Transition Networks SUBTF10XX-1XX-MX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Transition Networks SUBTF10XX-1XX-MX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Transition Networks SUBTF10XX-1XX-MX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Transition Networks SUBTF10XX-1XX-MX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Transition Networks SUBTF10XX-1XX-MX should contain:
- informations concerning technical data of Transition Networks SUBTF10XX-1XX-MX
- name of the manufacturer and a year of construction of the Transition Networks SUBTF10XX-1XX-MX item
- rules of operation, control and maintenance of the Transition Networks SUBTF10XX-1XX-MX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Transition Networks SUBTF10XX-1XX-MX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Transition Networks SUBTF10XX-1XX-MX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Transition Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Transition Networks SUBTF10XX-1XX-MX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Transition Networks SUBTF10XX-1XX-MX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User ’ s Guide SIBTF10xx-1xx-MR & SIBTF10xx-1xx-MS Substation-Rated Industrial Ethernet Switch • 10/100Base-TX to 100Base-FX • Single or Redundant Wide Input Power Supply The SIBTF10xx-1xx-Mx Ethernet industrial switches allow connecting 10Base-T Ethernet/100Base-TX fast Ethernet twisted-pair copper network devices to network devices on a[...]

  • Page 2

    2 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Available SIBTF10xx-140-MR and MS models* *MR = Redundant power-supply terminal blocks, MS = Single power-supply terminal block. Note: The cable distances listed are maximum distances typically. The actual distance is dependent upon the physical characteri[...]

  • Page 3

    4 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Installation F eatures • The SIBTF10xx-140-MR industrial switch includes four (4) RJ-45, twisted-pair copper ports and one (1) 100 Mb fiber optic port. • The Auto-Negotiation feature on port “1” can be turned OFF and forced to a selected speed (100[...]

  • Page 4

    6 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Figure 3: SIBTF10xx-110-MR Front Panel Installation -- continued F eatures -- continued • The SIBTF10xx-110-MS industrial switch includes one (1) RJ-45, twisted-pair copper port and one (1) 100 Mb fiber optic port. • The Auto-Negotiation feature on por[...]

  • Page 5

    8 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Installation -- continued DIP switc h settings 1. Port 1 copper Auto-Negotiation: UP (Enabled) - Advertises switch speed and mode capabilities to the network: • 100Mb/s full-duplex • 100Mb/s half-duplex, • 10Mb/s full-duplex • 10Mb/s half-duplex. D[...]

  • Page 6

    10 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Installation -- continued Note: DO NOT use bare (exposed) or un-lugged power-source wires to connect to the industrial switch. Connecting primar y pow er The industrial switch is designed to accommodate 48 – 170VDC or 90 – 125VAC, 50/60 Hz input power[...]

  • Page 7

    Installation -- continued Internal rela y connections The internal relay can activate an external fault indicator. The fault indicator connects to the relay contacts on the front panel. An example would be a fault circuit connected to a warning light located in a control room. The light can be connected in a normally open (NO) or normally closed (N[...]

  • Page 8

    14 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Installation -- continued Installing fiber cable To install a fiber cable, view Figure 10, and then do the following: 1. Locate or build 100Base-FX fiber cable with male, two-stranded TX to RX connectors installed at both ends. 2. Connect the fiber cables to the industria[...]

  • Page 9

    16 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Oper ation -- continued C opper/fiber status LEDs -- continued Copper LEDs The function of the copper port LEDs (1, 2, 3, and 4) are as follows: 100MB ON The copper port has established a link at 100 MB/s. 100MB Flashing The copper port is transmitting signals at 100 Mb/s[...]

  • Page 10

    18 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Oper ation -- continued Product features -- continued Auto-Negotiation The Auto-Negotiation feature allows the SIBTF10xx-1xx industrial switch to configure itself to achieve the best possible mode of operation over a link automatically. The industrial swi[...]

  • Page 11

    techsupport@transition.com -- Click the “Transition Now” link for a live Web chat. 21 C able Specifications -- continued SIBTF1013-1xx-Mx 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB SIBTF1014-1xx-Mx 1310 nm single mode Fiber-o[...]

  • Page 12

    22 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 T echnical Specifications For use with Transition Networks Model SIBTF10xx-1xx-Mx or equivalent. Standards: IEEE 802.3™ 2000, IEEE 802.3x™ Data Rate: 10 Mb/s, 100 Mb/s (copper) , 100 Mb/s (fiber) Dimensions: Models 130- & 140-Mx (W x H x D) 4.125&[...]

  • Page 13

    24 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Standard Description Compliance Level Remarks IEEE1613, Power Substation Testing -- Continued IEEE1613, Clause 7.3.2 Class 2 transverse mode Class 1 common mode Surge fast transient waveform – power AC Class 2 transverse mode Class 1 common mode Surge f[...]

  • Page 14

    26 SIBTF10xx-1xx-Mx 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 Contact Us Technical support Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600 Transition now Chat live via the Web with Transition Networks Technical Support. Log onto w ww.transition.com and cl[...]

  • Page 15

    Trademark Notice All trademarks and registered trademarks are the property of their respective owners. Copyright Restrictions © 2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or means (graphic, electronic, mechanical) without written permission from Transition Networks. Printed in the U.S.[...]