SOSpenders 24MSPT-1 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of SOSpenders 24MSPT-1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SOSpenders 24MSPT-1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of SOSpenders 24MSPT-1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of SOSpenders 24MSPT-1 should contain:
- informations concerning technical data of SOSpenders 24MSPT-1
- name of the manufacturer and a year of construction of the SOSpenders 24MSPT-1 item
- rules of operation, control and maintenance of the SOSpenders 24MSPT-1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SOSpenders 24MSPT-1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SOSpenders 24MSPT-1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SOSpenders service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SOSpenders 24MSPT-1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the SOSpenders 24MSPT-1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DO NOT REMOVE PRIOR T O SALE! OWNER’S MANUAL for Model 24MSPT -1 APPROV AL CONDITIONS AND CARRIAGE REGULA TIONS This inflatable PFD is approved by the U.S. Coast Guard for use as a T ype III Personal Flotation Device (PFD). It is not approved for water skiing or other high impact, high speed activities. This inflatable PFD was designed to be more[...]

  • Page 2

    2[...]

  • Page 3

    3 SPECIFICA TIONS Chest Size : 30 - 52 inches (76 - 132 cm) Weight Range : More than 80 pounds (36 kg) Age Range : 16 years of age and older Buoyancy (minimum ): 22.5 Pounds (100 Newtons) when fully inflated Inflation System : Manual Inflation Mechanism (located on your right side) Oral T ube - (located on your left side) Jerk to Inflate T ab - (lo[...]

  • Page 4

    4 II. INSTRUCTIONS FOR USE A. PRE-DONNING INSTRUCTIONS CHECK THE FOLLOWING BEFORE USING THIS PFD: 1. INSPECT PFD FOR DAMAGE 2. BE SURE A CYLINDER IS INSERTED INT O THE MECHANISM AND CYLINDER SEAL INDICA TOR IS GREEN READ BELOW FOR MORE DET AILED INFORMA TION! 1. Inspecting Y our PFD For Damage Make sure that the PFD is free from rips, tears or punc[...]

  • Page 5

    5 c. CO 2 Cylinders are made with a protective coating that may wear off after a period of use or exposure to the environment. When this coat ing is worn off, the CO 2 Cylinder may start to show some signs of rusting. If this occurs, replace the CO 2 Cylinder . d. If a gram scale (such as a postal scale) is available, it is recommended to weigh the[...]

  • Page 6

    6 3. COLD INFLA TION - Oral Inflation may be required in addition to ma nual inflation if chamber is not firm due to cold temperatures at or below 40° F (4°C). Inflation T ime using CO 2 gas will be longer at these temperatures. See FREEZING TEMPERA TURES on page 7. 4. OTHER INFLA TION PRECAUTIONS a. CAUTION - Do not fully inflate orally then man[...]

  • Page 7

    7 G. OTHER USE GUIDELINES 1. Always wear your PFD when underway unless you are inside a cabin. 2. If you need to jump from any height always fold arms over your chest to keep the PFD in place when entering the water . 3. Avoid all unnecessary activities that will be abrasive to the device. 4. Use extreme caution around sharp objects. 5. Avoid unnec[...]

  • Page 8

    8 Cleaning - Damp wipe only with mild detergent recommended for s yn thetic fabrics. Remove grease and oil immediately . Always rinse well with fresh water . Read instructions provided on the device. • DO NOT MACHINE W ASH • DO NOT MACHINE DR Y • DO NOT DR Y CLEAN • DO NOT USE SOL VENT BASED CLEANERS • DO NOT BLEACH C. INSPECTION Certifie[...]

  • Page 9

    9 IV . IS YOUR PFD IN GOOD AND SER VICEABLE CONDITION? Check your PFD between outings to be sure that it is properly armed; that it is free of rips, tears or holes; that all seams are securely sewn; and that the fabric, straps and hardware are still strong. Inspect the inflatable portion of the PFD in accordance with Care and Maintenance Instructio[...]

  • Page 10

    10 HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLA TOR? 1. T o test your inflatable PFD, you will need: • Y our fully armed PFD , and • Rearming kit approved for your PFD. 2. Put on the PFD. 3. Actuate the inflation system by jerking firmly downward on the Jerk to Inflate tab. The PFD should fully inflate within 5 seconds. 4. Get into shallow w[...]

  • Page 11

    11 HOW DO YOU TEST YOUR PFD USING THE ORAL INFLA TOR? 1. T o test your inflatable PFD, you will not need any spare parts or rearming kits . 2. Remove the CO 2 cylinder , to prevent inadvertent activation of the manual inflation system which could potentially damage the PFD. 3. Put on the PFD. 4. Get into shallow water , just deep enough that you ca[...]

  • Page 12

    12 VIII. HYPOTHERMIA Prolonged exposure to cold water causes a condition known as hypothermia - a substantial loss of body heat, which leads to exhaustion and unconsciousness. Most drowning victims first suffer from hypothermia. The following chart shows the effects of hypothermia: PFDs can increase survival time because they allow you to float wit[...]

  • Page 13

    13 Some Points to Remember About Hypothermia Protection: 1. Always wear your PFD. Even if you become incapacitated due to hypothermia, the PFD will keep you afloat and greatly improve your chances of rescue. 2. Do not attempt to swim unless it is to reach a nearby craft, fellow sur- vivor , or a floating object on which you can lean or climb. Swimm[...]

  • Page 14

    14 5. Do not alter your PFD. If it doesn’t fit properly , get one that does. An altered device is no longer Coast Guard approved. 6. Y our PFD is not intended for use as a fender or kneeling pad. 7. If your PFD is wet, allow it to dry thoroughly before storing it. Store it in a well-ventilated area. 8. Do not dry your PFD in front of a radiator o[...]

  • Page 15

    15 1 2 3 4 1. Lay device out flat with yellow inflatable chamber , arrows side, up. 2. Fold left side of chamber under and fold again. Wrap Oral T ube Access T ab around Oral T ube with a portion of the tab left outside of the device. Refer to Figure 3 for more detail. Secure V elcro ® Strips. Fold right side of chamber under and fold again. Secur[...]

  • Page 16

    16 Halkey-Roberts V86160 Manual Inflator ReArming/Status Indicator Instructions DISASSEMBL Y (see figure) Step 1 : Unpack or open the life vest so that the manual inflator is visible. Step 2 : Remove gas CO 2 cylinder by rotating cylinder counterclockwise then pull out. Discard cylinder . REARMING Note: Rearming must follow the sequence below . Ste[...]