Sony VPL-VW85 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sony VPL-VW85, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sony VPL-VW85 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sony VPL-VW85. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sony VPL-VW85 should contain:
- informations concerning technical data of Sony VPL-VW85
- name of the manufacturer and a year of construction of the Sony VPL-VW85 item
- rules of operation, control and maintenance of the Sony VPL-VW85 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sony VPL-VW85 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sony VPL-VW85, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sony service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sony VPL-VW85.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sony VPL-VW85 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    VIDEO PROJECTOR VPL-VW85 PROTOCOL MANUAL 1st Edition[...]

  • Page 2

    VPL-VW85 ! W ARNING This manual is intended f or qualified ser vice personnel only . T o reduce the risk of electr ic shock, fire or injury , do not perf or m any ser vicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! W ARNUNG Die Anleitung ist nur [...]

  • Page 3

    1 (T) VPL-VW85 Table of Contents 1. Overview 1-1. Introduction ........................................................................ 1 1-2. Glossary of Terms .............................................................. 1 1-3. Protocol Stack Structure .................................................... 1 2. Common Commands 2-1. Sub Commands ..[...]

  • Page 4

    [...]

  • Page 5

    1 VPL-VW85 1. Overview 1-1. Introduction The projector is remotely controllable over RS-232C. It is useful for setting up the projector away from the operator. This protocol manual describes the specifications such as packet format and procedures for controlling the projector. In the following sections below, the term “CONTROLLER” is used as a [...]

  • Page 6

    2 VPL-VW85 2. Common Commands 2-1. Sub Commands Sub Command is the value which is used by Simplified Command. Value is assigned for executing function. For example, if you want to change the picture mode, the appropriate value assigned for the desired picture mode should be chosen. <Table 1> <Table 2> Remarks Item Number Data Item Upper[...]

  • Page 7

    3 VPL-VW85 <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte Advanced Iris 00h 1Dh Off 0000h Set/Get Manual 0001h Auto1 0002h Auto2 0003h Real Color Processing 00h 1Eh Off 0000h User1 0001h User2 0002h User3 0003h Film Mode 00h 1Fh Off 0000h Auto1 0001h Auto2 0002h Gamma Correction 00h 22h Off 0000h Gamma[...]

  • Page 8

    4 VPL-VW85 <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte User Gain Red 00h 50h Set Value FFE2h to 001Eh ( _ 30 to 30) Set/Get User Gain Green 00h 51h Set Value FFE2h to 001Eh ( _ 30 to 30) User Gain Blue 00h 52h Set Value FFE2h to 001Eh ( _ 30 to 30) User Bias Red 00h 53h Set Value FFE2h to 001Eh ( _ [...]

  • Page 9

    5 VPL-VW85 Table 2-3 ITEM List For Setup <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte Input 00h 01h Video 0000h Set/Get S Video 0001h Input A 0002h Component 0003h HDMI1 0004h HDMI2 0005h Picture Muting 00h 30h Off 0000h On 0001h Input-A Signal Sel 00h 32h Auto 0000h Computer 0001h Component 0002h Vi[...]

  • Page 10

    6 VPL-VW85 Table 2-5 ITEM List For Infrared Remote Command <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote 17h Refer to the 00h 00h Set Only Command section 2-1-2 * 1 . (15 bit category) (Table 2-6 - _ Table 2-9) Infrared Remote 19h Refer to the 00h 00h Command section 2[...]

  • Page 11

    7 VPL-VW85 2-1-2. Infrared Remote Command Code Tables are shown per function category. . 15 bit PROJECTOR: Table 2-6-Table 2-9 . 20 bit PROJECTOR-E: Table 2-6-Table 2-9 . 20 bit PROJECTOR-EE: Table 2-10 Table 2-6 Infrared Remote Command Code For Picture CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E O_ 05 MOTION ENHANCER TOGGLE O_ 07 BLACK [...]

  • Page 12

    8 VPL-VW85 Table 2-7 Infrared Remote Command Code For Screen CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E O_ 47 PITCH O_ 48 SHIFT _O 60 APA _O 61 PHASE _O 62 LENS ZOOM _O 63 LENS SHIFT _O 64 LENS FOCUS _O 6E WIDE MODE TOGGLE Table 2-8 Infrared Remote Command Code For Setup CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E O_ 15 POWER[...]

  • Page 13

    9 VPL-VW85 Table 2-9 Infrared Remote Command Code For Installation CATEGORY Code Name 15 bit 20 bit PROJECTOR PROJECTOR-E _O 00 V KEYSTONE + _O 01 V KEYSTONE _ _O 02 LENS SHIFT ← _O 03 LENS SHIFT → _O 3A V KEYSTONE _O 78 LENS TOGGLE Table 2-10 Infrared Remote Command Code for 20 bit PRJECTOR-EE CATEGORY Code Name 20 bit PROJECTOR-E O 6E OPTIONS[...]

  • Page 14

    10 VPL-VW85 2-2. Reply <Table 3> Item Number Data Item Data Upper byte Lower byte ACK Complete 00h 00h NAK Undefined Command 01h 01h Size Error 04h Select Error 05h Range Over 06h Not Applicable 0Ah Check Sum Error F0h 10h Framing Error 20h Parity Error 30h Over Run Error 40h Other Comm Error 50h Error description Check Sum Error A check sum [...]

  • Page 15

    11 VPL-VW85 3. RS-232C 3-1. Connection Communication is enabled by the use of a D-Sub 9 Pin cross (reverse) cable. The pin assignment of D-Sub 9 Pin and D-Sub 25 Pin is as follows. Pin numbers indicated as D-Sub 25 Pin are not used. Assured cable length: 15 m (However, assurance may not be applicable for some cables.) The software for controlling t[...]

  • Page 16

    12 VPL-VW85 3-3. Communication Procedure 3-3-1. Outline of Communication All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the command block format. Communication is started by the issue of a command at CONTROLLER and ended when the return data is sent to CONTROLLER after DEVICE receives the command. CONTROLLER [...]

  • Page 17

    13 VPL-VW85 3-6. Command Block Format The block format of Simplified Command for RS-232C as shown in the Fig. 1-1. In this section, the block format for Simplified Command is provided. 3-6-1. Simplified Command [Send] The block format for sending request is shown below. [Receive (without data)] The block format for response which includes no return[...]

  • Page 18

    14 VPL-VW85 3-7. Packet Examples 3-7-1. Change “Wide Mode” to “Zoom” START CODE = A9h ITEM NUMBER = 0020h (Wide Mode) SET/GET = 00h (SET) DATA = 0003h (Zoom) CHECK SUM = 23h END CODE = 9Ah You will receive the packet below if the process is successfully completed. START CODE = A9h ACK/NAK = 0000h (Complete) ACK = 03h DUMMY DATA = 0000h CHEC[...]

  • Page 19

    VPL-VW85 The material contained in this manual consists of inf or mation that is the proper ty of Sony Cor poration. Sony Corporation e xpressly prohibits the duplication of any portion of this manual or the use thereof f or any purpose other than the operation or maintenance of the equipment described in this manual without the e xpress written pe[...]

  • Page 20

    Printed in Japan Son y Cor poration 2009. 9 16 ©2009 VPL-VW85 (CN) VPL-VW85 (J) VPL-VW85 (SY) VPL-VW85 (U) E 9-968-691-01[...]