SPX Cooling Technologies 600 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of SPX Cooling Technologies 600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SPX Cooling Technologies 600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of SPX Cooling Technologies 600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of SPX Cooling Technologies 600 should contain:
- informations concerning technical data of SPX Cooling Technologies 600
- name of the manufacturer and a year of construction of the SPX Cooling Technologies 600 item
- rules of operation, control and maintenance of the SPX Cooling Technologies 600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SPX Cooling Technologies 600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SPX Cooling Technologies 600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SPX Cooling Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SPX Cooling Technologies 600.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the SPX Cooling Technologies 600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    / Mar le y Class 60 0 Cooling T ower /[...]

  • Page 2

    2[...]

  • Page 3

    3 / Flexibility of Design / Class 600 cooling towers are a dir ect descendent of the Doubleflow ® crossflow tower that was designed and patented by Marley in 1938. In 1957, Marley’ s development of hanging fill, wide indented louvers, and stable FRP velocity-recovery fan cylinders enabled the evolution of that Doubleflow tower into the class[...]

  • Page 4

    4 Fans Marley designed and manufactured fans ar e used on all Marley crossflow towers. The fan selection and fan speed for a given tower are based on tower cell size, system losses, and horsepower requir ements. Depending on fan size, blade material is FRP (fiber reinfor ced polyester), GRE (glass reinfor ced epoxy), or cast aluminum alloy . Abov[...]

  • Page 5

    5 Geareducer The Marley Geareducer ® has become the standar d by which all other cooling tower fan speed reducers are judged. Numer ous reduction ratios ar e available so that horsepower is applied at optimum fan speed. The specific Geareducer selection is based on fan speed and horsepower requir ements up to 300 hp per fan. Marley Geareducers ar[...]

  • Page 6

    6 Class 600 splash fill bars are available in the following materials: • PVCin“Omega”,“Mega”or“Alpha” configurations. • Injection-moldedpolypropylene“Ladder”  configurations. • Roughsawn,preservative-tr eatedwood “G” configurations. Each cooling tower application is[...]

  • Page 7

    7 Piping Although side inlet piping is provided as standar d, Class 600 towers are adaptable to end inlet piping. This is an economical method requiring only one riser for each series of hot water basins, regar dless of the number of fan cells. Cast iron, steel, and r einforced plastic pipe ar e all available. / W at er Distr ibution Syst em / Valv[...]

  • Page 8

    8 / Dr ift Eliminat ors / Marley towers utilize Marley XCEL ® plus drift eliminators, a cellular , labyrinthine design which improves drift elimination by several orders of magnitude over that achievable by blade-type eliminators. Significantly lower pressur e losses also reduce fan horsepower requir ements. XCEL eliminators are thermoformed PVC [...]

  • Page 9

    9 The diagonals brace the structure and carry loads to heavy-duty , hot dip glavanized anchor castings. The anchor castings transmit wind and/or earthquake loads from the structur e directly into the foundation. For standard wind load conditions, anchor bolts ar e requir ed only at the perimeter . Structural ceramic rings or glass reinfor ced nylon[...]

  • Page 10

    10 / Casing / The endwalls of Class 600 towers are cased fr om the fan deck level to below the top of the basin curb with 8 oz/sq ft corrugated FRP sheets. FRP is waterproof and corrosion pr oof, is immune to biological deterioration, and requir es no maintenance. Sheets are installed on maximum 4 ′ -0 ″ spans with corrugations running horizont[...]

  • Page 11

    11 Endwall Derrick The endwall derrick is a permanently installed tripod device of galvanized structural steel. In service, removable structural aluminum tracks are positioned acr oss the platform opening. Equipment to be handled is placed on a 4-wheel dolly—part of the equipment handling package—rolled onto the track and elevated slightly . Th[...]

  • Page 12

    SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project. Her e is a partial listing of the additional services offer ed by SPX Cooling T echnologies to help you do your job most effect[...]