Teledyne 3000TA-XL-EU manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Teledyne 3000TA-XL-EU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Teledyne 3000TA-XL-EU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Teledyne 3000TA-XL-EU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Teledyne 3000TA-XL-EU should contain:
- informations concerning technical data of Teledyne 3000TA-XL-EU
- name of the manufacturer and a year of construction of the Teledyne 3000TA-XL-EU item
- rules of operation, control and maintenance of the Teledyne 3000TA-XL-EU item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Teledyne 3000TA-XL-EU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Teledyne 3000TA-XL-EU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Teledyne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Teledyne 3000TA-XL-EU.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Teledyne 3000TA-XL-EU item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Teledyne Analytical Instruments QUICKS T AR T GUIDE M O D E L 3 0 0 0 T A - X L - E U T ra ce Oxygen Analyzer[...]

  • Page 2

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments[...]

  • Page 3

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 1 GETTING S T ARTED This Quickstart Guide is designed to get you s et up and ope rating your Teledyne An a lytical Instruments Analyzer quickly. It shortcuts the details so you can install and use your new analyzer with a minimum of fuss. This Quicksta rt Guide should be used in c[...]

  • Page 4

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 2 Function Keys : Six touch-sensiti v e membrane swit ches are used to cha ng e the specific function performed by the analyzer: • Analyze Perform anal ysis for oxygen cont ent of a sample gas. • System Perform system-relate d tasks (describ ed in detail in chapter 4, Operat[...]

  • Page 5

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 3 Rear Panel (Equipment Int erfa ce) At the rea r pane l you make the gas and electrical connections to the instrument. • Power Connection: Universal AC power source. • Gas Inlet and Outlet: One inlet and one exhaust out. • RS-232 Port : Serial di gital con centration signal[...]

  • Page 6

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 4 SETUP AND INS T ALL Mount the Ana lyzer The Model 3000T A -EU is for indoor use in a general purpose area. It is NOT for ha zardous environme nts of any type. It is design ed fo r f lush p anel m ount ing. Us e t he fou r m ount ing h ole s— on e i n each corn er of t he r i[...]

  • Page 7

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 5 Electrical Connections CAUT ION: RE AD ALL SAFETY INFORMATION REGARDING ELECTRICAL HAZARDS ASSOC IATIED WITH THIS I NSTRUMENT BEF ORE MAKING ELECTRICAL CONNECTIONS. CAUT ION: POW ER IS APPLIED TO THE INSTRUMENT'S CIRCUITRY AS LONG AS THE INSTRU MENT IS CONNE CTED TO THE POW[...]

  • Page 8

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 6 • Install 50-Pin Equipment Interface Connector Connect t h e 50 pin c onn ector to the mating connector on the rear panel. • Connect the 9-pin D conn ector to the RS-232 serial port. See Secti on 3.3.2.3 in the Instruction Manual for information on setting up serial commun[...]

  • Page 9

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 7 1. Place t he c ell on t h e holder with the screen side faci ng down. Note: There is a small location hole drilled in the holder. This hole mates with a guide pin on th e bottom rear of the cell blo ck. The hole in the cell block holder must align with the guide pin on t he cel[...]

  • Page 10

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 8 BASIC OPER A TION Once the a naly zer has been installed, it can be configured for your application. Prior to using the instrument you m ust : • Calibrate t he instrument • Define the analysis r anges and choose whether to use autoranging or a fixed range. • Set ala rm s[...]

  • Page 11

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 9 A vailab le Functions The six function butt ons are used to control the analyzer. Some functi ons have submenus that allow additional choices as s hown below.[...]

  • Page 12

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 10 Any function ca n be sel ected at any time by pressing the appropriate button (unless password restrictions appl y). Password Protection If a password is assigned, then setting the following system parameters can be done only after t he passw ord is entered: span and zero set[...]

  • Page 13

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 11 ◄► arrow keys to scroll back a nd forth b e tween letters, and the ▲▼ arrow keys to change t he l etters to the proper password. • Press Enter to enter the pa ssword. Change Password? <ENT>=Yes <ESC>=No • Press Escape . Calibration of the Analyzer For tr[...]

  • Page 14

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 12 The ze roing proc ess will automatically conclude when t he output is w ithin t h e acceptable range for a good zero. Then the analyzer automatically returns to the Analyze mode. Manual Mode Zeroi ng • Press Zero to enter the Zero function. • Use the ▲▼ keys to toggle[...]

  • Page 15

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 13 #### pp m Sp a n Slop e=#### ppm/s The instrument a utomati cally returns to the Analyze mode at the conclusion of the auto span cycle .. Manual Mode Spanning: • Press Span to start the Span function. Span: Settling:MAN <ENT> For Next • Use the ▲▼ keys to toggle b[...]

  • Page 16

    Quickstart Guide Trace Oxygen Analyzer Teledyne Analytical Instruments 14 • Press the Alarm button on the front panel to ente r the Alarm func tion. Make sure that AL–1 is blinking. AL—1 AL —2 Choose Al arm • Using the ◄► arrow keys to move the b linking over to AL–1. Then press Enter . AL—1 1000 ppm HI Dft—N Fs—N Ltch—N Fiv[...]

  • Page 17

    Model 3000 TA-XL-EU Quickstart Guide Teledyne Analytical Instruments 15 • Use the ◄► arrow keys to blink the r ange to be set: low (L), medium (M), or high (H). • Use the ▲▼ arrow keys to enter t he uppe r value of t he rang e (all ranges begin at 0 ppm). Repeat for each range you want t o s et. • Press Enter to accept the values and [...]