motor Part Number: JMTR017 M1 – Overheat Thermostat Part Number: JTLT006 M2 - Fan Thermostat Part Number:J12301 018 Fan Blades (4 piec es) Part Number: VVNT003-VVNT002 M - Fan Motor Part Number: (2 Pieces) JMTR018 Williams Furnace[...]