Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 should contain:
- informations concerning technical data of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8
- name of the manufacturer and a year of construction of the Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 item
- rules of operation, control and maintenance of the Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Schneider Optics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Schneider Optics PC-SUPER-ANGULON 28 mm f/2.8 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Schneider Optics Inc  285 Oser A venue Hauppauge · NY ¡¡788 · USA Phone 63¡76¡ 5000 Fax 63¡76¡ 5090 inf o@schneideropticscom www schneideropticscom Exclusiv e distributor f or the USA PC-SUPER - ANGUL ON 28mmf /2. 8 UserManual[...]

  • Page 2

    2 ListofContents Name of Parts and Cross Section of the Lens  3 General Description ?[...]

  • Page 3

     3 1 0,7 0,5 0,4 0,35 0,3 5 3 2 1 ,5 1 ,25 1 8 5,6 4 2,8 4 8 1 6 22 P C - S U P E R - A N G U L O N NameofPartsandCrossSectionoftheLens Focusing ring Distance scale Depth of eld scale Aperture scale Aperture setting ring Pre-set aperture setting lever Shifting knob Index Knurled ring Camera mount Fixing screw f or came[...]

  • Page 4

     8 3 1 0,7 0,5 0,4 0,35 m o o 5,6 11 4 16 2,8 22 22 4 8 4 8 16 1 6 22 5 3 2 1 ,5 1 ,25 8 3 1 0,7 0,5 0,4 0,35 m o o 5,6 11 4 16 2,8 22 22 4 8 4 8 16 1 6 22 5 3 2 1 ,5 1 ,25 GeneralDescription Not shifted Maximally shifted The SCHNEIDER PC-SUPER-ANGUL ON 28 mm f /2 8 is a very high- quality wide- angle lens f or 35 mm analog and digital SLR[...]

  • Page 5

     GeneralDescription V er tical shift is the most popular : upward, especially when photographing high buildings, so that the camera does not have t o b e tilted upward; and down ward f or product shots at an oblique angle or also f or shots fr om high locations such as tow ers or mountains so that the camera do es not hav e to be tilted downw[...]

  • Page 6

    6 P ersp ec tiveCorrectionf or AnalogandDig it alPhotogr aphy 8 3 1 0,7 0,5 0,4 0,35 m oo 5,6 11 4 16 2,8 22 22 4 8 4 8 1 6 16 22 5 3 2 1,5 1,25 Horizon T oo much foreground Optical axis Building is true to scale but cropped on top 8 3 1 0 , 7 0 , 5 0 , 4 0 , 3 5 m o o 5 , 6 1 1 4 1 6 2, 8 22 2 2 4 8 4 8 16 16 2 2 5 3 2 1 , 5 1 , [...]

  • Page 7

     P ersp ec tiveCorrectionf or AnalogandDig it alPhotogr aphy T oo low T oo wide 8 3 1 0,7 0,5 0,4 0,35 m oo 5,6 11 4 16 2,8 22 22 4 8 4 8 1 6 16 22 5 3 2 1,5 1,25 Horizon Optical axis Building is true to scale and completely reproduced V ertical lines are parallel V ertical shift of 7 mm es the sharpness, produces just visible [...]

  • Page 8

    8 L arg eImag eCir clef orLensShiftsupto1¡mm The PC-SUPER-ANGUL ON 28 mm f/2 8 already pr oduces an ex ceptionally attened image at f ull aper ture within the 62 mm image cir cle which is thus twice as large in area r elative to the image cir cles of other 35 mm lenses Sharpness and contrast are incr e ased furt[...]

  • Page 9

     L arg eImag eCir clef orLensShiftsupto1¡mm Natural size max. ¡¡ mm max. ¡0.5 mm max. 9 .5 mm I m a g e c i r c l e 4 4 m m I m a g e c i r c l e 6 2 m m entation can alwa ys be chosen, e  g irrespective of the shift dir ection with the knob at the bottom with f ree hands, or rather at the top at the tripod?[...]

  • Page 10

    ¡0 Fixin gandRemo vin gtheLens The lens is available in a connection sock e t to mat ch differ ent 35 mm SLR camera systems and is inserted int o the camera b ay onet or thread f or fas- tening t o the camera such that the red dot on the connection so ck e t is op- posite the corr esp onding marking on the camera T o lock the lens i[...]

  • Page 11

    ¡1 Par allelShift The lens is shifted perpendicular to the optical axis relativ e to the ba yonet mount and so also relativ e to the taking f ormat by rotating a knurled shift - ing knob at a shaft which is elastically e xible to pr otect against its damage or injury to the user  The lens tube can be rotated continuously t o the left or t[...]

  • Page 12

    ¡2 Focusin gandDepthofField The f o cusing of wide- angle lenses appe ars to be r elatively non-critical due to their large depth of eld How ever , caref ul focusing is actually necessary to utilize the high imaging quality of this lens t o the full T o ensure maxi- mum brightness of the f ocusing screen and the best recogniti[...]

  • Page 13

    ¡ If the measurement is not carried out using a separate hand e xposure me- ter , but using the TT L exposure meter int egrated in the camera, it is neces - sary to measureinthecenteredposition of the parallel shift while st op- ping down to the w or kingaperture because the arrangement and align- ment of the measuring cell of al[...]

  • Page 14

    ¡ Filters,LensHoodandCameraMounts Only the ov ersized B + W W A lters of the size 67 EW can be used with the SCHNEIDER PC-SUPER -ANGUL ON 28 mm f/2 8 due to the extreme- ly large image angle utilized at maximum shift up t o 93 4° The follo wing table shows the order n umbers of the most popular lter types – furt[...]

  • Page 15

    ¡ Filters,LensHoodandCameraMounts Wide-angleltersofsize6EW Or derno. B+ W UV Filter with MR C coating                                40295 B+ W Skylight lter MR C coating          ?[...]

  • Page 16

    ¡6 Specications Relativ e ap erture                          ¡: 2 8 Eff ective f ocal leng th                       292 mm Nodal point separation HH'           [...]