A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Thermo Products USDT2004, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Thermo Products USDT2004 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Thermo Products USDT2004. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Thermo Products USDT2004 should contain:
- informations concerning technical data of Thermo Products USDT2004
- name of the manufacturer and a year of construction of the Thermo Products USDT2004 item
- rules of operation, control and maintenance of the Thermo Products USDT2004 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Thermo Products USDT2004 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Thermo Products USDT2004, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Thermo Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Thermo Products USDT2004.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Thermo Products USDT2004 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    USDT 2004 Installation and User’s Guide Introduction General Information 2 Installation 3 Collector Sensor 3 Control Box 5 Power Connection 6 Display Window 6 Operation Basic Operation (Factory Setting for Only Two Sen sors) 7 Manual Operation Mode 8 Three Sensor Operation 9 Sensor Selection 11 Alarm Functions and Diagnostics 12 Energy Calculatio[...]

  • Page 2

    2 Introduction Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express or implied, or to form any contract. Thermo Technologies reserves the right to change specifications without prior notice. SDT 2004 is a powerful temperature differential control unit. It has *two progra[...]

  • Page 3

    3 INSTALLATION Note: This installation procedure is for guidance only, and the installer should verify its suitability. Make sure that the solar system is physically installed, manually tested, and ready for controlled operation. he following sa fety precautions are strongly recommended: 1. Before attempting to install and operate the unit read thi[...]

  • Page 4

    4 strap the sensor to the collector outl et pipe or the absorber (flat plate collectors) that projects from the collector housing. Ideally, house the collector sensor (encased in a suitable sensor pocket) into a T - piece on the collector return outlet. Protect the sensor cable from UV and moistur e. l Return (tank) sensor (white cable): The sensor[...]

  • Page 5

    5 Undo the screw at the top of the housing. The control electronics are mounted on the enclosure cover. The controller enclosure can be screwed to the wall with cable entry grommets pointed downwards. Use the supplied plastic bridges to secure pow er and sensor cables. Base of the unit to be mounted at eye - level and wired as shown above Caution: [...]

  • Page 6

    6 ower Connections: A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inse rted. NOTE 1: Always disconnect the controller from power supply before opening the housing. NOTE 2: The controller should be properly grounded. Flexible wires, 18/3 AWG (gauge/conductor) simplify connection to[...]

  • Page 7

    7 Use selection keys ïð during normal system operation to display the desired parameter: T1 xxx Collector temperature in o F T2 xxx Tank temperature in o F T3 xxx Reading of the third sensor; if the third sensor is not used it displays a fixed reference temperature of 250 o F XX xxx Collector power in [kW] YY xxx Energy collected in [MWh] ZZ xxx [...]

  • Page 8

    8 RUV X.X – This display shows the software revision number. NR O – This is PROGRAM 0 which indicates simple operation of unit as a U niversal S olar D ifferential T emperature ( USDT ) controller. Change this value to 1 ( NR 1 ) for activation of the third sensor or puls e flow meter input (PROGRAM 1) . Hysteresis Bandwidth User can program hy[...]

  • Page 9

    9 symbol while the pump is running. User can switch to manual mode by pressing ò k ey. By pressing ð key while centerline blinks, a hand symbol G in lower line shows manual operation. Pressing ð one more time lets you turn the pump ON or OFF . By pressing ñ key you change the pump operation. Advanced Operation (Setting for Three Sensors and Flo[...]

  • Page 10

    10 max = 2 Pump runs again below this set point (T3) Energy calculation mode (PROGRAM 1) : USDT 2004 computes the energy production as a function of the temperature diff erential and fluid volume. In addition, the system anti - freeze (Glycol) percentage should be entered as it affects the thermal conductivity and heat transfer rate. Press the Adva[...]

  • Page 11

    11 START Starts pump at pre - set insolation (solar radiation intensity) ALARM Enables/Disables protection functions BTU Energy calculation and setting ensor Designation – USD T 2004 accepts two different sensor types or a reference value . User can program a constant reference temperature instead of a sensor output. The factory - preset sensor i[...]

  • Page 12

    12 circulation pump runs when the collector temperature is below a programmable minimum temperature, shown by = symbol. The pump stops as soon as the temperature in the solar loop reaches a safe region programmed by the ? symbol. This feature is also disabled at the factory by entering - 4 o F. min = Pump runs below this temperature min ? Pump stop[...]

  • Page 13

    13 2 OPEN Disconnection in sensor 2 wiring OK System operates normal NO CIRC r T is more than 108 o F in last 30 minutes OK CIRC Pump is running CLEAR Clears NO CIRC display after correction nergy calculation - Energy gain is calculated by obtaining the temperature increase of heat transfer fluid across the solar collector. The amount of fluid flow[...]

  • Page 14

    14 T roubleshooting In general, all of the settings in the menus Par and Men and the terminal should f irst be checked if there is a malfunction. Malfunction, but "realistic" temperature values: • Check program number. • Check the switch - on and switch - off thresholds and the set differential temperatures. Have the thermostat and di[...]