Williams 0743511 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Williams 0743511, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Williams 0743511 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Williams 0743511. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Williams 0743511 should contain:
- informations concerning technical data of Williams 0743511
- name of the manufacturer and a year of construction of the Williams 0743511 item
- rules of operation, control and maintenance of the Williams 0743511 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Williams 0743511 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Williams 0743511, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Williams service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Williams 0743511.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Williams 0743511 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation Instructions and Owner’s Manual Direct-Vent Wall Furnace - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GA S • Open all windows. • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in y[...]

  • Page 2

    Table of Contents General Information and Technical Data Instructions to Installer …………………………………………… …………………………….………......... ........………… 1 Safety and General Warnings ……………………… ………………………………………….… ………………...………[...]

  • Page 3

    Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLE D • Due to high temperatures, the furnace should be located out of traffic and away from furniture and draperies. • Children and adults sho uld be alerted to the hazards of high surface temperatures a nd sh ould stay away to avoid burns or clothing igniti[...]

  • Page 4

    Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas Dealer ca n give you a ”Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnorm al odor, call your LP Gas Dealer. • If you are not qualified, do not light pilot lights, perform se[...]

  • Page 5

    Installation Installation should be done by a Q UALIFIED SERVICE TECHNICIAN. The furnace must be located on an o utside wall. Wall Installation Minimum clearances from comb ustible materrials: WARNING: For the installati on of this furnace, the following items must be used as a v ent air intak e system: • Unit to the top surface of carpeting, til[...]

  • Page 6

    Figure 1 1 = Fixed/Closed 2 = Openable V = Vent Terminal A = Air Supply A. Clearance above grade, verand a, porch, deck or balcony 12-inches (30 cm ) minimum. K. Clearance to a mechani cal air supply inlet 6 feet (1.8 m) minimum. (3) (3) B. Clearance to window or do or that may be open ed 12- inches (30 cm) minimum. L. Clearance (1) above paved sid[...]

  • Page 7

    5. Place the insulating sheet on the support bracket and attach t he b racket with insulation to the wall by tightening the five screws with washer. (Figure 3) Be sure the bracket is horizontal. 6. Remove the casing from the furnace bo dy, unscr ewing the two mounting screws. (Figure 3) 7. Mount the largest tube (diameter 4-inches (101.6 mm) and th[...]

  • Page 8

    8. Position the furnace on the wall inserting the inlet/outlet flue in the hole previously drilled. Make sure that t he edg es o f the support bracket perfectly match the existing hole s in th e back on the unit (Figure 5) 9. Attach the furnace to the support br acket with the two screws provid ed. Durin g this operation make all necessary adjustme[...]

  • Page 9

    3. The furnace must be isola ted from the gas supply pi ping sy stem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure s e qual to or less than 1/2 psig (3.5 kPa). Attention : If one of the ab ove procedures results in pressures in exce ss of 1/2 psig (14 ” w.c.; 3.5 kPa) o[...]

  • Page 10

    Operating Instructions Before operating the furnace, read carefully all wa rnings and safety information i n this manual. FOR YOUR S AFETY READ BE FORE OPERATING A . This ap pl ianc e ha s a pil ot w hich mus t be lighte d by me a ns of the pie z o ig nite r installe d on the unit. Do not try t o li ght the pilot by han d. B. B EFORE LIGH TIN G sme[...]

  • Page 11

    Servicing All servicing activities must be carried o ut by a qualifi ed serv ice technicial or a service a gen cy. The home owner may n ot service the furnace. The hom e owne r must read this section to be informed of the perio dic maintenance an d checks the required. All servicing (exc ept on vent system) m ust be carried out with the external ca[...]

  • Page 12

    Replacement Parts Gas Valve Part Number: JVLV023 (Natural Gas) Part Number: JVLV024 (LPG) Pilot Sparking Candle and Nozzle Part Number: J12306065 (Sparking Candle) Part Number: JGLL064 (Nozzle – Natural Gas) Part Number: J12160880 (Nozzle - LPG) Piezo Electric Button Part Number: JPZO000 Thermocouple Part Number: JTRM000D Burner Part Number: J900[...]