Tripp Lite SU80K3/3PM manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite SU80K3/3PM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite SU80K3/3PM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite SU80K3/3PM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Tripp Lite SU80K3/3PM should contain:
- informations concerning technical data of Tripp Lite SU80K3/3PM
- name of the manufacturer and a year of construction of the Tripp Lite SU80K3/3PM item
- rules of operation, control and maintenance of the Tripp Lite SU80K3/3PM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite SU80K3/3PM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite SU80K3/3PM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite SU80K3/3PM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite SU80K3/3PM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Owner's Man ual W ARRANTY REGISTRA TION: register online toda y for a chance to win a FREE T ripp Lite product— www .tr ipplite.com/w arranty Smar tOnline ™ 3-Phase (50kV A & Abo ve) Intelligent T rue On-Line UPS Systems Input/Output: 3Ø, 4 Wire (plus gr ound), wy e • SU50K3/3PM & SU80K3/3PM Models: ................277/480V A C [...]

  • Page 2

    2 Impor tant Safety W arnings SA VE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the installation and maintenance of all T ripp Lite SmartOnline 3-Phase UPS Systems (50kV A and above) and their batteries. All UPS connection and main tenance must be performed by qualified service personn[...]

  • Page 3

    3 Impor tant Safety W arnings (continued) • Connect only T ripp Lite battery modules to your UPS's external battery hardware terminals. • Do not operate your UPS without batteries. • Fuses should be replaced only by factory authorized personnel. Blown fuses should be replaced only with fuses of the same number and type. • Potentially l[...]

  • Page 4

    4 P ower Module Features There are two separate UPS system modules: a power module and a 348V DC battery module. Familiarize yourself with the location and function of the features on each module before installing and operating your UPS system. The power module is described below . The 348V DC battery module is described in its owner's manual,[...]

  • Page 5

    Installation Follow all warnings listed in the Safety section prior to installation. The following checklist provides a general guide rather than a complete outline of procedures. Installation Checklist K The floor area where the UPS will be installed has enough supporting strength. See “Floor W eight Loading T able” on page 6. K The entrances [...]

  • Page 6

    6 Electrical Connection • Connection Chec klist • Recommended Cable Sizes • T erminal Wiring Diagrams • P arallel Wiring Diagrams Follow all warnings listed in the Safety section prior to hardwire terminal connection. The following checklist provides a general guide rather than a complete outline of procedures. Connection Checklist K T urn [...]

  • Page 7

    7 Electrical Connection (continued) T erminal Wiring Diagrams The following wiring diagrams are organized according to V A. W ithin each V A grouping, there is a “single loop” connection option (where only one input source is used) and a “double loop” connection option (where two input sources are used). SU50K3/3PM & SU50K3/3INTPM Model[...]

  • Page 8

    8 Single UPS Operation The diagrams and procedures in this section apply to a single UPS Power Module connected to a single equipment load. Note: all diagrams assume the presence of two separate AC sources supplying two separate inputs: a mains source supplying rectifier input and a reserve s ource supplying reserve input. If your application only [...]

  • Page 9

    9 Single UPS Operation (continued) Reserve AC Input Supply Mode In this mode, the power module's inverter has encountered one of several abnormal operating conditions including overtemperature, continual overload, shorted output or depleted battery power . The power module automatically shuts down the inverter to prevent damage. In order to by[...]

  • Page 10

    10 Single UPS Operation (continued) After following all warnings listed in the Safety section and precautions listed above, start-up UPS according to the following procedure: S tep 1. T urn on (close) the “RESER VE INPUT” Breaker . The LCD Screen will display “Bypass Mode”. S tep 2. T urn on (close) the “RECTIFIER INPUT” Breaker and wai[...]

  • Page 11

    11 Multiple UPS Operation (P arallel) The diagrams and procedures in this section apply to a parallel configuration where multiple UPS Power Modules (up to eight) are connected to a single equipment load. A parallel configuration provides fail-safe redundancy , assuring that the load is constantly supported even if one or more UPS Systems fail or a[...]

  • Page 12

    12 Multiple UPS Operation (P arallel) (continued) Back-Up Mode In this mode, utility AC input power has failed. Since the UPS Systems operate continuously on-line, their connected battery mo dules instantly (with zero transfer time) supply DC power to their inverters. Their inverters, in turn, transform DC power into clean, stable A C output power [...]

  • Page 13

    13 Multiple UPS Operation (P arallel) (continued) Maintenance Bypass Mode In this mode, the Manual Maintenance Procedure (On Bypass) has been performed in order to pass-through filtered AC input power (from a reserve AC input source) to connected equipment loads while allowing maintenance on the UPS power module. (Note: since the power module'[...]

  • Page 14

    14 Multiple UPS Operation (P arallel) (continued) Common Battery In this configuration, a single bank of battery modules is shared by multiple UPS power modules. This not only reduces installation costs, but saves floor space. Note: when using the LCD Screen to set battery charging, divide the char ging task equally among all UPS power modu les. Fo[...]

  • Page 15

    15 Multiple UPS Operation (P arallel) (continued) Shutdown Pr ocedure This procedure removes power from and shuts down the UPS power modules. W ARNING! When shutting down individual UPS power modules in a parallel configuration, the user must ensur e that the UPS power modules within the configuration that remain ON can collectively power the equip[...]

  • Page 16

    16 LCD Displa y Navigation The LCD Screen displays a wide variety of operational conditions as well as provides managers with the ability to set operational parameters and view event logs. The LCD Screen will display a block diagram of the current operating mode. The Normal Mode is provided as an example. P ASSWORD NOTE: navigating select screens w[...]

  • Page 17

    17 LCD Displa y Navigation (continued) “P arameter Setting” Sub-Menu This sub-menu allows you to set UPS operational parameters. A password is required to access this sub-menu. Note: The default pa ssword is 0 0 0 0. T o change the password, select the “Password Setting” screen in this sub-menu. Also Note: SU50K3/3PM and SU80K3/3PM models f[...]

  • Page 18

    18 LCD Displa y Navigation (continued) “System Control” Sub-Menu This sub-menu allows you to directly control UPS operation. A password is required to access this sub-menu. Note: The default password is 0 0 0 0. T o change the password, select the “Password Setting” screen in the “Parameter Setting” sub-menu. A A B B E E F F C C D D Cho[...]

  • Page 19

    19 LCD Displa y Navigation (continued) “Other Information” Sub-Menu This sub-menu allows managers to view a variety of additional UPS System information. UPS Status Code Note: a UPS S tatus Code is displayed in the upper -right corner of the screen in the following display . Use the chart below to determine what the UPS S tatus Code indicates. [...]

  • Page 20

    20 Comm unications Dry-Contacts Remote Emergency P ower Off (EPO) This feature is only for those applications that require connection to a facility's Emergency Power Of f (EPO) circuit. When the power module is connected to this circuit, it enables emergency shutdown of the output.[...]

  • Page 21

    21 Comm unications (continued) RS-232 P or t/Ethernet P or t/SNMP Card Slot The RS-232 port connects your UPS via an RS-232 cable to a workstation or server equipped with T ripp Lite power management soft ware. The RS-232 port uses RS-232 communications to report UPS status and power conditions. Contact T ripp Lite Customer Support for infor mation[...]

  • Page 22

    22 Comm unications (continued) RS-485 P or ts These ports connect multiple UPS power modules in a parallel connection. UPS P arallel Communication P or ts These ports allow multiple UPS power modules to communicate while in a parallel configuration. TX485+ TX485- RX485+ RX485- RS-485 P ort RS-485 P ort TERMIN AL RESISTOR FOR RS-485 Normally Closed [...]

  • Page 23

    23 Service Y our SmartOnline 3-Phase UPS System is covered by the limited warranty described below . Extended warranty (2-, 3- and 4-year) a nd start-up service programs are available. For more information, call T ripp Lite Customer Service at (773) 869-1234. W arranty & W arranty Registration LIMITED W ARRANTY Seller warrants this product, if [...]

  • Page 24

    1111 W . 35th Street • Chicago , IL 60609 USA (773) 869-1234 • www .tr ipplite.com 200503068 93-2439[...]