Tektronix PS280 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Tektronix PS280, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Tektronix PS280 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Tektronix PS280. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Tektronix PS280 should contain:
- informations concerning technical data of Tektronix PS280
- name of the manufacturer and a year of construction of the Tektronix PS280 item
- rules of operation, control and maintenance of the Tektronix PS280 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Tektronix PS280 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Tektronix PS280, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Tektronix service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Tektronix PS280.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Tektronix PS280 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User Manual PS280 & PS283 DC Power Supplies 070-8355-03[...]

  • Page 2

    Copyright  T ektronix, Inc. 1991. All rights reserved. T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. T ektronix, Inc., P .O. Box 1000, W ilsonville, OR 97070–1000 TEKTRONI[...]

  • Page 3

    W ARRANTY T ektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, T ektronix, at its option, either will repair the defective product without charge for parts and labor , or will provide a re[...]

  • Page 4

    [...]

  • Page 5

    PS280 & PS283 User Manual i T able of Contents General Safety Summary iii . . . . . . . . . . . . . . . . . . . . . . . . . . . . Getting Started 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparing the Power Supply for Use 2 . . . . . . . . . . . . . . . . . . . . . Front Panel 4 . . . . . . . . . . . . . . . .[...]

  • Page 6

    T able of Contents ii PS280 & PS283 User Manual List of Figures Figure 1: Line V oltage Selectors, Power Input, and Fuse Locations 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2: PS280 or PS283 Front Panel 4 . . . . . . . . . . . . . . . . . . . Figure 3: Constant V oltage/Constant Current Crossover 10 . . . . . . Figu[...]

  • Page 7

    PS280 & PS283 User Manual iii General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Injury Precautions Use Proper Power Cord T o avoid fire hazard, use only the power cord specified for this product. A void Electric Overload T o avoid electric shock or [...]

  • Page 8

    General Safety Summary iv PS280 & PS283 User Manual Do Not Operate in Wet/Damp Conditions T o avoid electric shock, do not operate this product in wet or damp conditions. Do Not Operate in Explosive Atmosphere T o avoid injury or fire hazard, do not operate this product in an explosive atmosphere. Product Damage Precautions Use Proper V oltage [...]

  • Page 9

    General Safety Summary PS280 & PS283 User Manual v CAUTION. Caution statements identify conditions or practices that could r esult in damage to this pr oduct or other pr operty . T erms on the Product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. W ARNING indicates an in[...]

  • Page 10

    General Safety Summary vi PS280 & PS283 User Manual[...]

  • Page 11

    PS280 & PS283 User Manual 1 Getting Started The T ektronix PS280 or PS283 Laboratory DC Power Supply is a multifunction bench or portable instrument. This regulated power supply provides a fixed 5 V output for powering logic circuits and two variable outputs for a wide variety of test and experimental uses. The PS280 or PS283 contains two ident[...]

  • Page 12

    Getting Started 2 PS280 & PS283 User Manual Preparing the Power Supply for Use Check the following items prior to operating the Laboratory DC Power Supply for the first time (see Figure 1 for locations of items 1 through 3): 1 3 2 Figure 1: Line V oltage Selectors, Power Input, and Fuse Locations CAUTION. T o pr event damage to the instrument, [...]

  • Page 13

    Getting Started PS280 & PS283 User Manual 3 occurs. Refer to Appendix C: Replaceable Parts on page 33 for fuse part numbers. W ARNING. T o pr event electrical shock, connect the power cor d to a pr operly gr ounded power sour ce. The outside (ground) of this connector is connected thr ough the equipment to the power sour ce gr ound. Do not r em[...]

  • Page 14

    Getting Started 4 PS280 & PS283 User Manual Front Panel Figure 2 shows the front-panel controls, connectors, and indicators with brief descriptions following the figure. 13 4 5 6 8 22 19 18 15 12 1 1 13 17 21 9 27 20 16 14 10 Figure 2: PS280 or PS283 Front Panel 1. LED Display . Lights when the instrument is turned on. The numbers indicate the [...]

  • Page 15

    Getting Started PS280 & PS283 User Manual 5 3. AMPS Indicator . Lights when AMPS is selected with the AMPS/VOL TS switch for the left variable power supply . 4. VOL TS Indicator . Lights when VOL TS is selected with AMPS/VOL TS switch for the left variable power supply . 5. AMPS Indicator . Lights when AMPS is selected with the AMPS/VOL TS swit[...]

  • Page 16

    Getting Started 6 PS280 & PS283 User Manual 13. Output T erminals. These terminals for the left, variable power supply allow you to plug in the test leads as follows: H The red terminal on the right is the positive polarity output terminal. It is indicated by a + sign above it. H The black terminal on the left is the negative polarity output te[...]

  • Page 17

    Getting Started PS280 & PS283 User Manual 7 17. Output T erminals. These terminals for the right, variable power supply allow you to plug in the test leads as follows: H The red terminal on the right is the positive polarity output terminal. It is indicated by a plus (+) sign above it. H The black terminal on the left is the negative polarity o[...]

  • Page 18

    Getting Started 8 PS280 & PS283 User Manual T urning On the Instrument After you have ensured that the PS280 or PS283 is set up for the proper line voltage and has the proper fuse (refer to Pr eparing the Power Supply for Use on page 2), you are ready to turn it on. CAUTION. T o avoid damaging the PS280 or PS283, do not use it when the ambient [...]

  • Page 19

    PS280 & PS283 User Manual 9 Reference This section tells how to set the PS280 or PS283 current limit. It also explains the constant voltage/constant current crossover characteris- tic of the instrument. Finally , the section includes procedures for using the instrument in both independent and tracking modes and provides examples of a variety of[...]

  • Page 20

    Reference 10 PS280 & PS283 User Manual V O Maximum Output V oltage Constant Current Range Constant V oltage Range Crossover Point I O Maximum Output Current Figure 3: Constant V oltage/Constant Current Crossover Setting the Current Limit Before you begin using the PS280 or PS283 to power a device, you should set its current limit lower than the[...]

  • Page 21

    Reference PS280 & PS283 User Manual 11 3. Rotate the V OL T AGE knob away from zero sufficiently to light the C.C. indicator . 4. Set the meter selection switch to AMPS so that the LED display shows the current. 5. Adjust the CURRENT knob for the desired current limit. 6. Read the value shown on the LED display . This is your preset current lim[...]

  • Page 22

    Reference 12 PS280 & PS283 User Manual In stacked mode, you connect the negative output terminal of one variable power supply to the positive output terminal of the other . The stacked configuration allows you to test a circuit requiring between 30 and 60 V . A stacked configuration can be either floating or ground-referenced. Floating. In the [...]

  • Page 23

    Reference PS280 & PS283 User Manual 13 4. Plug one of the test leads into the positive output terminal. 5. Plug the other test lead into the negative output terminal. 6. Press POWER to turn of f the PS280 or PS283. 7. Clip the positive test lead to the positive pole of your device. 8. Clip the negative test lead to the negative pole of your dev[...]

  • Page 24

    Reference 14 PS280 & PS283 User Manual 5V FIXED 3A  GND  GND SLA VE MASTER Load 2 Load 1 0 to 2 A (PS280) 0 to 1 A (PS283) –5 V 3A –5 TO +25 V Load 3 0 to 2 A (PS280) 0 to 1 A (PS283) –5 TO +25 V Figure 5: Independent Common Ground-Referenced Application In this configuration, each of the variable power supplies can be varied [...]

  • Page 25

    Reference PS280 & PS283 User Manual 15 4. Set both variable supply CURRENT controls to midrange. 5. Set the AMPS/V OL TS switches for both power supplies to display volts. 6. T urn on the POWER to the PS280 or PS283. The display should read 0 V for both variable power supplies. An external meter connected across the load or load terminals shoul[...]

  • Page 26

    Reference 16 PS280 & PS283 User Manual T o test a circuit in a independent ground-referenced split application mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 6. 3. Set both variable supply VOL T AGE controls to the minimum setting. 4. Set both variable supply CURRENT controls to[...]

  • Page 27

    Reference PS280 & PS283 User Manual 17 Figure 8 shows the configuration for three ground-referenced positive power supplies. Load 3 0 to 30 V 0 to 2 A (PS280) 0 to 1 A (PS283) Load 2 0 to 30 V 0 to 2 A (PS280) 0 to 1 A (PS283) Load 1 5V 0 to 3 A 5V FIXED 3A  GND  GND SLA VE MASTER Figure 8: Three Ground-Referenced Positive Power Sup[...]

  • Page 28

    Reference 18 PS280 & PS283 User Manual 5V FIXED 3A  GND  GND SLA VE MASTER Load 2 Load 1 –5 V 0 to +60 V Figure 9: Independent Positive Stacked Application T o test a circuit in the independently stacked mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 9. 3. Set both[...]

  • Page 29

    Reference PS280 & PS283 User Manual 19 Figure 10 shows a stacked application in which you have a 0 to –60 V output from the variable power supplies and a +5 V output from the FIXED power supply . Load 2 Load 1 +5 V 0 to –60 V 5V FIXED 3A  GND  GND SLA VE MASTER Figure 10: Independent Negative Stacked Application[...]

  • Page 30

    Reference 20 PS280 & PS283 User Manual T racking Modes There are two tracking modes in which you can operate the PS280 or PS283: series and parallel. Series. In series mode, the positive output terminal of the master variable power supply is internally connected to the negative output terminal of the slave power supply . This connection allows [...]

  • Page 31

    Reference PS280 & PS283 User Manual 21 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 12. 5V FIXED 3A  GND  GND SLA VE MASTER Load 1 0 to +60 V INTERNAL Figure 12: Series T racking Application 3. Set the PS280 or PS283 to series tracking mode by pressing the left TRACKING button. Make sure th[...]

  • Page 32

    Reference 22 PS280 & PS283 User Manual NOTE . In series tracking mode, the curr ent flowing through the two supplies must be equal. Ther efor e, the maximum curr ent limit is the lower of the values set by the two curr ent contr ol knobs. 7. T urn on the POWER to the PS280 or PS283. 8. Adjust the output voltage to the desired level using the ma[...]

  • Page 33

    Reference PS280 & PS283 User Manual 23 MASTER SLA VE Figure 13: Parallel T racking Inside the PS280 or PS283 T o test a circuit in the parallel tracking mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 14 on page 24. 3. Set the PS280 or PS283 to parallel tracking mode by pressing [...]

  • Page 34

    Reference 24 PS280 & PS283 User Manual 5V FIXED 3A  GND  GND SLA VE MASTER Load 1 0 to +30 V INTERNAL 0 to 4 A (PS280) 0 to 2 A (PS283) Figure 14: Parallel T racking Application 7. Adjust the output voltage to the desired level using the master V OL T AGE knob. 8. T urn the POWER off to the PS280 or PS283 again. 9. Connect the posit[...]

  • Page 35

    PS280 & PS283 User Manual 25 Appendix A: Specifications T able 1: Physical Characteristics Dimension Measurement Width 255 mm (10.0 in) Height 145 mm (5.7 in) Depth 335 mm (13.2 in) Weight 1 1.5 kg (25.4 lb) PS280 9.0 kg (19.9 lb) PS283 T able 2: Environmental Characteristics Characteristic T emperature Rela t ive Hum i d i ty Storage –10 _ C[...]

  • Page 36

    Appendix A: Specifications 26 PS280 & PS283 User Manual T able 3: Operational Characteristics (Cont.) Characteristic Measurement Line Regulation (CC)  0.2% +3 mA Load Regulation (5 V)  0.2% Load Regulation (CV)  0.01% +3 mV (rating current  3A )  0.01% +5 mV (rating current >3 A)  300 mV (0–60 V single series tracking sup[...]

  • Page 37

    Appendix A: Specification s PS280 & PS283 User Manual 27 T able 4: Electrical Characteristics Characteristic Measurement Line voltage 90 to 1 10 108 to 132 198 to 242 216 to 250, all V AC at 50–60 Hz Power consumption 386 V A, 300 W maximum (PS280) 265 V A, 200 W maximum (PS283) T able 5: Certifications and Compliances EC Declaration of Confo[...]

  • Page 38

    Appendix A: Specifications 28 PS280 & PS283 User Manual[...]

  • Page 39

    PS280 & PS283 User Manual 29 Appendix B: Maintenance This appendix provides information for the basic maintenance of the PS280 or PS283 Laboratory DC Power Supply . Cleaning T o clean the Laboratory DC Power Supply , use a soft cloth dampened in a solution of mild detergent and water . Do not spray cleaner directly onto the instrument, since it[...]

  • Page 40

    Appendix B: Maintenance 30 PS280 & PS283 User Manual T roubleshooting Electronic maintenance on the power supply must be performed by a trained technician. However , an operator can perform some basic and routine maintenance. Perform the following steps to isolate the fault: 1. The power switch is on. The instrument is plugged in. Neither the C[...]

  • Page 41

    Appendix B: Maintenance PS280 & PS283 User Manual 31 5. V erify that the line settings on the rear panel match the line voltage. Do they? Y es Go to step 7. No Go to step 6. 6. Reset the line settings. Refer to Pr eparing the Power Supply for Use on page 2. 7. Check the power cord. W ARNING. T o pr event personal injury , be sure the power cor [...]

  • Page 42

    Appendix B: Maintenance 32 PS280 & PS283 User Manual[...]

  • Page 43

    PS280 & PS283 User Manual 33 Appendix C: Replaceable Parts Replaceable parts may be ordered directly from your authorized T ektronix dealer . Standard Accessories The following items are shipped with the Laboratory DC Power Supply: T able 6: Standard Accessories Accessory T ektronix Part Number Fuse, 5 x 20 mm, 4 A, 250 V , SB (PS280: 90 – 13[...]

  • Page 44

    Appendix C: Replaceable Parts 34 PS280 & PS283 User Manual The following power cords are available: T able 8: Accessory Power Cords Plug Configuration Normal Usage T ektronix Part Number North America 1 15 V 161-0104-00 Europe 230 V 161-0104-06 United Kingdom 230 V 161-0104-07 Australia 230 V 161-0104-05 North America 230 V 161-0104-08 Switzerl[...]