Wibur Curtis Company CA 90640 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Wibur Curtis Company CA 90640, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wibur Curtis Company CA 90640 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Wibur Curtis Company CA 90640. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Wibur Curtis Company CA 90640 should contain:
- informations concerning technical data of Wibur Curtis Company CA 90640
- name of the manufacturer and a year of construction of the Wibur Curtis Company CA 90640 item
- rules of operation, control and maintenance of the Wibur Curtis Company CA 90640 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wibur Curtis Company CA 90640 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wibur Curtis Company CA 90640, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wibur Curtis Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wibur Curtis Company CA 90640.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Wibur Curtis Company CA 90640 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CONTENTS Unpacking . . . . . . . . . . . Function of Gemini . . . . Setup . . . . . . . . . . . . . . . . Timer Adjustment . . . . . . Care & Maintenance . Trouble Shooting . . . . . . Parts List Gem 3 & 5 . . . . Parts List Gemini 120A . . Wiring Diagrams Gemini 120A -10 . . . . Gemini 120A -63 . . . . Warranty . . . . 1 1 1 2 2 3 5 6 9 10[...]

  • Page 2

    INSIDE FRONT COVER IS A BLANK P AGE[...]

  • Page 3

    - 1 - FUNCTION OF THE GEMINI The water in the heating tank A , is maintained at the same level at all times by a sensor called the water level probe B . This controls the water inlet valve C . When the brew switch is pushed, a brew cycle starts: The dump valve D , is opened by the brew timer E , allowing hot water to be sprayed over the ground coff[...]

  • Page 4

    ADJUSTMENT INSTRUCTIONS FOR TIMER WC-603RDS Regular cleaning and preventive maintenance is essential in keeping your Gemini Coffee Brewer looking and working like new. WARNING Do not use cleansers, liquids, bleaches, or powder that contain chlorine. These products cause corrosion and pitting on stainless steel and will void your warranty. The Gemin[...]

  • Page 5

    POSSIBLE CAUSE SOLUTION TROUBLE SHOOTING Open the water line and make sure water flows to the brewer. Turn off brewer. Disconnect wires from water inlet coil terminals and connect a power cord to the terminals. Plug cord into a 110v outlet and verify that water flow when plugged in and stops when cord is disconnected. If valve does not respond to t[...]

  • Page 6

    - 4 - PROBLEM: WATER NOT FLOWING FROM SPRAYHEAD. SOLUTION POSSIBLE CAUSE Check water level in tank. If water is not flowing into the tank, review steps 1 thru 4, previous page. Check the continuity between terminals 5B and 4B when the BREW switch is pressed. If there is no continuity, replace the switch. Make sure the timer is receiving 110 to 120 [...]

  • Page 7

    - 5 - DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION PART PART PART PART PART N N N N N º º º º º INDEX INDEX INDEX INDEX INDEX N N N N N º º º º º GEM-5 WC-1201 WC- 114R GEM 3 WC-3307 WC-5622 WC-2102 WC-2010C WC-2025 1 2 3 4 5 5A 6 7 8 SATELLITE WARMER STAND,115V . . . . . POWER CORD 6’ 18/3 BLK . . . . . . . . . . SWITCH,[...]

  • Page 8

    - 6 - GEMINI 120A Parts List B 8 2 7 2 8 B 2 5 6 3 1 6 1 4 2 1 1 4 1 9 2 0 2 4 5 7 13 1 3 9 1 0 1 1 1 2 1 7 1 5 1 5 1 8 1 8 2 3 2 2 2 6 2 9 3 0 5/23/00. 8.9 f-1903.p65.p8X 3 1[...]

  • Page 9

    Description BREW CONE, UNIVERSAL 7 1/8" BLK PLASTIC . . . . . . . . . . . . . . . . . . . . TIMER, BREW SELECTOR 120V GEM-120A . . . . . . . . . . . . . . . . . . . . . . . LEVEL CONTROL, WATER 120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPRAYHEAD, RED (.131 DIA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 10

    - 8 - WIRING DIAGRAM – GEM120A-10 VOLTAGE: 120VAC 1775 15 60 2+GND 1 WATTAGE: AMPERAGE: WIRES: HERTZ: PHASE:[...]

  • Page 11

    - 9 - WIRING DIAGRAM – GEM120A-63 VOLTAGE: 120/220VAC 1775/2100 15/10 60 3+GND 1 WATTAGE: AMPERAGE: WIRES: HERTZ: PHASE:[...]

  • Page 12

    Printed in U.S.A. 8/20/03 F-1903 Rev B W ARRANTY FOR THE LA TEST SPECIFICA TION INFORMA TION GO TO WWW .WILBURCURTIS.COM WILBUR CURTIS CO., INC. 6913 Acco St., Montebello, CA 90640-5403 USA Phone: 800/421-6150 Fax: 323-837-2410 Technical Support Phone: 800/995-0417 (M-F 5:30A - 4:00P PST) E-Mail: techsupport@wilburcurtis.com Web Site: www.wilburcur[...]