Viking F20533 EN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Viking F20533 EN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Viking F20533 EN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Viking F20533 EN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Viking F20533 EN should contain:
- informations concerning technical data of Viking F20533 EN
- name of the manufacturer and a year of construction of the Viking F20533 EN item
- rules of operation, control and maintenance of the Viking F20533 EN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Viking F20533 EN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Viking F20533 EN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Viking service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Viking F20533 EN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Viking F20533 EN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Viking Range Corporation 111 Front Str eet Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20533 EN (093008J) ® Viking Installation Guide Pr ofessional Fr eestanding Dual Fuel Ranges[...]

  • Page 2

    IMPORT ANT– Read and Follow! 3 2 T able of Contents W arnings & Important Safety Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _[...]

  • Page 3

    IMPORT ANT– Read and Follow! 5 4 DANGER Gas leak hazard. T o avoid risk of personal injury or death; leak testing of the appliance must be conducted according to the manufacturer ’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution. • DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. DANG[...]

  • Page 4

    Dimensions 7 Dimensions 6 Dual Fuel 30”, 36”, 48” and 60” W . Ranges 3 5 - 7 / 8 ” ( 9 1 . 1 c m ) m i n . t o 3 7 ” ( 9 4 c m ) m a x . 1 ” ( 2 . 5 c m ) 2 9 - 7 / 8 ” ( 7 5 . 9 c m ) 3 5 - 7 / 8 ” ( 9 1 . 1 c m ) 4 7 - 7 / 8 ” ( 1 2 1 . 6 c m ) 6 0 ” ( 1 5 2 . 4 c m ) Note: Unit shown with standard island trim. Note: Unit sh[...]

  • Page 5

    Specifications 9 Specifications 8 Dual Fuel 30” and 36” W . Ranges Description 30” W . Models 36” W . Models Overall width 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) Overall height T o top of side trim - 35-7/8” (91.1 cm) min 37” (94.0 cm) max L egs adjust - 1-1/8” (2.9 cm) Overall depth from r ear T o end of side panel - 24-5/16” (61.[...]

  • Page 6

    4 2 ” m i n . ( 1 0 6 . 7 c m ) 1 3 ” m a x . ( 3 3 . 0 c m ) 6 ” m i n . ( 1 5 . 2 c m ) 1 8 ” m i n . ( 4 5 . 7 c m ) 3 / 8 ” ( 0 . 9 5 c m ) 3 6 ” ( 9 1 . 4 c m ) 2 9 - 7 / 8 ” ( 7 5 . 9 c m ) Clearance Dimensions (W ood/Composite Overlay) 11 Clearance Dimensions (Pr oximity to Cabinets) 10 • This range may be installed directly [...]

  • Page 7

    13 Electrical & Gas Requir ements Flexible Connections: If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified flexible connector of at least 1/2” (1.3 cm) ID NPT (with suitable strain reliefs) in compliance with ANSI Z21.41 and Z21.69. 12 Electrical Re[...]

  • Page 8

    15 14 General Infor mation Installation READ AND FOLLOW ALL W ARNING AND CAUTION INFORMA TION WHEN INST ALLING THIS APPLIANCE. • Al l op en in gs in t he w al l be hi nd t he ap pl ia nc e and i n th e fl oo r un de r th e ap pl ia nc e mus t be s ea le d. • Do n ot o bs tr uct t he f lo w of c om bu st io n and ve nt il at ion a ir . Mo vin g,[...]

  • Page 9

    16 17 1 Remove access door . Electrical Connection (3-wir e) Note: If you have a 4-wire connection, see following section for 4-wire connection instructions. Use a 3-wire power supply cor d kit rated for 40 amps – 125/250 volts with closed loop terminals and marked for use with ranges. Do not use a GFI circuit. Wher e local codes do not permit gr[...]

  • Page 10

    19 18 1 2 Remove access door . Remove supply cord strain r elief bracket and three supply cor d mounting screws on the terminal block. Electrical Connection (4-wir e) Electrical Connection (3-wir e) (cont.) W ARNING Electrical shock hazard. T o avoid risk or electrical shock, personal injury or death; grounding product to the frame of the unit may [...]

  • Page 11

    21 20 1 2 Measure the four corners in cutout area to verify if flooring is level. For uneven or sloped floors, level unit with metal shims only , as the adjustment required may exceed the thread available in the leg. 3 4 3 /8 ” 3/8” (0 . 9 5 c m ) (0.95 cm) 3 /8 ” (0 . 9 5 c m ) Move unit into opening. Leveling/Adjustments/Alignment Electrica[...]

  • Page 12

    23 22 1 Me a sur emen t ( A ) Measurement (A) Mea su r emen t ( A ) 2 M e a s u r e m e n t ( A ) Measurement (A) + 1 / 2 ” +1/2” ( 1 . 3 c m ) (1.3 cm) M e a s u r e m e n t ( A ) + 1 / 2 ” ( 1 . 3 c m ) X X X Measure fr om floor to bottom of the anti-tip opening located on the back of range. This will be measurement (A). Lo c at e a nt i- t[...]

  • Page 13

    24 25 1 2 Reattach door to range. Open door completely . Reattach hinge trim. 3 4 Remove pins from hole in hinges. Close door . 5 If the door needs to be adjusted, loosen hinge trim screws located in step 2. Adjust the screws located between the door and kickplate using a 5/32” hex head allen wrench. After adjustment, tighten hinge trim scr ews. [...]

  • Page 14

    27 26 Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referr ed to a qualified technician. Contact Viking Range Corporation, 1-888-VIKING1 (854-4641), for the nearest service parts distributor in your area or write to: VIKING RANGE CORPORA TION PREFERRED SERVICE 1803 Hwy 82W Greenwood, M[...]

  • Page 15

    29 28 N o t e s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ [...]

  • Page 16

    31 30[...]