Tripp Lite 120/208V manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Tripp Lite 120/208V, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tripp Lite 120/208V one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Tripp Lite 120/208V. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Tripp Lite 120/208V should contain:
- informations concerning technical data of Tripp Lite 120/208V
- name of the manufacturer and a year of construction of the Tripp Lite 120/208V item
- rules of operation, control and maintenance of the Tripp Lite 120/208V item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tripp Lite 120/208V alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tripp Lite 120/208V, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tripp Lite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tripp Lite 120/208V.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Tripp Lite 120/208V item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1. Important Safety W arnings 2 2. Control P anels 3 2.1 Front P anel 3 2.2 Battery Access Panel (Co ver Removed) 4 2.3 Rear Panel 5 3. Installation 6 3.1 UPS Location 6 3.2 Mounting Bracket Installation 6 3.3 Grounding Connection 6 3.4 UPS Input And Output Hard wire Connection 6 3.5 Initial Battery Charging 7 4. Operation (Normal Conditions) 7 4.1[...]

  • Page 2

    2 SA VE THESE INSTR UCTIONS. This manual contains important instructions and warnings that should be follo wed during the installation and maintenance of all T ripp Lite SmartOnline 3-Phase 20kV A and 30kV A UPS Systems. UPS Location Warnings • Installyour UPS in acontrolled en vironment. • Installyour UPS indoo[...]

  • Page 3

    2. Control P anels 3 Note: F amiliarize yourself with the location and function of the features on your UPS system befor e installing and operating it. “ON” Button: 1. This buttonturns theUPS System's in verter ON. “OFF” Button: 2. Thisbutton turnsthe UPS System'sinv erter OFF . Note: I[...]

  • Page 4

    4 1 2 3 4 5 6 7 Individual models may vary slightly from diagram. 2.2 Battery Access P anel (Cover Removed) 2. Control P anels ( continued ) Internal Battery Packs: 1. Thesesupply backup runtime toconnected equipment. Eachpack consists oftwo strings (onepositiveand onenegativ e). Thenumber[...]

  • Page 5

    Individual models may vary slightly from diagram. 5 Manual Bypass Switch: 1. This dialis used toput the UPS in“BYP ASS” mode, whichmust be donebefore performing anymaintenance on theUPS withthe connected load supported.(See section 5, Operation (Special[...]

  • Page 6

    6 Mov e your UPS over short distances using its wheels. Note: The wheels ar e not designed to pro vide long-term support for the UPS system after f inal installation. Mounting brack et installation is requir ed. D ANGER! RISK OF PRODUCT D AMA GE AND SERIOUS PERSONAL INJUR Y The UPS System's wheels are not designed to pr ovide long-term support[...]

  • Page 7

    7 WIRING CONNECTION Connectyour wiring to theinput and outputterminal blocks locatedon the rear panelof your UPS(see figurebelow). CA UTION! Qualified personnel should follo w all procedures prescribed by N.E.C. and other local codes for hardwiring devices to a utility source. Ensure[...]

  • Page 8

    8 Momentarilypress the “SELECT” buttononthe front panelto browsethrough differentpowerreadings onthe LCD Display . BYP ASS OUTPUT R: XXXV R: XXX.XV S: XXXV S: XXX.XV T: XXXV T: XXX.XV (Bypass&Output Vo ltage) OUTPUT LO AD R: XXX% XXX.XA S: XXX% XXX.XA T: XXX% XXX.XA (Output?[...]

  • Page 9

    9 Condition LCD Display Message Overload Shutdown ONBYP ASS O VERLO AD 150% SHUTDO WN... VERSION: XXXXXXX UPS Output Short Circuit ONBYP ASS SHOR T CIRCUIT! SHUTDO WN... VERSION: XXXXXXX Overtemperature ONBYP ASS HIGHTEMP! SHUTDO WN... VERSION: XXXXXXX DCBUS Overv oltage ON BYP ASS DCBUS O.V .P .! SHUTDO WN... VERSION:[...]

  • Page 10

    3 V + - 10 Thisfemale DB9 port connectsyour UPS viaan RS-232 cableto a workstationor serverequipped withTrippLite software.Theport uses RS-232 communicationsto report UPS statusand powerconditions. Usingthis port,TrippLite softwareca[...]

  • Page 11

    X 1 2 3 4 5 6 X 11 Thisoptional feature is onlyfor those applicationswhich require connectionto a facility'sEmergencyPowerOff(EPO) circuit.Whenthe UPS System isconnected to this circuit,it enables emergenc y shutdownof theoutput. Using a[...]

  • Page 12

    UPS System Batter y Back Co nnec to r White wir e Blue wire UPS System Batter y Back Co nnec to r Fu se Block Bracket Red wire (+ ) Black wire (–) 12 Qualifiedservice personnelshould familiarizethemselves withthe battery packwiring diagram prior toadding or replacingbatteries. Thebattery[...]

  • Page 13

    13 Placethe UPS System inBypass Mode orcompletely turn itoff, dependingon preference. (See section5.4, Operation of Manual Bypass Switch , or4.2, T urning the UPS Off .) 1 Remov e battery accesspanel, located on theFRONTof theUPS system. 2 2 Disconnect?[...]

  • Page 14

    14 Slide the battery string with the RED cable into an empty slot within the battery compartment as sho wn. Make sure that the string is oriented as shown in the diagram 7A . Note: If the auxiliary battery connector is in the way , remove its mounting screw and position the cable to allow adequate room to add the battery strings 7B . 7 7 Slide the [...]

  • Page 15

    240 15 D ANGER! B A TTER Y CARTRIDGE FUSES MUST BE INSERTED LAST DUE TO THE DANGER OF PO TENTIAL ARCING OF CONNECTORS. FUSE REPLA CEMENT The fuses protect against shor t circuit damage . If a heavy overload or shor t cir cuit is encountered, a fuse will blow . A battery pack with a blown fuse will not deliver any output v oltage to the UPS system. [...]

  • Page 16

    16 Y our SmartOnline 3-Phase UPSSystem is cov ered by thelimited warranty describedbelow . Extended warranty(2-, 3- and4-year) and start-upservice programsare av ailable. Formore information, callTrippLiteCustomer Service at(773) 869-1234. 3-Pha[...]

  • Page 17

    17 Model: SU20K3/3 Input Input Voltage 120/208V AC, 3ø, 4 Wire (plus ground), wye Input Frequency 60 Hz ± 3 Hz V oltage Correction Range 88-144/166-250V AC Input Cur rent (Per Phase, On-Line) 60A Inr ush Cur rent <300A Power Factor (Full Load) >0.95 Efficiency (Full Load/On-Line) >89% Circuit Breaker 100A (3p) Input Bypass Circuit Breake[...]

  • Page 18

    200901138 93-2624 18 Model: SU30K3/3 Input Input Voltage 120/208V AC, 3ø, 4 Wire (plus ground), wye Input Frequency 60 Hz ± 3 Hz V oltage Correction Range 88-144/166-250V AC Input Cur rent (Per Phase, On-Line) 90A Inr ush Cur rent <300A Power Factor (Full Load) >0.95 Efficiency (Full Load/On-Line) >89% Circuit Breaker 100A (3p) Input Byp[...]