Twin-Star International 33EB304GRS manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Twin-Star International 33EB304GRS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Twin-Star International 33EB304GRS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Twin-Star International 33EB304GRS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Twin-Star International 33EB304GRS should contain:
- informations concerning technical data of Twin-Star International 33EB304GRS
- name of the manufacturer and a year of construction of the Twin-Star International 33EB304GRS item
- rules of operation, control and maintenance of the Twin-Star International 33EB304GRS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Twin-Star International 33EB304GRS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Twin-Star International 33EB304GRS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Twin-Star International service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Twin-Star International 33EB304GRS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Twin-Star International 33EB304GRS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    E-1 MODEL NUMBERS: 33EB304GRS 39EB364GRS BUIL T IN ELECTRIC FIREPLACE INST ALLA TION GUIDE CONSUMER SAFETY INFORMA TION PLEASE READ THIS MANUAL BEFORE INST ALLING THIS APPLIANCE W ARNING IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED, AN ELECTRIC SHOCK OR FIRE MA Y RESUL T CAUSING PROPER TY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. DO NOT STORE [...]

  • Page 2

    LISTINGS AND CODE APPRO V ALS THE BUILDERS BO X SERIES HAS BEEN TESTED AND APPROVED IN A CCORD ANCE WITH THE CSA xxxxxxx No. xxxxxxx ST AND ARDS F OR FIXED AND LOCA TION DEDICA TED ELECTRIC ROOM HEA TERS. MODEL SPECIFICA TIONS MODEL NUMBER DESCRIPTION VOL T AGE RA TED PO WER W A TTS REMOTE CONTROL AMPS 33EB304AAS 33” ST AND ARD 120/208/240 1440/2[...]

  • Page 3

    F raming Specications: Figure 1 This replace is a zero clearance design. No combustibles can be placed on the t op sur face of the replace. Combustibles ma y be installed t o the edge of the unit. F or 1 20 volt installations use two conduct or , non-metallic sheath cable with ground wire (3 wires to tal) for the incoming power supply on ?[...]

  • Page 4

    V olt age Selector Switch: Figure 2 The voltage select or switch is located inside the exhaust panel on the t op lef t hand corner . Carefully insert a at headed screw - driver inside the e xhaust panel through the hole in the mesh t o c hange the switch from 2 40 volts (230 position) t o 1 20 volts (115 position). The unit ships with the switch[...]

  • Page 5

    There are two mounting anges locat ed on each side of the replace inser t. Bend tabs accordingly and mount t o framing using suitable hardware. Mounting Flange Location: Figure 3 MOUNTIN G FLANGE S W all and Mounting Flange: Figure 4 Mounting T olerances - T op View: Figure 5 STUD WOOD OR MET AL MOUNTING FLANGE DR YW ALL / SHEE TROC K CERAM I[...]

  • Page 6

    JUNCTION BOX 1 . Locate the v oltage selector switch inside the exhaust panel on the t op lef t hand corner of the unit. (see gure 2 on page 3) 2. Conrm the switch is set t o 1 20 volt conguration ( 115 volt is print ed on switch). 3. Loosen the screw securing the junction box co ver and remov e the cover . 4. R emove the knockouts (if nec[...]

  • Page 7

    N - WHITE WIRE L2 - RED WIRE L1- BLACK WIRE G- GREEN WIRE N- WHITE WIRE L1 - BLACK WIRE G - GREEN WIRE FIREPLACE -JUNCTION BO X 120 VOL T POWER SUPPL Y BREAKER P ANEL N L2 L1 G N L2 L1 G Wire Connection Diagram: Figure 7 E-7[...]

  • Page 8

    JUNCTION BOX 1 . Locate the voltage select or switch inside the exhaust panel on the t op lef t hand corner of the unit. (see gure 2 on page 3) 2. Conrm the switch is set t o 2 40 volt conguration (230 volt is print ed on switch). 3. Loosen the screw securing the junction box co ver and remov e the cover . 4. R emove the knockouts (if nece[...]

  • Page 9

    N - WHITE WIRE L2 - RED WIRE L1- BLACK WIRE G- GREEN WIRE N- WHITE WIRE L1 - BLACK WIRE G - GREEN WIRE FIREPLACE -JUNCTION BO X 240 VOL T POWER SUPPL Y BREAKER P ANEL L2 - RED WIRE N L2 L1 G N L2 L1 G Wire Connection Diagram: Figure 9 E-9[...]

  • Page 10

    JUNCTION BOX 1 . Loosen the screw securing the junction box and remo ve the cov er . 2. R emove the knockouts (if necessary) or use the pro vided cable clamp. 3. Pull out the three wires mark ed T1 , T2, and TG. (red, red, and green) 4. R emove the wire connect or and separate the wires mark ed T1 & T2. 5. Connect the (red) T1 wire from the uni[...]

  • Page 11

    T 2 - RED WIRE FIREPLACE -JUNCTION BO X ME CHAN ICA L LI NE V OLT AGE TH ERMO STA T WA LL M OUN TED T 1 - RED WIRE T G - GREEN WIRE T 2 T 1 T G 2 CONDUCT OR WIRE FROM W ALL THERMOST A T T 2 T 1 T G B L A C K W I R E W H I T E W I R E G R O U N D W I R E R E D W I R E B L A C K W I R E Wire Connection Diagram: Figure 11 E-11[...]

  • Page 12

    Section 8: Wiring Schematic - Bottom Section & PCB E-12[...]

  • Page 13

    Section 9: Wiring Schematic - Heater E-13[...]

  • Page 14

    A Division of T win-Star Int ernational, Inc. 115 S.E. 4th Av enue • Delray Beach, Florida 33483 Phone: 56 1-330-3201 • F ax: 561-330-3205 www .classicame.com E-14[...]