United States Stove EC95 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of United States Stove EC95, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of United States Stove EC95 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of United States Stove EC95. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of United States Stove EC95 should contain:
- informations concerning technical data of United States Stove EC95
- name of the manufacturer and a year of construction of the United States Stove EC95 item
- rules of operation, control and maintenance of the United States Stove EC95 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of United States Stove EC95 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of United States Stove EC95, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the United States Stove service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of United States Stove EC95.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the United States Stove EC95 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EC95 1 Installation, Operation and Maintenance Instructions TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ................................................................................................................................................ 1 BUILDING CODES AND SAFETY STANDARDS ............................................................[...]

  • Page 2

    2 EC95 SELECTING A LOCATION FOR THE HEATER When selecting a location for the heater, be sure attention is given to the following considerations: 1. If the heater is to be vented into a Listed High Temperature Type HT Factory-Built Residential Type And Building Heating Appliance Chimney, review the installation instructions for the chimney to comply[...]

  • Page 3

    EC95 3 FIGURE 3 - MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 - MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW[...]

  • Page 4

    4 EC95 FLOOR PROTECTION PIPE ANGLE UP HORIZONTAL TO HEATER FIGURE 6 - RISE OF HORIZONTAL CHIMNEY CONNECTOR PIPE TO CHIMNEY RISE: 1/4" FOR EACH FOOT OF CONNECTOR LENGTH FIGURE 5 - FLOOR PROTECTION This heater has been designed to prevent excessive temperatures on the floor beneath the heater. It is important, however, tha t a combustible floor [...]

  • Page 5

    EC95 5 There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A fireclay liner (ASTM C315 or equivalent) having a 5/8"[...]

  • Page 6

    6 EC95 MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. CHIMNEY LENGTH FLUSH WITH INSIDE OF FLUE NONSOLUBLE REFACTORY CEMENT MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 CHIMNEY CONNECTOR TO HEATER MINIMUM CLEARANCE 9 IN. ALL AROUND SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS) CHIMNEY FLUE SOLID INSULATED, LISTED [...]

  • Page 7

    EC95 7 SHEET STEEL SUPPORTS CHIMNEY SECTION CHIMNEY CONNECTOR AIR SPACE 2 IN. TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL. PART C FIGURE 5 PART D FIGURE 5 MINIMUM CLEARANCE 2 IN. ALL AROUND CHIMNEY THIMBLE 1 IN. AIR SPACE TO CHIMNEY LENGTH MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS)[...]

  • Page 8

    8 EC95 FIGURE 8 - CONNECTING HEATER’S CHIMNEY CONNECTOR TO MASONRY CHIMNEY WHEN CHIMNEY CON- NECTOR DOES NOT HAVE TO PASS THROUGH A COMBUSTIBLE WALL HEA TER INSPECTION Before installing the heater, inspect the heater for external damage and missing parts. Check the gaskets around the doors to assure that they are still in place. Also check inside[...]

  • Page 9

    EC95 9 Two common types of clearance reductions systems use sheet metal with a thickness of 28 gauge (galvanized steel, aluminum, copper) or a 3-1/2 inch (4 inch thick nominal) thick masonry wall. Either of these materials must be spaced out 1 inch from th e combustible surfaces. With sheet metal, noncombustible spacers are used to maintain the 1 i[...]

  • Page 10

    10 EC95 FIGURE 9 - HEATER OPERATION INFORMATION HEATER OPERATION IMPORTANT: DO NOT USE THE HEATER UNTIL A PROFESSIONAL INSPECTION HAS BEEN MADE OF THE ENTIRE INSTALLATION BY YOUR LOCAL FIRE DEPARTMENT, FIRE MARSHAL OR BUILDING CODE INSPEC- TOR. INSTALL A SMOKE DETECTOR ON EACH FLOOR OF YOUR HOME; IN CASE OF ACCIDENTAL FIRE FROM ANY CAUSE IT CAN PRO[...]

  • Page 11

    EC95 11 FIGURE 10 - OPENING AND CLOSING FUEL FEED DOOR FIRETENDING Firetending is the occasional poking or stirring of the burning fuel bed to ensure airflow through the fire and adding new wood as needed. With experience, you should determine how often fire tending is required to maintain the desired heat output of the heater. To ensure safe and s[...]

  • Page 12

    12 EC95 The second factor in determining heat output is its density or weight per cord. With equal seasoning and dryness, heavier, denser wood has more heating value per cord. For example, hickory is denser wood than pine, so a cord of hickory will give more heat than a cord of pine. For longer and safer heater life, never use manufactured composit[...]

  • Page 13

    EC95 13 Tap each chimney connector pipe with a small hammer or poke with a screwdriver to reveal where the metal is getting thin due to corrosion on the inside. Elbows usually give out first. Replace as necessary. YOU SHOULD ALWAYS INSPECT AND CLEAN THE HEATER’S VENTING SYSTEM BEFORE EACH HEATING SEASON. TROUBLESHOOTING Problems can arise during [...]

  • Page 14

    14 EC95 FIGURE 11 - CHIMNEY HEIGHT REQUIREMENTS 6. Check the entire system for obstructions that could be causing resistance to the flow of smoke and gases up the chimney. 7. Check the size of the chimney flue liner. If the chimney flue liner’s inside dimension is smaller that 6 inches round or 8 inches square, it will be too restrictive to the f[...]

  • Page 15

    EC95 15 2. Symptom: Fire rate too high when thermostat closed: Check for: a. Feed door or ash door not securely closed. b. Feed door or ash door gasket worn excessively. 3. Symptom: Smoke smell in living space: Check for: a. Items a through f of NO. 1 above. FINAL CHECKLIST OF DO’S AND DON’TS DO’S 1. Do read and follow the installation, opera[...]

  • Page 16

    16 EC95 DONT’S 1. Don’t dry clothing or other articles on or near the heater. 2. Don’t store or place flammable liquids, gases, or other pressurized containers near the heater. 3. Don’t use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or intensify a fire. Using these and other similar m[...]

  • Page 17

    EC95 17 FIGURE 12 ILLUSTRATION OF REPAIR PARTS. SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS. 47 58[...]

  • Page 18

    18 EC95 SEE FIGURE 12 FOR ILLUSTRATION OF PARTS CUSTOMER NOTE: IN ADDI- TION TO THE REPAIR PARTS, KITS INCLUDE ANY RE- PLACEMENT FASTENERS WHICH WILL MOST LIKELY BE NEEDED TO INSTALL THE REPAIR PART. SAVE THIS MANUAL FOR FUTURE REFERENCE K E Y QTY. EC95 NO. PART NAME Per Unit PART NO. 1 Inner Unit Assy. Ptd. 1 69228B 2 Gasket 1 88094 3 Collar Flue [...]

  • Page 19

    EC95 19 INSTRUCTION MANUAL ADDENDUM This addendum is a supplement to the Installation, Operation, and Maintenance Instruction Manual for this appliance. Do not neglect to read all instructions thoroughly. ATTENTION: Installers of Fireplaces, Fireplace Stoves, Room Heaters, and Fireplace Inserts. SUBJECT: Determining Equivalent Materials for Use as [...]

  • Page 20

    20 EC95[...]