Toshiba LF654 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Toshiba LF654, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Toshiba LF654 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Toshiba LF654. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Toshiba LF654 should contain:
- informations concerning technical data of Toshiba LF654
- name of the manufacturer and a year of construction of the Toshiba LF654 item
- rules of operation, control and maintenance of the Toshiba LF654 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Toshiba LF654 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Toshiba LF654, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Toshiba service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Toshiba LF654.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Toshiba LF654 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TIC-LF654L Introduction The electromagnetic flowmeter uses Faraday’s Law of electromagnetic induction to measure the process flow. The device consists of two units: a detector, through which the fluid to be measured flows and in which low-level signals proportional to flow rates are obtained; and a converter, which supplies excitation current to [...]

  • Page 2

    TIC-LF654L 2 Fluid conductivity: 3µS/cm minim um Fluid temperature: -4 to 248 °F ( - 20 to +120 °C): PFA lined flowmeter -4 to 140 °F ( - 20 to +60 °C): Polyurethane lined flowmeter 23 to 176 °F ( - 5to +80 °C): Hard Rubber lined flowmeter Ambient temperature: -40 to 140 °F ( - 40 to +60 °C): PFA lined flowmeter -4 to 140 °F (-20 to +60 ?[...]

  • Page 3

    TIC-LF654L 3  Model LF620 and LF622 converters Input signals Analog signal — the voltage signal from detector, proportional to process flow rate (for LF622 separate type converter). Digital input DI Signal type: 20 to 30Vdc voltage signal Input resistance: 2.7k  Number of inputs: one point Note: DI cannot be used with the Modbus communicati[...]

  • Page 4

    TIC-LF654L 4 LCD display: Full dot-matrix 128×128 dot LCD displ ay (back–light provided) A parameter change will rotate the display. Parameter settings — Parameters can be set as follows: • IR Swit ches : Three key switches are provided to set configuration parameters. • Digital communication : HART, PROFIBUS or Modbus is needed to set par[...]

  • Page 5

    TIC-LF654L 5 Installation  Dimensions Note1: Eye bolts ar e provided at the top f or flowmeters sized 8" (200 mm) or above, and further, a roll-p revention base is provided for flowmeters sized 10" (250mm) or larger. Note2: Cable glands are not provided for LF654 of cFMus approved type. Refer to the cable connection port at converter. [...]

  • Page 6

    TIC-LF654L 6 ASME B 16.5 class 150 dimensions: EN 1092-1 PN16 dimensions: Meter size (mm) L1 (mm) L2 (mm) L3 (mm) No. of bolts Weight (kg) 15 200 203 251 4 a p p r ox . 6 . 0 25 200 209 272 4 a p p r ox . 7 . 5 32 200 217 285 4 a p p r ox . 1 0 . 0 40 200 218 288 4 a p p r ox . 1 0 . 5 50 200 232 310 4 a p p r ox . 1 5 . 0 65 2 0 0 237 325 4 approx[...]

  • Page 7

    TIC-LF654L 7 ASME B 16.5 class 150 dimensions: Meter size (inch) L1 (inch) L2 (inch) L3 (inch) No. of bolts Weight (lbs) 1/2 5.51 6.77 8.54 4 appr ox. 9.0 1 6.30 7.01 9.13 4 approx. 14.0 1-1/4 7.87 7.32 9.65 4 approx. 18.0 1-1/2 6.69 7.36 9.88 4 approx. 18.0 2 7.09 7.80 10.79 4 approx. 27.0 2-1/2 7.87 7.99 11.50 4 approx. 36.0 3 9.06 8.39 12.13 4 a[...]

  • Page 8

    TIC-LF654L 8 ASME B 16.5 class 150 dimensions: Meter size (inch) L1 (inch) L2 (inch) L3 (inch) No. of bolts Weight (lbs) 1/2 7.90 6.77 8.54 4 approx. 9.0 1 7.90 7.01 9.13 4 approx. 14.0 1-1/4 7.90 7.32 9.65 4 approx. 18.0 1-1/2 7.90 7.36 9.88 4 approx. 18.0 2 7.90 7.80 10.79 4 approx. 27. 0 2-1/2 7.90 7.99 11.50 4 approx. 36.0 3 7.90 8.39 12.13 4 a[...]

  • Page 9

    TIC-LF654L 9 Figure 7. Separate type converter LF622 and LF622F  External Connections ● Combined type LF650/LF620 flowme ter and LF654/LF620F flowmeters Grounding w it h 100 Ω or les s ground res is t anc e I ns t ru m ent panel : Ordered s eparat el y I / O c able Ⅳ wi r e 5 . 5 m m 2 or m ore C urrent out put ( 4 ∼ 20m Adc ) or PR OF I [...]

  • Page 10

    TIC-LF654L 10 ● Separate type LF650/LF622 flowmeter and LF654/LF622F fl owmeter G roun di ng w it h 100 Ω or l es s ground resis t anc e I ns t rum e n t pane l : O r d ere d s epa ra t e l y I / O c able G round ing w it h 1 0 0 Ω or l es s ground res is t anc e Ⅳ w ire 5. 5m m 2 or m ore C u rre nt outpu t (4 ∼ 20 m A d c ) o r PR O FI B [...]

  • Page 11

    TIC-LF654L 11  Wiring Precautions (1) Explosion proof type flowmeters are not provided with cable glands. Refer to the part Cable connection port at detector and converter. (2) Connect the grounding wire (IV wire 5.5mm ² or more) to a good earth ground (100  or less ground resistance). Make the wire as short as possible. Do not use a common [...]

  • Page 12

    TIC-LF654L 12 T able 3. Flow Rate and Flow velocity (SI unit) Unit: m 3 /h Size (mm) Flow rate 0.1 m/s 0.3 m/s 1.0 m/s 3.0 m/s 12 m/s 15 0.06362 0.1908 0.6361 1.908 7.634 25 0.1767 0.5301 1.767 5.301 21.21 32 0.2895 0.8686 2.895 8.686 34.74 40 0.4523 1.357 4.523 13.57 54.29 50 0.7067 2.120 7.067 21.20 84.82 65 1.195 3.583 1 1.95 35.83 143.4 80 1.80[...]

  • Page 13

    TIC-LF654L 14 T able 4. Specification Code (Flange type detector LF654 Series) Model Spec ification Code Descripti on Detector ca tegory 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Gr.-A Gr.-B L F 6 5 Flange type electroma gnetic flowme ter detector 4 Usage cFMus Class 1 Division 2 Hazardous Location √ √ M e t e r s i z e D ½ " ( 1 5 m m ) √ E 1&q[...]

  • Page 14

    TIC-LF654L 15 T able 5. Specification Code for co nverters Model Spec ification Code Contents LF620 type LF622 type 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 L F 6 2 Electromagnetic flowmeter converter 0 Combined (Integral) type   – 2 Separate (Remote) type –  F P u r p o s e cFMus class I, Division 2 approved   A S h a p e Standard type[...]