Superior SDVI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Superior SDVI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Superior SDVI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Superior SDVI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Superior SDVI should contain:
- informations concerning technical data of Superior SDVI
- name of the manufacturer and a year of construction of the Superior SDVI item
- rules of operation, control and maintenance of the Superior SDVI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Superior SDVI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Superior SDVI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Superior service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Superior SDVI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Superior SDVI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INST ALLA TEUR: Laissez cette notice avec l'appareil. CONSOMMA TEUR : Conservez cette notice pour consul- tation ultérieure. - Do no t st or e o r us e g as ol in e or ot he r fla mm ab le va po rs an d liquids in the vicinity of this or any [...]

  • Page 2

    2 CONGRA TULA TIONS! When you purchased your new gas fireplace insert, you joined the ranks of thousands of individu als whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment. W e extend our continued support to help you achieve the maximum benefit and enjoyment available from your new ga[...]

  • Page 3

    3 IM POR T AN T SA FET Y AN D W A RN IN G IN FOR MA TI ON W ARNING Y oung chil dren shou ld be carefull y supervised when they are in the same room as the appliance. T od- dlers, young childr en and others may be susce ptibl e to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. T o restrict [...]

  • Page 4

    4  FOR YOUR SAFETY do not instal l or operat e this applianc e witho ut first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazardous.  INST ALLA TION AND REP AIR SHOULD ONL Y BE DONE BY A QUALIFIED SERVICE TECHNICI[...]

  • Page 5

    5 Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace (built to UBC 37 or ULC S628 standards) or factory built solid fuel, wood burning fireplace (listed to UL 127 or ULC S610) only . All exhaust gases must be vented outside the structure. Combustion air is drawn from outside the structure. When in[...]

  • Page 6

    6 Installation of these appliances are approved for installation in New Y ork City in the US state of New Y ork (MEA#: 138-07-E). (Massachusetts Approval #G3-0806-6) These appl iances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: • Install this appliance in accordance with Massa[...]

  • Page 7

    7 Features Installation Options Residential - Vented V ertical Only Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The blower motor requires 120 Volts AC for operation. The fireplace is not dependent on the blower or an outside electrical supply to operate. Millivolt Valve This[...]

  • Page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Insert Dimensions Minimum Fireplace Opening Required A = 31-1/4” (794mm) Front Opening B = 17-1/4” (438mm) Height C = 19” (483mm) Rear Width** D = 16” (406mm) Fireplace Depth * T op air duct will need to be removed for short ZC applications. Replace tap tights when removed. **This dime[...]

  • Page 9

    9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Facing and Mantel Side View Facing and Mantel Clearances Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or equivalent, with a k factor of .84. INSERT LEVELING At each front and rear corner of the insert is an adjustable leg provided to level the insert should the hearth[...]

  • Page 10

    10 Air In let Liner (for combustion ai r) W hen terminati ng the a ir inl et li ner at this poi nt, a positive flue connection is r equ ired (to e nsure combustion ai r is drawn down the chimney only). Ex ha ust 3" (75mm) UL 1 777 . A ful l le ngth li ner is r equ ired from the exhaust outlet on a ppl i- ance to center col lar of terminati on[...]

  • Page 11

    11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Zero Clearance Fireplace Installation This insert may be installed in a masonry or factory built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. The ZC doors, screen, refractor y or masonry lin[...]

  • Page 12

    12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 10 Surround Panels Installation The SDV I inser t surro und pan els are made of heavy gage st eel for durabi l- ity and, if desired, for the ease of making an inside fit in the fireplace. 1. Remove the speed nuts (A in Figure 12 ) from the parts bag and instal l (with th e flat surf[...]

  • Page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). These appliances and their individual shut-off valves[...]

  • Page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Moving shutter bracket to the right will open shutter , to the left will close shutter . Figure 14 Figure 15 SHUT TER ADJUSTMENT DET AIL See Detail Shutter Adjustment Shutter Adjustment Detail[...]

  • Page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. La chimenea caliente cau- sará quemaduras graves Nunca permita que los niños toquen el vidrio ni otras partes de la chimenea ADVERTENCIA Un foyer chaud peut causer de graves brûlures Ne laissez jamais un enfant toucher à la vitre ou à toutes autres parties du foyer A VE R TISSEMENT A TT [...]

  • Page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions Pre-Lighting Checklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply available - that is "natural gas" for natural gas or "LP gas" for LP gas. c Gas pressure has bee[...]

  • Page 17

    17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. T urn the gas control knob counter -clockwise to the "PILOT" position. 7. Push the knob all the way in and hold in that positio n. Immedia tely light the pilot by [...]

  • Page 18

    18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flame Color and Behavior Y our SDVI gas inser t is des ign ed for maxi mum heati ng effici en cy . Ther ef ore , upon lighting of the main burner the flames will be semi-transparent or “bluish.” After 10-20 minutes of operation the logs will heat up and the flames will become a yellow/[...]

  • Page 19

    19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Options The rocker switch on your SDVI gas insert is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to the left of the igniter button. The hole in the pa[...]

  • Page 20

    20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUTION: Wear gloves and safety glasses for protection while doing required maintenance. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé. Maintenance Checklist The following should only be performed by a q[...]

  • Page 21

    21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Glass Door Figure 20 (B) Door Mounting Plates (A) Spring Handle Latches Glass Door Removal T o remove the glass door , pull forward and up on the top latches. Lift the glass door up and off the lower spring latch. Be careful not to damage or scratch the glass while handling. T o reinstall the[...]

  • Page 22

    22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fuel Conversion Conver ting your SDVI gas inser t between natural gas and LP can be accom- plished by installing a conversion kit (valve regulator and burner orifice). Only a qualified service technician should per form the conversion. Conversion Kit: Please see instructions provided with c[...]

  • Page 23

    23 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Log Set Installation on Page 11 . If there is soot in one specific location, the rockwool below this location needs to be adjusted. This can[...]

  • Page 24

    24 T ouc h- Up Pa int K it 70 K 9 9 TS PK- B T ou c h- Up P ai nt, Me tal l i c B l ac k (1 2 oz ae r os ol) P A I N T W al l Th e rm o st a t Re m ot e Co n tr o l Co ntr ol s Ca t. No . Mo del De scr ip ti on 70 005 R T -A C Re mot e Th erm ost at A C (ref. form #775280M) H0 251 RC L-S T A T Re mot e Co ntr ol, R CL -ST A T , D el uxe Th erm os t[...]

  • Page 25

    25 Ar che d Fa ce NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4 G e a r c la m p s T erm i na ti on Ca p Fl as hi n g V e n t K its H0 9 0 9 F KD VI Fl e x L i ne r Ki t, D VI 3” X 35’ (r equ i r es 2 , o n e for ex h a us t an d o n e for in tak e ) TK D V I TK DV I T er mi nat i on Ki t , D V I ( t e rm i n at ion ca p a n d fla s [...]

  • Page 26

    26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES E = 31 .5 ” ( 80 0m m) fr om T op Fa cin g to Bo tt om of I ns er t F = 25 .5 ” ( 64 8m m) fr om C ent er o f G la ss t o S id e Fac in g or Si de W all *J = 39” (99 1m m) fr om 1 0. 5” (2 67 mm) M an tel t o Bo tto m of In se rt * S ee o wne r’ s [...]

  • Page 27

    27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION : YOU R SU PER IOR ™ G AS AP PLI ANC E MU ST ALW A YS BE OPE RA TED WI TH GLA SS DOOR IN PL ACE . STO P! Rea d t he s afe ty info rma tio n a bove be for e p roce edi ng. 1. Open the lo wer doo r . Mak e s ure gas su ppl y s hut- off co cks are op en and ON/ OFF Rock er Swi tch is [...]

  • Page 28

    Printed in U.S.A. © 2008 LHP P/N 506056-01 REV . C 03/2010 LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Y our Appliance's Model Number _______________________[...]