Vanguard Heating VDVF36PN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vanguard Heating VDVF36PN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vanguard Heating VDVF36PN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vanguard Heating VDVF36PN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vanguard Heating VDVF36PN should contain:
- informations concerning technical data of Vanguard Heating VDVF36PN
- name of the manufacturer and a year of construction of the Vanguard Heating VDVF36PN item
- rules of operation, control and maintenance of the Vanguard Heating VDVF36PN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vanguard Heating VDVF36PN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vanguard Heating VDVF36PN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vanguard Heating service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vanguard Heating VDVF36PN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vanguard Heating VDVF36PN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL DIRECT -VENT GAS FIREPLACE HEA TER ® ® VDVF36PN/PP (PENINSULA) AND VDVF36STN/STP (SEE THRU) This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only f[...]

  • Page 2

    2 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® FRONT VIEW 30 (76cm) (Opening) 23 5 / 8 (60cm) 25 (64cm) RIGHT SIDE 22 5 / 8 (57cm) 43 1 / 8 (110cm) 32 (81cm) (Opening) 1 7 / 8 (5cm) 1 1 / 4 (3cm) BA CK VIEW 39 3 / 4 (101cm) 26 3 / 8 (67cm) 3 (8cm) 1 (3cm) 2 (5cm) 3 (8cm) 22 5 / 8 (57cm) 34 3 / 4 (88cm) T OP VIEW (Left Si[...]

  • Page 3

    3 105706 OWNER’S MANUAL Models VDVF36PN/PP series are three- sided direct-vent gas fireplace heaters with a sealed combustion chamber. Models VDVF36STN/STP series are two-sided di- rect-vent gas fireplace heaters with a sealed combustion chamber. All models use a mil- livolt gas control and a millivolt ignition system. All models have a manual HI[...]

  • Page 4

    4 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® FRAMING Once the final location has been determined, observing height clearances for vent termi- nation, you may construct framing using dimensions shown in Figures 7 through 9, page 5, depending on your installation. If the appliance is to be installed directly on carpeting[...]

  • Page 5

    5 105706 OWNER’S MANUAL Figure 7 - Rough Opening for Installing Peninsula Fireplace 39 3 / 4 " (1010mm) Min. 40 1 / 2 " (1029mm) 23 5 / 8 " (600mm) 39 3 / 4 " (1010mm) Min. 40 1 / 2 " (1029mm) 23 5 / 8 " (600mm) * Figure 8 - Rough Opening for Installing Peninsula Fireplace on Platform * As required by design as long [...]

  • Page 6

    6 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inc[...]

  • Page 7

    7 105706 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life. WARNING: Seal all of[...]

  • Page 8

    8 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will tak e. Note: The location of the horizontal vent termination on the exterior w all must meet all local and national building codes and must not be easily blocked or obstructed. Snorke[...]

  • Page 9

    9 105706 OWNER’S MANUAL UP UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1/2" (190mm) V ent Opening Combustible W all V ent Opening Non-Combustible W all Figure 17 - Vent Opening Requirements Continued 3. Attach vent pipe assembly to the fire- place. Set fireplace in front of it’ s per- manent loc[...]

  • Page 10

    10 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® VENTING INST ALLA TION Continued UP Figure 21 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Figure 22 - Horizontal Termination Using Flexible Venting Horizontal V enting V ertical (V) Horizontal (H) 49.5" min. 15" max. (45 ° elbow[...]

  • Page 11

    11 105706 OWNER’S MANUAL VENTING INST ALLA TION Continued V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 4' max. 6' min. 8' max. 7' min. 10' max. 8' min. 15' max. 20' max. 20' max. Figure 23 - Horizontal Termination Configuration for Rigid Venting Usin[...]

  • Page 12

    12 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to a void obstructions, you must support the vent pipe e very 3 feet. Use wall straps for this purpose (see Figure 24). Whene ver possible, use 45 ° elbows instead of 90 ° elbo ws. T[...]

  • Page 13

    13 105706 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 26 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 27 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 28 through 31 show four different configurations for vertical [...]

  • Page 14

    14 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® V er tical V enting V = 30' max. Figure 31 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° E lbows V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min.[...]

  • Page 15

    15 105706 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the inp[...]

  • Page 16

    16 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® Figure 33 - Wall Switch Wiring Diagram OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL (GHRC(T) SERIES) INSTALLATION Note: If using an optional wireless hand- held remote control, the wall switch is no longer operational. Figure 35 - Installing Remote Receiver (Shown from Rear [...]

  • Page 17

    17 105706 OWNER’S MANUAL INST ALLA TION Continued Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit 1. Remov e battery cov er on back of re- mote control unit. 2. Attach terminal wires to the battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote con- trol unit. Figure 37 - Installin[...]

  • Page 18

    18 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® INST ALLA TION Continued INSTALLING LOG SET Before proceeding, make sure the gas con- trol valve is in the “OFF” position. Logs have been packaged separately to prevent damage to glass or refractory. 1. Remove top and bottom louvers b y si- multaneously pulling both top[...]

  • Page 19

    19 105706 OWNER’S MANUAL INST ALLA TION Continued WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier. BURNER REMOVAL CAUTION: Before proceed- ing, make[...]

  • Page 20

    20 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® OPERA TING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, the appliance may emit a slight odor for about 16 - 24 hours. This is normal and is due to the “curing” of the logs and the “burn-in” of internal paints and lubricants used in the manufa[...]

  • Page 21

    21 105706 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. T urn off the w all switch. 2. T urn off all electric po wer to the ap- pliance if service is to be perf ormed. 3. Remove contr ol access panel. 4. Push in gas control knob slightly and turn clockwise to “OFF”. Do not f orce. 5. Replace control access panel. Figure 51 - Pilot Thermocoup[...]

  • Page 22

    22 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® 1. After lighting, let pilot flame burn f or about one minute. T urn contr ol knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMO TE position. Note: The bur n- ers may light if hand-held remote ON button was [...]

  • Page 23

    23 105706 OWNER’S MANUAL Thermocouple Incoming Main Gas Supply Piezo Ignitor Control V alve V ariable Speed Control * Remote Control Electrical Rating: 120v , 60Hz, 0.7A Blower * Use Extension Cord (Included With Kit) Pilot TH TP TPTH Thermopile Piezo Ignitor Do Not Connect T o 120V N.O .SW (W all Switch Supplied) Pilot Gas Line Wirew ay GND BLK [...]

  • Page 24

    24 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® TROUBLESHOOTING OBSERVED PROBLEM Pilot will not light No gas to burner, although wall switch and valve are set to the ON position Frequent pilot outage Burner goes off after a short time POSSIBLE CAUSE 1. No gas supply , or shut-off v alv e is OFF 2. Air in gas line 3. Cons[...]

  • Page 25

    25 105706 OWNER’S MANUAL www.desatech.com TROUBLESHOOTING Continued POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor cable pinched or wet 3. Piezo ignitor nut is loose 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1. Gas supply turned of f or manual sh[...]

  • Page 26

    26 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise j[...]

  • Page 27

    27 105706 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re[...]

  • Page 28

    28 105706 DIRECT -VENT GAS FIREPLACE HEA TER VDVF36P and VDVF36ST Series ® ACCESSORIES RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT - GHRC For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control. LOG SET - 105891-01 (27237) Log Piece A - 105896-01 (27238) Log Piece B - 105895-01 (27239) Log Piece C[...]

  • Page 29

    29 105706 OWNER’S MANUAL GAS CONTROL VALVE Natural - 105882-01 (25699) Propane/LP - 105882-02 (25700) If in need of replacing, have a qualified technician replace it. END GLASS ASSEMBLY (Peninsula Only) 105899-01 (25709) (Ceramic) ORIFICE Natural - 105890-01 (27224) Propane/LP - 105890-02 (25238) REFRACTORY PIECES Front (Bottom) 105886-01 (25854)[...]

  • Page 30

    LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the[...]