White Rodgers 2061 manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of White Rodgers 2061, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of White Rodgers 2061 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of White Rodgers 2061. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of White Rodgers 2061 should contain:
- informations concerning technical data of White Rodgers 2061
- name of the manufacturer and a year of construction of the White Rodgers 2061 item
- rules of operation, control and maintenance of the White Rodgers 2061 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of White Rodgers 2061 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of White Rodgers 2061, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the White Rodgers service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of White Rodgers 2061.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the White Rodgers 2061 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    WHITE-RODGERS DIVISION EMERSON ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398 PART NO. 37-1499B Replaces 37-1499 9516 FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Operator: Save these instructions for future use! INST ALLA TION INS[...]

  • Page 2

    2 Point “X” (locate exactly opposite 1 ⁄ 2 ” hole) Centerlines of Duct 1 ⁄ 2 ” Dia. Hole #10 Sheet Metal Screws Bearing Plate 15 ⁄ 16 ” 1 3 2 2 4 110-280 or 120-280 Thermostat 2061 Two-Wire Damper Motor INTERNAL WIRING EXTERNAL WIRING Side “A” of Motor Switch Side “B” of Motor Switch Warp Switch Heater Warp Switch Contacts ([...]

  • Page 3

    3 4. Use access-mounting plate as a template. Hold plate against duct and mark the four hole locations for attaching plate to duct. Be sure slotted hole in center of plate is over point “X” (Fig. 1) and that edge of plate is parallel with edge of duct. Then drill the four holes to take #10 sheet metal screws. 5. Cut out 4” x 8” access hole [...]

  • Page 4

    4 2 2 4 13 2 2 4 13 2 2 4 13 S81-0125 Transformer Line G H 2061 Damper Motors White-Rodgers Damper Motor Thermostats (Two-Wire) High Limit Pilot 26A00 Series Low Voltage Diaphragm Gas Valve Typical 3-Zone Gas Fired System Transformer supplies power for low voltage gas valve as well as damper motors. 2 T T 12 3 2 2 4 13 2 2 4 13 2 2 4 13 2 2 4 13 2 [...]

  • Page 5

    5 OPERA TION MANUAL OPERATION The position of the damper vane can always be determined by looking at the indicator wheel. If the word “open” is visible, the vane is open. If the word “closed” is visible, the vane is closed. Observe the following instructions in the event it is neces- sary to change the damper vanes from closed to open posit[...]

  • Page 6

    6 Furnace Plenum Connecting Duct Counter- weighted Arm Cold Air Return Air pressure bypass damper closed; all zones open and/or not operating Partially open; one or more zones closed; fan operating Open position; most zones closed; fan operating 133-0010 ZONE-AIR BYP ASS DAMPER INST ALLA TION INSTRUCTIONS DESCRIPTION This bypass damper was designed[...]