Sterilite S12Q manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sterilite S12Q, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sterilite S12Q one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sterilite S12Q. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sterilite S12Q should contain:
- informations concerning technical data of Sterilite S12Q
- name of the manufacturer and a year of construction of the Sterilite S12Q item
- rules of operation, control and maintenance of the Sterilite S12Q item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sterilite S12Q alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sterilite S12Q, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sterilite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sterilite S12Q.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sterilite S12Q item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t. 519.763.1032 • f. 519.763.5069 • t.f. 1.800.265.7246 e. water@r -can.com • i. www .r-can.com S12Q, S12Q-GOLD, S24Q, S24Q-GOLD, S40Q EP A # 57987-CN-001[...]

  • Page 2

    T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 W arning Systems Page 4-5 W arranty Page 5 T roubleshooting Page 6-8 Parts Page 9 Specifications Page 10 S YMBOLS : Caution Protective Ground Electric[...]

  • Page 3

    1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing. 3. DANGER - T o avoid possible electric shock, special care should be taken since water i[...]

  • Page 4

    2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter . • The disinfection system is i[...]

  • Page 5

    3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green. • Replace the UV lamp annually ( or biennially if season[...]

  • Page 6

    4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient). h) Re-tighten all connections, turn on water and check for leaks. I) Re-inst[...]

  • Page 7

    5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open. Remove the circuit board cover plate to expose the cir cuit board. Remove the round, black[...]

  • Page 8

    6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp. SYMPTOM POSSIBLE CAUSES REMEDY PRESSURE DROP • the sediment pre-filter is clogged • replace filter cartridge with appropriate five micron cartridge, Note: check source water supply as fluctu[...]

  • Page 9

    7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source. Check connection and reconnect lamp. • Ballast has switched off. [...]

  • Page 10

    8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life. • Clean s[...]

  • Page 11

    9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .) DP750 RET AINING NUT PLUG SP-3/8 3/8” DRAIN PLUG SP008 QUARTZ SLEEVE SPRING S[...]

  • Page 12

    10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.0 m 3 / Hr .) R-Can Standard 30 mJ/cm 2 56.8 lpm (15 gpm) (3.4 m 3 /Hr .) 56.8 lpm [...]