Whistler 800 WATT POWER INVERTER manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Whistler 800 WATT POWER INVERTER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Whistler 800 WATT POWER INVERTER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Whistler 800 WATT POWER INVERTER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Whistler 800 WATT POWER INVERTER should contain:
- informations concerning technical data of Whistler 800 WATT POWER INVERTER
- name of the manufacturer and a year of construction of the Whistler 800 WATT POWER INVERTER item
- rules of operation, control and maintenance of the Whistler 800 WATT POWER INVERTER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Whistler 800 WATT POWER INVERTER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Whistler 800 WATT POWER INVERTER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Whistler service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Whistler 800 WATT POWER INVERTER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Whistler 800 WATT POWER INVERTER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OWNER’S MANUAL 800 W A TT POWER INVERTER THE WHISTLER GROUP , INC CORPORA TE HEADQUARTERS 13016 N. W alton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 F AX (479) 273-2927 www .whistlergr oup.com CUSTOMER RETURN CENTER 1201 N. Dixieland Rd. Rogers, AR 72756 Consumer Relations T el (800) 531-0004 Email: info@whistlergr oup.com P/N 205563 © 2004[...]

  • Page 2

    1 If you have questions concerning the operation of this Whistler product please call consumer relations: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. Y ou may r egister your product online at www .whistlergr oup.com. If the unit is returned without a dated pr oof of pur- chase, an out of warra[...]

  • Page 3

    A Wor d About WHISTLER Inverters. Whistler inverters convert low voltage, direct curr ent (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “T echnical Operating Principles” section for more information. Depending on the model and its rated capacity , Whistler inverters draw power either [...]

  • Page 4

    INVERTER BASICS Getting Started Power equipment and appliances which operate with motors or tubes requir e an initial surge of power to get them up and running. This power surge is r eferred to as the "starting load" or "peak load." (By comparison, electrical devices such as standard light bulbs do not r equire a lar ge starting[...]

  • Page 5

    INVERTER BASICS Don’t Push It. Although your Whi stle r inverter has the capacity to provide power output (excess current) equal to appr oximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous wattage rat[...]

  • Page 6

    OPERA TION Making the Connection. This inverter is designed to connect to your 12 volt battery by the supplied #8 gauge cables. 1. Make certain that the inverter’ s rocker switch is in the OFF (O) position. 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the scr ews to make a secure connection. Do not us[...]

  • Page 7

    Important Information on Battery Chargers Using your inverter to rechar ge units designed to charge such portable equipment as power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or the charging unit. Check with the appliance manufacturer for compatibility with sine wave inverters if you’re unsur e. Altho[...]

  • Page 8

    13 ADDITIONAL FEA TURES Automatic Shut Down & Related Safety Features. Each Whistler inverter model has an unique LED Indicator warning light system which operates in conjunction with the automatic shut down feature . These indicator lights operate as follows: GREEN LED: System ready . RED LED: System overload/automatic shut down. YELLOW LED: O[...]

  • Page 9

    2. Low Battery V oltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power sour ce drops below 10.5 volts, an audible tone will be hear d. This is the low battery voltage alarm. b) The inverter will automatically shut down when the input voltage drops below 9.5 volts. This pr otects the battery from completely draining. In t[...]

  • Page 10

    17 16 OPERA TING PRINCIPLES OPERA TING PRINCIPLES assume that the measured waveform will be a pur e sine wave. Consequently , these meters will not read the RMS modified sine wave voltage correctly and, when measuring your Wh is tl er inverter output, the meters will read about 20 to 30 volts too low . T o accurately measure the output voltage of y[...]

  • Page 11

    OPERA TION SUMMAR Y 19 OPERA TION SUMMAR Y 18 • This inverter is designed to be connected to the power source with the supplied cables or with #4 wir e up to 12’ - #2 wire for longer length. When utilizing the sup- plied cables do not attempt to modify or lengthen them. • Always make certain that the power cable terminal con- nections run Neg[...]

  • Page 12

    21 20 TROUBLESHOOTING TROUBLESHOOTING PROBLEM: Low Battery Alarm On All The Time Problem Solution Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain regulation. Poor or weak battery Replace battery . condition. Inadequate power being Use lower gauge wire. delivered to the inverter or excessive voltage drop. Red LED On P[...]

  • Page 13

    SPECIFICA TIONS 23 22 TROUBLESHOOTING WHISTLER 800 WA TT INVERTER SPECIFICA TIONS Maximum Continuous Power .....................800 Watts Maximum Surge Capability (Peak Power) 1600 W atts No Load Current Draw ....................................<0.40 A W aveform ....................................Modified Sine W ave Operating Input V oltage Ran[...]

  • Page 14

    W ARRANTY IMPORT ANT : Whistler will not assume responsibility for loss or damage incurred in shipping. Ther efore, please ship your inverter insured with r eturn receipt requested. 2. Include with your unit the following information, clearly printed: • Y our name and street addr ess (for shipping via UPS), a daytime telephone number , (No P .O. [...]

  • Page 15

    W ARRANTY Service Out Of W arranty Inverters will be repair ed at “out of warranty” service rates when: • The unit’ s original warranty has expired. • Dated store receipt is not supplied. • The unit has been returned without its serial number . • The unit has been abused, modified, installed improperly , or had its housing removed. Th[...]