Standard Horizon DS41 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Standard Horizon DS41, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Standard Horizon DS41 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Standard Horizon DS41. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Standard Horizon DS41 should contain:
- informations concerning technical data of Standard Horizon DS41
- name of the manufacturer and a year of construction of the Standard Horizon DS41 item
- rules of operation, control and maintenance of the Standard Horizon DS41 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Standard Horizon DS41 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Standard Horizon DS41, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Standard Horizon service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Standard Horizon DS41.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Standard Horizon DS41 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DS41 Digital Depth Sounder Owner’ s Manual Standard 2 Inch Installation Dual Station Operation NMEA Repeater Reads in Feet Fathoms or Meters Adjustable Prop or Surface Offset Shallow and Deep alarms Dual Station Operation[...]

  • Page 2

    DS41 Owner’s Manual DS41 Owner’s Manual DS41/HS/2G Contents Specifications ................................................................................................................. 2 Operation ...................................................................................................................... .. 3 Alarms ..............[...]

  • Page 3

    DS41 Owner’s Manual 2 Specifications • Size Mount 2" (51mm) diameter hole Depth behind face plate 3.75" (95mm) max. Display 3-character LCD • Color Black with texture on bezel. • Backlighting Red colored diffused lighting for displa y . • Water Integrity F ront will withstand direct water spra y . • Depth/Alarm Range 2.0 ! 600[...]

  • Page 4

    DS41 Owner’s Manual 3 Operation Whenever power is applied the depth sounder is active and water depth is displayed. If the sonar signal does not show a bottom the display will indicate “- -”. This can occur if the water is aerated or the maximum depth is exceeded. Note: The maximum depth decreases as boat speed increases. Alarms T wo types of[...]

  • Page 5

    DS41 Owner ’ s Manual 4 Deep Alarm T o set the deep alar m: 1. Press the # ke y for three seconds. The display will show: dAL OFF OFF ON ^ V V 2. After two seconds the display will indicate the current Deep Alarm depth setting. 8 8 50 3. Use the " and # keys to change the value. If either key is held depressed for more than one second the re[...]

  • Page 6

    DS41 Owner ’ s Manual 5 4. Use the " and # keys to change the value. If either key is held depressed for more than one second the reading will increase or decrease rapidly . 5. The offset can be programmed in 0.1 unit steps from -9.9 ! 9.9 feet (or equivalent). When programmed f or a negative offset, ‘ - ’ will be indicated on the left h[...]

  • Page 7

    DS41 Owner ’ s Manual 6 T roubleshooting No display: 1. Check DC po wer connections and DC polar ity with voltmeter . 2. Check fuse. No depth reading ( ## ## ## ## ## ) at all depths: 1. Check transducer for growth or multiple coats of paint. 2. Check the transducer cable for cuts and sharp bends. 3. Check that the transducer connection behind th[...]

  • Page 8

    DS41 Owner ’ s Manual 7 What comes with your Digital Depth Sounder Standard Mounting Bracket ................................................................. With mounting hardware Extension P ower Cord ......................... 6 feet long with quick-disconnect connectors T wist Lock F ace Plate .................................................[...]

  • Page 9

    DS41 Owner ’ s Manual 8 2.75" 2.125" 13 ° Note: All transducers come with 30 feet of cable. Replacement Parts The follo wing par ts may be ordered from the P ar ts Depar tment. T o order , call T oll-free Number: 1-800-487-2788. Square F ace Plate ............................................................ Part Number 568001012A Round[...]

  • Page 10

    DS41 Owner ’ s Manual 9 Installation Face Plate Installation 1. T o install a face plate: a ) Attach the face plate to the front panel of the instrument. b ) T wist the face plate cloc kwise until tight. 2. T o remov e f ace plate, twist it anticlockwise until loose and detach. Instrument Installation The instrument can be easily installed in dif[...]

  • Page 11

    DS41 Owner ’ s Manual 10 6. Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on. The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker . The black lead should be connected to the negative terminal. Figure [...]

  • Page 12

    DS41 Owner ’ s Manual 11 T ransducer Installation Note: The installation of a transducer is a job for a professional boat yard that performs numerous installations. The following is an informational guide- line on the installation of transducers. General Correct installation of the transducer is essential for optimum operation of the instrument. [...]

  • Page 13

    DS41 Owner ’ s Manual 12 Sailboats On sailboats, the transducer should be mounted where the acoustic beam will not be shaded by the keel. A spot forward of the keel is usually best. T ry to find an accessible spot with a minimum deadrise angle. See Figure 4. Powerboats On IO ’ s transducers mounted close to the engine usually yield good results[...]

  • Page 14

    DS41 Owner ’ s Manual 13 RUBBER GROMMET SEAL CAP OIL DEADRISE ANGLE CUT PVC PIPE TRANSDUCER Figure 7. In-Hull Installation In-Hull Installation T ransducer installation inside a solid fiberglass hull ma y degrade perf or mance of depth sounder. Therefore, this type of installation is not preferred over thru-hull and transom installations. Should [...]

  • Page 15

    DS41 Owner ’ s Manual 14 Multiple DS41 instruments can be installed on a single vessel. These instr uments can be connected together and configured to operate in a dual station configuration. One instrument is designated as a master and all other instruments, connected to it, are configured as slav es. The master device is connected to the depth [...]

  • Page 16

    DS41 Owner ’ s Manual 15 4. Continue to hold the # key until the display indicates the current linked/ separate selection. Linked Separate 5. Use the " and # keys to change the selection. 6. T o exit this mode , press and hold both the " and # k eys sim ultaneously . Alternatively , if no keys are pressed f or a period of 5 seconds norm[...]

  • Page 17

    DS41 Owner ’ s Manual 16 The DS41 can be configured to operate as a NMEA repeater . In this mode it will display depth information from any depth sounder outputing DPT or DBT NMEA depth data (no other NMEA depth sentences are supported). Notes: 1 ) The only information displayed from the DPT and DBT sentence is depth below the transducer . The us[...]