Therma-Tru Light Commercial Doors and Frames manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Therma-Tru Light Commercial Doors and Frames, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Therma-Tru Light Commercial Doors and Frames one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Therma-Tru Light Commercial Doors and Frames. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Therma-Tru Light Commercial Doors and Frames should contain:
- informations concerning technical data of Therma-Tru Light Commercial Doors and Frames
- name of the manufacturer and a year of construction of the Therma-Tru Light Commercial Doors and Frames item
- rules of operation, control and maintenance of the Therma-Tru Light Commercial Doors and Frames item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Therma-Tru Light Commercial Doors and Frames alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Therma-Tru Light Commercial Doors and Frames, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Therma-Tru service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Therma-Tru Light Commercial Doors and Frames.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Therma-Tru Light Commercial Doors and Frames item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Therma-T ru ® Light Commercial/Multi-Family - Doors and Frames 1 • Material shown on these dra wings will be fabricated only after formal approv al by the arc hitect, receipt of approv al hardware sc hedule, and all necessary hardw are templates. • All frames shall be shipped “knoc ked-down” unless otherwise specied. • All frames and [...]

  • Page 2

    2 REMARKS WIDTH HEIGHT JOB NUMBER PROJECT SHEET NUMBER OF LOCATION LOCK CLOSER FLUSH BOL TS HRDWR. SET/ HDG. GAUGE SHEET ELEV . LABEL HINGE JAMB DEPTH OVERALL HEIGHT ANCHOR DOOR CONSTR. DOOR OPENING DOOR THICK. SHEET ELEV . SHEET SECT . ITEM QUANTITY ARCH MARK FROM TO SWING FRAME CONSTR. GAUGE LOCATION FRAME DATA DOOR DATA HARDWARE Therma-T ru ® L[...]

  • Page 3

    3 DOOR ELEV A TIONS - FLUSH - LITED DOOR ELEV A TIONS - EMBOSSED - OP AQUE Therma-T ru ® Light Commercial/Multi-Family - 22-Gauge & 24-Gauge Steel Doors EXPOSED GLASS SIZE: 3” x 33” EXPOSED GLASS SIZE: 4” x 25” EXPOSED GLASS SIZE: 5” x 20” 3” 4” 5” 33” 25” 20” EXPOSED GLASS SIZE: 10” x 10” EXPOSED GLASS SIZE: 22” [...]

  • Page 4

    4 Therma-T ru ® Light Commercial/Multi-Family - FG Doors DOOR ELEV A TIONS - SMOO TH DOOR ELEV A TIONS - GRAINED STYLE# FCF160 STYLE# FCF140 STYLE# FCF100 STYLE# SSF960 STYLE# SSF200 STYLE# SSF160 STYLE# SSF100[...]

  • Page 5

    5 Therma-T ru ® Light Commercial/Multi-Family - Standard Hardware Preps. STEEL DEADBOL T PREP: ST AMPED 1 1/8" x 2 3/4" OPTIONAL DEADBOL T PREP FOR STEEL FRAMES. AV AILABLE WITH ADJUST A-FIT , ADJUST A-TRIM, HOLLOW MET AL, SECURA-FIT & VIST A III FRAMES. STEEL DEADBOL T PREP ST AMPED 1 1/18" x 2 3/4" OPTIONAL DEADBOL T PREP[...]

  • Page 6

    6 Therma-T ru ® Light Commercial/Multi-Family - Hardware Locations NOMINAL 2-0 2-4 2-6 2-8 2-10 3-0 3-6 ACTUAL 23 11/16" 27 11/16" 29 11/16" 31 11/16" 33 11/16" 35 11/16" 41 11/16" NOMINAL 6-8 7-0 8-0 ACTUAL 78 5/8" 82 1/8" 93" MORTISE PREP 45 1/4" 45 1/4" 59 5/8" CYLINDRICAL PREP 44[...]

  • Page 7

    7 Therma-T ru ® Light Commercial/Multi-Family - Custom Elevations/Applications JOB NUMBER PROJECT LOCATION SHEET NUMBER OF[...]

  • Page 8

    8 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 3-6 x 6-8 4 7/8" ANSI (STD) 2-0 x 7-0 2-4 x 7-0 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 3-6 x 7-0 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 5/8" [...]

  • Page 9

    9 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49 1/2" 5-0 = 61 1/2" 5-4 = 65 1/2" 6-0 = 73 1/2" ADJUST A-FIT FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-FIT FRAME INACTIVE HINGE JAMB 4&q[...]

  • Page 10

    10 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Single FRAME DET AIL EXISTING WALL ADJUST A-TRIM CLOSURE JAMB COMPRESSION WEA THERSTRIPPING COMPRESSION WEA THERSTRIPPING STEEL ENTRANCE DOOR 2-0 = 24" 2-4 = 28" 2-6 = 30" 2-8 = 32" 2-10 = 34" 3-0 = 36" 3-6 = 42" 2-10 = 35" 3-0 = 37&q[...]

  • Page 11

    11 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49" 5-0 = 61" 5-4 = 65" 6-0 = 73" WOOD SP ACER ADJUST A-TRIM FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-TRIM FRAME INACTIVE HINGE JAMB 4[...]

  • Page 12

    12 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 2-0 x 7-0 T-STRIKE (STD) 2-4 x 7-0 T-STRIKE w/ DEADBOLT 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH H[...]

  • Page 13

    13 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Double 4-0 x 6-8 5-0 x 6-8 5-4 x 6-8 6-0 x 6-8 SPRING LOADED 4-0 x 7-0 BALL BEARING 5-0 x 7-0 5-0 x 7-0 T-STRIKE (STD) 6-0 x 7-0 T-STRIKE w/ DEADBOLT JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH HEIGHT 47 3/4" - 48" 79 7/8"[...]