Westinghouse UL-ES-Contempra IV-WH05 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Westinghouse UL-ES-Contempra IV-WH05, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Westinghouse UL-ES-Contempra IV-WH05 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Westinghouse UL-ES-Contempra IV-WH05. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Westinghouse UL-ES-Contempra IV-WH05 should contain:
- informations concerning technical data of Westinghouse UL-ES-Contempra IV-WH05
- name of the manufacturer and a year of construction of the Westinghouse UL-ES-Contempra IV-WH05 item
- rules of operation, control and maintenance of the Westinghouse UL-ES-Contempra IV-WH05 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Westinghouse UL-ES-Contempra IV-WH05 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Westinghouse UL-ES-Contempra IV-WH05, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Westinghouse service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Westinghouse UL-ES-Contempra IV-WH05.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Westinghouse UL-ES-Contempra IV-WH05 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    UL-ES-Contempra IV-WH05 OWNER'S MANUAL MANUAL DEL USUARIO MR N.W . : 8 KGS G.W . : 8.7 KGS Contempra IV TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: UL_ContempraIV 1/18/05 11:53 AM Page 1[...]

  • Page 2

    2 UL-ES-Contempra IV-WH05 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After making[...]

  • Page 3

    3 UL-ES-Contempra IV-WH05 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1996), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Des[...]

  • Page 4

    4 UL-ES-Contempra IV-WH05 COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor , or change the style with just a flip of the blade. NOTE: Combo-Blade finishes vary , depending upon model. ASP AS DE DOBLE CARA Las aspas del rotor de doble cara presentan dos superficies con un acabad[...]

  • Page 5

    5 UL-ES-Contempra IV-WH05 Unpack and inspect fan carefully to be certain all contents are included. Tu rn off power at fuse box to avoid possible electrical shock. 1 Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structur[...]

  • Page 6

    6 UL-ES-Contempra IV-WH05 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers (1) from the bracket as shown above. Loosen (do not remove) the screws (2) from the bracket as shown above. Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box.[...]

  • Page 7

    7 UL-ES-Contempra IV-WH05 MOUNTING MONT AJE 5 While fan is hanging from the mounting plate, connect the wires with wire connectors (included), using the following steps for wiring options. Mientras el ventilador está colgado de la placa de montaje, conecte los cables con los conectores para cables (incluidos) usando los siguientes pasos para opcio[...]

  • Page 8

    8 UL-ES-Contempra IV-WH05 WIRING OPTIONS OPCIÓN DE CABLEADO 7 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan. Wall Control Follow diagram above to make wiring c[...]

  • Page 9

    9 UL-ES-Contempra IV-WH05 MOUNTING MONT AJE Push motor upward and attach the motor to the mounting plate by tightly securing with screws and washers provided. Empuje el motor hacia arriba y fije el motor a la placa de montaje asegurando firmemente con los tornillos y las arandelas incluidos. 8 The decorative motor housing has two mating slots (1) a[...]

  • Page 10

    10 UL-ES-Contempra IV-WH05 BLADE INST ALLA TION INST ALACIÓN DE LAS P ALET AS Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided. Tighten screws ecurely . NOTE: Some models do not utilize motor gaskets, w[...]

  • Page 11

    11 UL-ES-Contempra IV-WH05 13 14 15 Install shades to light kit by finger -tightening the screws for each shade holder as shown. Do not overtighten screws. Install light bulbs (not included). Instale las pantallas en el juego de luces apretando a mano los tornillos para cada soporte de pantalla, como se muestra. No apriete demasiado los tornillos. [...]

  • Page 12

    12 UL-ES-Contempra IV-WH05 Operation Tu rn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls directi[...]

  • Page 13

    13 UL-ES-Contempra IV-WH05 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habi[...]

  • Page 14

    14 UL-ES-Contempra IV-WH05 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart. If a problem cannot be remedied, [...]

  • Page 15

    15 UL-ES-Contempra IV-WH05 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar prob[...]

  • Page 16

    16 UL-ES-Contempra IV-WH05 UL_ContempraIV 1/18/05 11:53 AM Page 16[...]

  • Page 17

    17 UL-ES-Contempra IV-WH05 UL_ContempraIV 1/18/05 11:53 AM Page 17[...]

  • Page 18

    18 UL-ES-Contempra IV-WH05 UL_ContempraIV 1/18/05 11:53 AM Page 18[...]

  • Page 19

    19 UL-ES-Contempra IV-WH05 PA RT S LIST LIST A DE REPUESTOS # Description 1 . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . . Glass 5 . . . . . . . . . . . . . . . . . Fan Speed Switch 6 . . . . . . . . . . . . . . . . . [...]

  • Page 20

    UL-ES-Contempra IV-WH05 W estinghouse Lighting Corporation 12401 McNulty Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registered trademark of W estinghouse Electric Corporation Made in China © 2005 W estinghouse Lighting Corporation W estinghouse Lighting Corporation 1240[...]