Trane FURN-PRC001-EN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Trane FURN-PRC001-EN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Trane FURN-PRC001-EN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Trane FURN-PRC001-EN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Trane FURN-PRC001-EN should contain:
- informations concerning technical data of Trane FURN-PRC001-EN
- name of the manufacturer and a year of construction of the Trane FURN-PRC001-EN item
- rules of operation, control and maintenance of the Trane FURN-PRC001-EN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Trane FURN-PRC001-EN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Trane FURN-PRC001-EN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Trane service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Trane FURN-PRC001-EN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Trane FURN-PRC001-EN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Upflo w/Horizontal Right or Upflo w/Horizontal Left Induced Draft Gas Furnace XR 80 TUD040,060,080,100,120,140C Single-Stage F an Assisted Comb ustion System PUB. NO . 22-1640-06-0702 (EN) FURN-PRC001-EN[...]

  • Page 2

    © 2002 American Standard Inc. All Rights Reserved 2 22-1640-06-0702 (EN) General Featur es Natural Gas Models Central Heating furnace designs are cer tified by the American and Canadian Gas Associations for both natur al and L.P . gas . Limit setting and rating data were estab lished and approved under standard rating conditions using American Nat[...]

  • Page 3

    22-1640-06-0702 (EN) 3 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6 TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K 7 TUD080C936K 7 TUD080C948K 7 TUD080C960K 7 TUD100C936K 8 TUD100C945K 8 TUD100C948K 8 TUD100C960K 8 TUD100C972K 9 TUD120C954K 9 TUD120C960K 9 TUD140C9[...]

  • Page 4

    4 22-1640-06-0702 (EN) Featur es and Benefits • P o wer supply 115/1/60 • Multi-por t In-shot b ur ners • Integrated solid state control with self diagnostics • Silicon Nitride hot surface igniter with adaptive heat up • Complete front service access • Heavy guage aluminized steel heat exchanger • Slide out bl ower assemb ly • Blowe[...]

  • Page 5

    22-1640-06-0702 (EN) 5 Optional Equipment Thermostat .............................................................................................................................................................. BA Y ST A T388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Hor izontally) .......................................................[...]

  • Page 6

    6 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el. F or Canadian applications, above input r atings (BTUH) are up to 4,500 feet, derate 4% per[...]

  • Page 7

    22-1640-06-0702 (EN) 7 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel. F or Canadian applications, abov e input ratings (BTUH) are up to 4,500 feet, der ate 4% pe[...]

  • Page 8

    8 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el. F or Canadian applications, above input r atings (BTUH) are up to 4,500 feet, derate 4% per[...]

  • Page 9

    22-1640-06-0702 (EN) 9 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel. F or Canadian applications, abov e input ratings (BTUH) are up to 4,500 feet, der ate 4% pe[...]

  • Page 10

    10 22-1640-06-0702 (EN) Per for mance Data FURN AC E AIRFLO W (CFM) VS. ST A TIC PRESSU RE (ins. w .g.) M OD EL SP EE D T AP 0.1 0 0.2 0 0.3 0 0.4 0 0.5 0 0.6 0 0.7 0 0.8 0 0 .90 TUD040C924K 4 - 3 - 2 - 1 - HIGH - Bla ck ME D . -HIGH - Blue ME D .-LO W - Y ello w LOW - Red 1018 847 716 617 1004 832 701 599 982 809 678 575 950 779 648 544 910 742 61[...]

  • Page 11

    22-1640-06-0702 (EN) 11 Per for mance Data FURNACE AI RFL O W (C FM) VS. ST A T I C PR ESSURE ( i ns. w . g. ) M O DE L S P E E D T A P 0 .10 0 .20 0 .30 0 .40 0 .50 0 .6 0 0 .70 0 .80 0 .90 TUD1 00 C97 2K BO TTOM AND LEFT SIDE RET URN 4 - 3 - 2 - 1 - HI GH - Bl ack M E D .-H I G H - B lue M E D .-LO W - Y e l lo w LO W - Red 2484 2458 2432 2387 23[...]

  • Page 12

    12 22-1640-06-0702 (EN) Field Wiring F rom Dwg. 21B341437 Rev . 1 F rom Dwg. 21B341436 Re v . 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without T ransformer) Field Wiring Diagram For Heating Onl y[...]

  • Page 13

    22-1640-06-0702 (EN) 13 F rom Dwg. 21B341423 Rev . 1 F rom Dwg. 21B341422 Rev . 1 T winning Field Wiring[...]

  • Page 14

    14 22-1640-06-0702 (EN) F rom Dwg. 21C341699 Re v . 1 TUD-C Outline Drawing (All dimensions are in inches)[...]

  • Page 15

    22-1640-06-0702 (EN) 15 Electrical Data Schematic Diagrams f or Gas Furnaces F rom Dwg. 21D341704 Rev . 1[...]

  • Page 16

    P .I. T rane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. T rane A business of American Standard Companies www .trane.com Literature Order Number FURN-PRC001-EN File Number — Supersedes TUD-D-1 3/98 Stocking Location PI Louisville & Webb/Mason-Hou[...]