Weil-McLain 550-100-067/0608 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Weil-McLain 550-100-067/0608, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Weil-McLain 550-100-067/0608 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Weil-McLain 550-100-067/0608. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Weil-McLain 550-100-067/0608 should contain:
- informations concerning technical data of Weil-McLain 550-100-067/0608
- name of the manufacturer and a year of construction of the Weil-McLain 550-100-067/0608 item
- rules of operation, control and maintenance of the Weil-McLain 550-100-067/0608 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Weil-McLain 550-100-067/0608 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Weil-McLain 550-100-067/0608, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Weil-McLain service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Weil-McLain 550-100-067/0608.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Weil-McLain 550-100-067/0608 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    P art number 550-100-067/0608 User’ s Information Manual Gas-fir ed water boilers – Series 3 Featuring Flexibility If the information in this manual is not followed exactly , a fire or explosion may result, causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vici[...]

  • Page 2

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 2 The following defined terms are used throughout this manual to bring attention to the presence of hazards of var ious risk levels or to important information conc erning the life of the product. Indicates pr esence of hazards that will cause [...]

  • Page 3

    P art number 550-100-067/0608 3 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual Failur e to adhere to the guidelines on this page can result in se ver e personal injury , death or substantial pr opert y damage. Boiler service and maintenance — T o a void electr ic shock, disconnect electr ical supply before performing m[...]

  • Page 4

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 4 Pr event combustion air contamination If the boiler combustion air inlet is located in any area likely to cause c ontamination, or if products w hich would contaminate the air cannot be removed, y ou must hav e the combustion air and vent re-p[...]

  • Page 5

    P art number 550-100-067/0608 5 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual Annual star tup and general maintenance Figure 1 Ser vice and maintenance schedules OWNER MAINTENANCE (see the following pages for instructions) BEGINNING OF SEASON Contact your boiler service technician to inspect, service and start up your b[...]

  • Page 6

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 6 Maintenance pr ocedures — DAIL Y Check air openings V erif y th at co mbus tio n a nd ven til ati on a ir 1. openings to the boiler room and/o r building are open and unobstructed. V erify that boiler vent disc harge and air intak e 2. are c[...]

  • Page 7

    P art number 550-100-067/0608 7 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual Maintenance pr ocedures — MONTHL Y Maintenance pr ocedures — PERIODICALL Y T est the low water cutoff (if installed) If the system is equipped w ith a low water cutoff, test the low 1. water cutoff per iodically during the heating season. [...]

  • Page 8

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 8 Maintenance pr ocedures — END OF SEASON Maintenance pr ocedures — EVER Y 6 MONTHS Follo w “TO TURN OFF GAS T O APPLIANCE” on page 9 1. of this manual. Do not drain syst em unle ss ex posur e to fr eez ing tem pera tur es 2. will occur [...]

  • Page 9

    P art number 550-100-067/0608 9 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual Operating instructions Figure 2 OPERA TING INSTRUCTIONS[...]

  • Page 10

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 10 Ultra component locations Figure 3 U-Control displa y tur ns red when boiler locks out — select MANU AL RESET to reset boiler as shown below . Figure 4 Boiler components & the U-Contr ol display[...]

  • Page 11

    P art number 550-100-067/0608 11 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual Ultra boiler’ s U-Control display Figure 5 Boiler components & the U-Contr ol display (continued)[...]

  • Page 12

    P art number 550-100-067/0608 g a s - f i r e d w a t e r b o i l e r — User ’ s Inf ormation Manual 12[...]