Unitary products group D1EB036 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Unitary products group D1EB036, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Unitary products group D1EB036 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Unitary products group D1EB036. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Unitary products group D1EB036 should contain:
- informations concerning technical data of Unitary products group D1EB036
- name of the manufacturer and a year of construction of the Unitary products group D1EB036 item
- rules of operation, control and maintenance of the Unitary products group D1EB036 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Unitary products group D1EB036 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Unitary products group D1EB036, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Unitary products group service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Unitary products group D1EB036.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Unitary products group D1EB036 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION MANUAL - 50 HZ CAUTION: READ ALL SAFETY GUIDES BEFORE YOU BEGIN TO INST ALL YOUR UNIT . SA VE THIS MANUAL CHAMPION ® SERIES SINGLE P ACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED MODELS: D1EB036, 048 DIRECT DRIVE D1EB060 BEL T DRIVE (WORLD 50 HZ) 173858-YIM-A-0306 CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 2

    173858-YIM-A-0306 2 Unitary Products Group T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REPLACEMENT PARTS . . . . . . . .[...]

  • Page 3

    173858-YIM-A-0306 Unitary Products Group 3 GENERAL Model D1EB units are factory assembled cooling only air con- ditioners designed for outdoor installation on a rooftop or a slab. The units are completely assembled on rigid, but easily removable base rails. All p iping, refri gerant ch arge, a nd elec- trical wiring is factory installed and tested.[...]

  • Page 4

    173858-YIM-A-0306 4 Unitary Products Group should meet local codes an d unit weight. Do not tie the slab to the build ing foundation. 4. For roof top installation, be sure the structure will support the weight of the unit plus a ny field installed components. Unit must be installed on a le vel roof curb or appropriate angle iron frame providing ade[...]

  • Page 5

    173858-YIM-A-0306 Unitary Products Group 5 Duct work should be designed and size d according to the methods of the Air Condition ing Contractors of America (ACCA), as set forth in their Manual D. A closed return duct system sha ll be used. This shall not pre- clude use of econo mizers or ve ntilation air intake. Flexibl e joints may be used in the [...]

  • Page 6

    173858-YIM-A-0306 6 Unitary Products Group T ABLE 3: PHYSICAL DA T A COMPONENT MODELS DEB036 DEB048 DEB060 NOMINAL TONNAGE 3.0 4.0 5.0 COOLING PERFORMANCE RA TING T1 T2 T2 T1 T2 T3 T 1 T2 T3 Indoor DB/WB °C 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 Outdoor DB/WB °C 35 / 24 46 / 24 27 / 19 35 / 24 46 / 24 27 / 19 35 /[...]

  • Page 7

    173858-YIM-A-0306 Unitary Products Group 7 POWER AND CONTROL WIRING Field wiring to the unit must conform to provision s of the cur- rent N.E.C. ANSI/NFP A No. 70 or C.E.C. and/or local ordi- nances. The unit must be electric ally grounded in accordance with local codes or , i n their absence, with th e N.E.C./C.E.C. V oltage tolerances which must [...]

  • Page 8

    173858-YIM-A-0306 8 Unitary Products Group CHECKING SUPPLY AIR CFM T o check the supply air CF M after the initial balancing has been completed: 1. Remove the two ¼ inch dot plugs in the duct panel. 2. Insert at least 8 i nches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. [...]

  • Page 9

    173858-YIM-A-0306 Unitary Products Group 9 T ABLE 5: ADDITIONA L ST A TIC RESIST ANCE Size (T ons) Model Airflow m 3 /s (cfm) Wet Indoor Coil Pa (in.wc) Economizer 1 Pa (in.wc) Filter / Frame Kit Pa (in.wc) 036 (3.0) DEB 0.42 (900) 0.47 (1000) 0.52 (1 100) 0.57 (1200) 0.61 (1300) 0.66 (1400) 0.71 (1500) 12.45 (0.05) 14.95 (0.06) 17.44 (0.07) 17.44 [...]

  • Page 10

    173858-YIM-A-0306 10 Unitary Products Group T ABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL) OUT DOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,300 CFM INDOOR WB T E MPERA TURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.1 21.6 22.1 22.7 23.2 23.8 24.3 25.3 26.4 26.9 27.4 70 19.5 20.0 20.6 21.1 21.7 22.2 22.8 24.0 25.1 25[...]

  • Page 11

    173858-YIM-A-0306 Unitary Products Group 11 T ABLE 8: D1EB048 SUPERHEAT CHARGING (IMPERIAL) OUTDOO R TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,800 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 19.9 21.0 22.1 23.3 24.4 25.6 26.7 28.0 29.3 30.0 30.7 70 16.5 17.9 19.2 20.6 22.0 23.4 24.8 26.3 27.8 28.6[...]

  • Page 12

    173858-YIM-A-0306 12 Unitary Products Group T ABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 2,000 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.9 23.8 25.7 27 .6 29.4 31.3 33.2 34.2 35.1 35.6 36.1 70 16.0 18.4 20.7 23 .0 25.3 27.6 30.0 31.3 32.7 33[...]

  • Page 13

    173858-YIM-A-0306 Unitary Products Group 13 FIGURE 5 - UNIT DIMENSIONS +,*+92/ 7$*(&211 ´',$.12&.287 +,*+92/ 7$*(&211 ´',$.12&.287 /2:92/ 7$*(&211 ´',$.12&.287 6,'(?[...]

  • Page 14

    173858-YIM-A-0306 14 Unitary Products Group SEQUENCE OF OPERA TION COOLING The following sequence s of operation are based on using a standard single-stage cooling thermostat. WITH POWER TO UNIT AND THERMOST A T IN COOLING MODE 1. If the fan switch on the thermo stat is in the “ON” position, the 24 volts at “G” will e nergize the “K1"[...]

  • Page 15

    173858-YIM-A-0306 Unitary Products Group 15 FIGURE 3 - TYPICAL WIRING DIAGRA M 3 & 4 TON (380/415-3-50 POWER SUPPLY)[...]

  • Page 16

    173858-YIM-A-0306 16 Unitary Products Group FIGURE 4 - TYPICAL WIRING DIAGRAM 5 TON (380/415-3-50 POWER SUPPLY)[...]

  • Page 17

    173858-YIM-A-0306 Unitary Products Group 17 FIGURE 5 - TYPICAL WIRING DIAGRAM LEGEN D FIGURE 6 - TYPICAL WIRING DIAGRAM NOTE S &% &2035 ) )= +3 . . /3 0 0 0 5& 5& 63 63 63 63 7 &,5&8,7%5($.(59 $03 &2035(6625 )86(96(&[...]

  • Page 18

    173858-YIM-A-0306 18 Unitary Products Group[...]

  • Page 19

    173858-YIM-A-0306 Unitary Products Group 19[...]

  • Page 20

    Subject to change without notice. Print ed in U.S.A. 173858-YIM-A-0306 Copyright © 2006 by Unitary Products Gro up. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product s Y ork OK Group Drive 73069[...]